Download:
pdf |
pdfOccupational Safety & Health Administration
Nationally Recognized Testing Laboratory Program
Application Guidelines
US Department of Labor
Occupational Safety and Health Administration
Directorate of Technical Support
Overview
The NRTL Program
Occupational Safety & Health Administration (OSHA) safety standards require that specified equipment
and materials (products) be tested and certified for safety by an OSHA-recognized organization. OSHA’s
Nationally Recognized Testing Laboratory (NRTL) Program fulfills this responsibility by recognizing the
capabilities of (mainly) private sector testing organizations to test and certify such products for
manufacturers. The NRTL Program, in operation since 1988, is an effective public and private
partnership. Rather than performing testing and certification itself, OSHA relies on private sector
organizations to accomplish it. This helps to ensure worker safety, with existing private sector systems
performing the work rather than maintaining government facilities.
These organizations use generally accepted, consensus-based product safety standards issued by national
standards-producing organizations such as:
•
•
•
•
American National Standards Institute (ANSI)
American Society for Testing Materials (ASTM)
Factory Mutual Research Corporation (FMRC)
Underwriters Laboratories (UL)
Product Categories
OSHA requires testing for certain products in its standards found in Part 1910 of Title 29, Code of
Federal Regulations (29 CFR Part 1910) (see reference pages). Thirty-seven broad categories (see table
of categories) of products are covered, including:
• Electrical equipment
• Fire detecting and extinguishing equipment
• LPG gas utilization equipment
• Equipment used in potentially hazardous locations
The Meaning of Product Certification
A product certified by a Nationally Recognized Testing Laboratory has met consensus-based standards
for safety. Users of that product are thereby assured that the certifying NRTL monitors the product and
the process of its manufacture for quality assurance. The NRTL Program, in turn, assures that the
organizations certifying the safety of the products are qualified to do so.
Eligibility
To be recognized, an organization must meet OSHA’s requirements. Initial recognition, valid for 5 years
and for a specific scope of recognition, is granted if the application and an on-site review of the
organization demonstrate the applicant is completely independent, has the capability (including
equipment, personnel, and quality assurance), and meets other requirements to test and certify products
for safety. An organization must have the necessary capability both as a testing laboratory and as a
product certification body to receive OSHA recognition as an NRTL. In addition, for foreign-based
applications, OSHA must consider “reciprocity” of the foreign government. Once recognized, OSHA
reviews each NRTL’s activities to assure it continues to comply. Also, the NRTL can request an
expansion of its recognition. The initial renewal of recognition is based upon a renewal application and
may require an on-site review.
Program Regulations, Policies, and Procedures
Program requirements and criteria are explained in OSHA Regulations 29 CFR 1910.7 and the NRTL
Program Directive.
Program Fees
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 1
Overview
You must pay some fees at time of application. OSHA does not process and may return an application if
it does not receive the applicable fees. OSHA bills you for the remainder of the application fees. Once
recognized, you generally pay fees each year. The Fee Schedule and the Fee Payment Instructions and
Information documents detail the amount that you must pay and when and where to pay the fees. You
may obtain these documents by contacting OSHA at the address or phone number listed below or through
the program’s web page, also listed below. Fees for the NRTL Program went into effect on October 1,
2000.
Confidentiality
The name of an applicant seeking recognition becomes public information at the time OSHA publicly
announces its preliminary finding on an application. In addition, all documents and other information in
an application become public information when submitted unless: (1) particular items are specifically
designated as confidential or (2) OSHA determines particular information appears to be confidential.
However, neither of these two conditions guarantees confidentiality. If either condition applies, OSHA
will provide an applicant or NRTL an opportunity to object to disclosure of the information. For more
information, see 29 CFR Part 70, “Production and Disclosure of Information or Materials.”
Information
If you have questions about the NRTL Program or these guidelines, or would like to receive more
information or guidance in completing an application, please call 202-693-2110.
Send completed applications, amendments to applications, or other correspondence to:
Director
Office of Technical Programs and Coordination Activities
NRTL Program
Occupational Safety and Health Administration
US Department of Labor
200 Constitution Avenue NW, Room N3653
Washington, DC 20210
On the Web
Application and general information is available by selecting “Programs” or “Subject Index” in
http://www.osha.gov.
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 2
How OSHA Processes an NRTL Application
The regulations for the NRTL Program require that organizations applying for an initial recognition by
OSHA as an NRTL, or for an expansion or a renewal of its recognition provide sufficient information and
detail in its application to demonstrate that it meets the requirements and criteria for recognition,
expansion, or renewal. This application guidelines provides an appropriate basis for the review,
determination, and evaluation of the qualifications of the organization applying for recognition under the
Program. The applicant is not required, but is strongly encouraged, to submit all the information
requested in the formats shown.
When an organization submits its application materials, OSHA staff thoroughly reviews those materials
for completeness and adequacy. For applications from foreign-based organizations, OSHA must consider
the “reciprocity” of the foreign government (as described in I.A of Appendix A in 29 CFR 1910.7).
When the NRTL Program staff determines that the application is complete and adequate, the staff perform
an in-depth on-site review of the applicant’s organization, programs, and facilities. If certain criteria are
met (see NRTL Program Directive), an on-site review may not be necessary.
Based upon the information obtained primarily through the on-site review, the staff prepares a report and
recommendation. The report and the application provide the main basis for a preliminary finding on the
application. OSHA publishes a notice of this finding in the Federal Register to allow for public comment.
Following a 30 (formerly 60)-day comment period, OSHA must publish a final decision and response to
comments in the Federal Register. Publication makes the recognition official for successful applicants
and officially denies the recognition for unsuccessful applicants. A formal notification from the Assistant
Secretary of Labor for Occupational Safety and Health (OSH), the head of OSHA, is sent to successful
applicants. The terms of the recognition are set forth in this formal notification as well as in the final
Federal Register Notice.
The chart below indicates the steps in this application process.
1. OSHA staff
provides
information and
application
package in
response to a
request from an
organization
4. OSHA staff
prepares report
and
recommendation,
and prepares
notice of OSHA’s
preliminary
decision. After
approval is given
by the Assistant
Secretary, the
notice is published
in the Federal
R i t
2. Applicant
completes and
submits application
with supporting
materials
3. OSHA staff
reviews
application,
discusses it with
the applicant, and
conducts on-site
review of
laboratory sites, if
needed
5. After the end of
the 30-day comment
period, OSHA staff
reviews /resolves
public comments and
prepares notice of
OSHA’s final
decision. After
approval is given by
the Assistant
Secretary, the notice
is published in the
Federal Register.
6. When the final
notice is published,
the initial
recognition, or the
expansion or
renewal of
recognition
becomes official. A
formal notification is
then sent by the
Assistant Secretary
to the NRTL
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 3
Instructions for Completing the NRTL Application
Provide information for every item contained in each part of the application, even if only to provide
proper references or to note that it is not applicable. Information and documents you provide for your
application must be in English unless otherwise accepted by OSHA. You may either submit hard copy of
the application or complete the application on diskette, using WordPerfect, Word, or other compatible
word processing programs. If the application is completed on diskette, insert the text of your information
in the appropriate spaces following each item. Then submit a signed hard copy of the General
Application Information, with the diskette and copies of any attachments. If submitting your application
in hard copy, provide your information on a separate attachment. Then, submit the application along with
any hard copies of attachments. Send application and a cover letter to the address shown in the Overview
section. Contact the NRTL Program staff if you have any questions. Note: OSHA will formally accept
your application, and then schedule an on-site review, only when it has determined that the
application is complete and the information provided is adequate. At that time, OSHA may request,
and you will need to provide, two more copies of the complete application.
General Application Information
Provide all information requested. Attachments should be numbered and labeled, referencing the
numbering on the General Application Information sheet. The legal signatory must sign in the space
provided.
Applicable Test Standard(s)
• Complete one sheet for each product safety test standard for which recognition is sought. Other
formats may be used if the same or equivalent information is provided. Do not submit a copy of the
actual test standard. If the test standard is not readily available to OSHA, Program staff will ask you
to provide a copy of the standard. You should apply for all test standards for which you may qualify
at the time of application.
• The test standard must meet the criteria for an “appropriate test standard” in 29 CFR 1910.7(c).
• If the test standard has been issued by an organization other than ANSI, ASTM, UL, or FM, please
submit documentation assuring compliance with 29 CFR 1910.7 (c)(1), (c)(2), and (c)(3).
• The scope of the test standard must pertain to products covered under the NRTL Program.
Detailed Application Information/Evaluation Criteria
Provide information for every item under each of the categories. Each category represents a critical
component, of the requirements for recognition, that OSHA must review and evaluate.
Complete Application
In order for your application to be complete, it must include the General Application Information,
Applicable Test Standards and Detailed Application Information/Evaluation Criteria, or equivalent
information, and the following supplements:
¾Organizational chart(s) (for overall organization and, if applicable, each major unit or location) that
depicts owners, directors, and officers, and shows areas involved in the NRTL operations
¾Position descriptions/responsibilities and resumes of key personnel involved in the NRTL operations
¾Listing/labeling, qualification and follow-up inspection procedures; sample of agreement(s) for
certification
¾Sample(s) of test data sheets & testing procedures, test/evaluation report procedures for NRTL
operations, test and calibration equipment listing for each site
¾Calibration program manual (including samples of specific calibration procedures) or equivalent
¾Identification number or verification of registration of certification mark(s) with the US Patent and
Trademark Office (USPTO), or evidence of application for registration with the USPTO
¾Quality manual (covering both test laboratory and certification organization operations); related
detailed quality assurance procedures or appropriate samples
¾Detailed standard operating procedures (including work instructions) for testing and certification
operations or appropriate samples
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 4
Instructions for Completing the NRTL Application
¾Certificate of Incorporation or proof of applicant’s legal existence, pertinent by-laws or articles
Attach any other documents requested or that will assist the OSHA staff in better assessing your
application. Any additional documents submitted should be for illustration or clarification, and not in lieu
of the information requested. In addition, clearly label and reference each attachment to the application
itself.
Expansion and renewal of recognition
After receiving its recognition, an NRTL may submit requests to expand its scope of recognition to
include additional standards or sites, or to use the “supplemental” programs described in the March 9,
1995 Federal Register notice. Also, at the end of the initial five-year recognition period, an NRTL must
request a renewal of its recognition. Please complete and submit the following documents to apply for
an expansion or for a renewal. Send all information to the address shown in the Overview page.
Requesting an expansion of recognition
•
Complete any of the sections 1 through 10 of the General Application Information, if not
previously submitted or to reflect major changes since the date of the most recent application, and
sign section 12. Also, complete any applicable sections of the Detailed Application
Information/Evaluation Criteria (DAI/EC) specifically requested below. Include a cover letter, or
only submit a letter to apply if these instructions require no other information.
•
For additional test standards, complete an Applicable Test Standard sheet for each test standard
unless the necessary information has been previously submitted.
•
For an additional site(s), complete the Basic Information portion of the DAI/EC to provide the
necessary information or to identify information previously submitted that will apply. Do not
address the “Independence” section of the DAI/EC unless information was not previously
submitted or previously submitted information has changed. Also, submit an Applicable Test
Standard sheet for each standard to be used for the site(s), and submit any applicable supplements
listed in the “Complete Application” section above.
•
For a “supplemental” program(s), complete the applicable Optional Information of the DAI/EC to
provide the necessary information.
Requesting a renewal of recognition
•
Submit a letter requesting the renewal of recognition. Complete any of the sections 1 through 10
of the General Application Information, if not previously submitted or to reflect major changes
since the date of the most recent application, and sign section 12. Also, complete any applicable
portions of the Detailed Application Information/Evaluation Criteria (DAI/EC) to reflect major
changes since the date of the most recent application.
Amendments
You may amend the application any time prior to publication of the preliminary notice. Submit an
original and 2 copies of amendments unless it is just a letter.
SUPPLEMENTAL INFORMATION:
Program Regulations, Policies, and Procedures
The application shall be prepared in compliance with all applicable requirements in the Program
regulations, policies, and procedures. The Program regulations are 29 CFR 1910.7, which specifies the
requirements an NRTL must meet to be recognized, and specifies the general requirements and process
that OSHA will use to evaluate and recognize an NRTL. The Program policies and procedures are
contained in the NRTL Program Directive, which further details how OSHA will evaluate and recognize
an NRTL, monitor the NRTL’s recognition, and administer aspects of the Program. Additional criteria
are specified in a March 9, 1995 Federal Register notice (60 FR 12980). This notice describes the
“programs,” whereby the NRTL qualifies other organizations to partially test and/or certify products and
to provide support services. The NRTL Program Directive modifies and clarifies portions of this notice.
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 5
Instructions for Completing the NRTL Application
Legal Signatory
The legal signatory signs the application and any amendments. The legal signatory(s) of the applicant is
recognized by OSHA as the individual responsible for submitting the application, and who can legally
bind the applicant to the conditions and requirements for recognition. The legal signatory is the
applicant’s official contact for OSHA. To change the legal signatory, the current legal signatory (or an
individual that can legally bind the organization) sends a letter to OSHA regarding the change.
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 6
General Application Information
Please provide the following information about the applicant’s organization.
1. Legal name of applicant organization
2. Street address
Mailing address (if different)
Telephone and fax numbers
E-mail address and website address, if available.
3. List of owners (with beneficial interests >2%) and percentage of ownership.
4. Name and affiliation of Directors
5. Explanation of complete independence [See policy on Independence in Appendix C of Directive]
6. Name and title of Officers and key staff (and affiliations, if significant)
7. All organizational components, including locations and functions, noting individual sites for which
accreditation is sought
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 7
General Application Information
8. Primary field of testing
9. Summary of Proposed Scope of Recognition (sites, standards, & programs)
10. Legal Signatory and alternate contact person(s) (include phone and fax numbers, and email address if
different from item #2 above)
11. Brief history of company and principal line(s) of business
12. Statement on Terms of Recognition
, the applicant, I attest that all statements and
As legal signatory for
information contained in our application are correct to the best of my knowledge and are made in good
faith. We agree to comply with all the policies, conditions, and requirements for recognition that
OSHA imposes through its regulations, directives, and Federal Register notices of recognition. We
also agree to operate as an NRTL only within our approved scope of recognition (applicable test
standards, sites, & programs), following the policies, procedures, structures, and practices described in
our original or amended application accepted by OSHA, or in appropriate revisions we make after
recognition. We further agree to promptly submit details to OSHA of any major changes in those
operations.
Legal signatory (Type or print Name, then sign and date within the space provided)
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 8
Applicable Test Standard
Complete one for each standard for which recognition is requested. Note: this is a sample format.
Other formats may be used if the same or equivalent information is submitted.
Standard Designation (e.g., ANSI C37.46 or ANSI/UL 22, or FMRC 1110), and Title
Year of Issue or Revision and Approved by (ANSI, ASTM, Other)
Laboratory Site(s) and Address(es) where standard will be used
1. Test Equipment
SECTION* TEST OR MEASUREMENT
TEST EQUIPMENT
AVAILABLE?
2. Test Procedures
SECTION*
LABORATORY TEST PROCEDURES**
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
IN PLACE?
Page 9
Applicable Test Standard
3. Special Apparatus or Facilities
SECTION*
DESCRIPTION OF APPARATUS OR FACILITIES
IN PLACE?
4. Number of products evaluated under this standard at this site: ________________
5. Number of products currently listed under this standard: ____________________
Approved By (Signature, Title, and Date)
(Use additional sheets when submitting in hard copy, if necessary)
* Section refers to the applicable section number of the test standard
** Name/number of in-house test procedure(s) used by the laboratory to perform the tests or satisfy the requirements
specified in the section of the test standard.
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 10
Detailed Application Information/Evaluation Criteria
BASIC INFORMATION
Outlined below are the evaluation categories pertaining to each of the four recognition requirements in 29
CFR 1910.7(b). Under each category are detailed criteria that OSHA will use in evaluating whether the
applicant meets or an NRTL continues to meet the recognition requirements. Provide the necessary
detailed information for each applicable category to explain how the criteria will be met. Include
the policies, procedures, methods, personnel, or practices that are pertinent to meeting the criteria.
If not applicable or information is not available, please so state. If the criteria for one or more categories
is applicable but not fully met, submit sufficient information and detail to clearly demonstrate how you
meet the corresponding requirement(s). The information you provide should be adequate and primarily
related to your planned (if not yet recognized) or actual (if recognized) operations as an NRTL. General
references and cross referencing may be used, where appropriate.
If using a word processing program, insert the text of your information following each criterion or
the list of evaluation criteria for the category. Do not use the space provided for our auditor’s
review and findings. If submitting your application in hard copy, provide your information on a
separate attachment. Provide the OPTIONAL INFORMATION if relevant to the application.
Outline level examples: I. Capability (recognition requirement)
A. Testing Facilities (evaluation category)
3. Adequate measures are taken to ensure good housekeeping. (evaluation criteria)
I. Capability
A.Testing Facilities
1. Accommodations, calibration and test areas required by the test standards are available and adequate
for tests.
2. Access to and control of areas with incompatible activities are defined and controlled.
3. Adequate measures are taken to ensure good housekeeping.
4. Energy sources, lighting, heating and ventilation required by the test standards are available for
calibrations and tests.
5. Facilities required by the test standards are available to monitor, control and record environmental
conditions during tests.
6. Laboratory procedures for handling of test samples address control and monitoring of environmental
conditions, protection from adverse conditions, item inventory, secure storage, and proper tagging or
marking.
7. Laboratory measures and procedures related to security include provisions for: controlling access, off
hours security, and fire protection for the facility; protection of proprietary rights and confidential
information of its clients; informing all personnel of confidentiality and security policies; limiting
distribution of confidential information; limiting access to and safe storage of records (including
certificates and reports); back-up or off-site storage; and designate personnel responsible for monitoring
security.
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 11
Detailed Application Information/Evaluation Criteria
B. Testing equipment
1. Testing equipment is available in the lab to perform tests required by the standards to be used for the
NRTL Program.
2. Records maintained for each item of equipment and all reference materials contain the following, at a
minimum: name of the item, manufacturer's name, type and serial number, date received/placed into
service, current location, condition when received, manufacturers' instructions, dates and results of
calibration and dates of next calibration, details of maintenance carried out and planned, and history of
damage, malfunction, modification and repair.
3. Equipment that has been subjected to overloading or mishandling, or which gives suspect results, is
taken out of service and not used until it has been repaired and calibrated.
4. Written procedures are available for the laboratory to examine effects of defective equipment on
calibrations and tests, and take appropriate action.
5. Equipment is properly maintained.
OSHA auditor’s review & findings:
C. Testing, Evaluation, and Processing Procedures
1. Each test method or procedure has sufficient detail instructions that assure reasonable repeatability of
tests and include or address the: title, effective date, specific test equipment to use, minimum accuracy
requirements, warnings/caution statements to alert the operators of potential hazards, normal and any
unusual ambient conditions (including tolerances) for tests, test data to be obtained and recorded, the
minimum resolution of measurements, objective acceptance criteria for results, testing techniques
(unless obvious), and test operator instructions on equipment operation and on handling and preparation
of test samples (if applicable, including multiple sample marking).
2. Test data sheets or similar documents include the test procedure and standard used, product or
component tested, test equipment used in the test, date of the test, test report number, signature of the
personnel performing the test, the ambient test conditions, and test results.
3. Procedures for developing and maintaining test methods and procedures identify the personnel
responsible for developing, reviewing and maintaining the procedures, specify frequency of review by
management, ensure consistency with recognized standards, ensure that deviations still assure the
product conforms with the standard, and ensure modifications are reviewed by personnel who are
familiar with the standard.
4. Procedures for evaluating test data require the investigator to: verify and use the latest standard
edition, provide written justification of how a product complies with each section of the standard
(including a reference to a test procedure for sections that require tests be conducted), and address
components that are not listed, have a non-standard design, or are tested by a foreign test laboratory.
5. Policies on evaluation of test data identify personnel responsible for technical decisions on the
standard, how to decide which applicable section of a standard applies, how to handle newly developed
technologies when the standard does not apply; require that interpretations of the standards are
documented and made readily available for the appropriate investigators; and require the resolution of
product discrepancies without the lab engaging in the redesign of the product, except to explain the
failures in regard to the product testing standard.
6. Standard operating procedures, related to product testing, evaluation, certification and other
processes, are or will be used in operating as an NRTL.
7. Procedures for processing a certification application identify the steps for the application,
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 12
Detailed Application Information/Evaluation Criteria
administrative/technical processing of the investigation in chronological order, personnel responsible for
each stage of the process, and records maintained at various steps of the process.
8. Procedures for processing require the NRTL to select a product standard for certification, and identify
the steps and criteria for selection, personnel responsible for decision (who are experienced in the
product area), manner of resolving disagreements concerning the applicability of a standard, and manner
of handling products covered by two or more standards.
9. Procedures for developing and maintaining processing procedures identify personnel responsible for
developing, reviewing and maintaining the procedures, the frequency for review, and personnel
responsible for verifying that the procedures are being followed.
OSHA auditor’s review & findings:
D.Calibration Program
1. Persons responsible for the calibration program and authorized to perform each type of calibration are
identified.
2. Calibration intervals are established for each type or item of equipment, and policies and procedures
are in place for extending the calibration of an instrument.
3. Records for each calibration contain sufficient information to permit their repetition.
4. Each item of equipment, including reference materials, is labeled, marked or otherwise identified to
indicate its calibration status.
5. Written procedures are available that address calibrations and reference standards or materials, and
that ensure their traceability to the appropriate standards maintained by the U.S. National Institute of
Standards and Technology (NIST), or if in a foreign country, to equivalent standards or materials
maintained by a nationally or internationally recognized body.
6. Primary standards are appropriately identified and maintained.
7. New, leased, rented, and repaired equipment are calibrated prior to use.
8. Procedures are in place to check calibration and to re-evaluate test results if the calibration interval is
exceeded during tests.
OSHA auditor’s review & findings:
E. Quality Assurance (QA)
1. Quality Manual and quality procedures or documents
· Are readily available to the personnel
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 13
Detailed Application Information/Evaluation Criteria
·
·
·
·
·
·
·
·
Contain a corporate quality policy statement, and provisions for ensuring quality policy are
understood, implemented and maintained
Cover the entire "quality loop" from application for services to final testing or listing of
products including follow-up services
Address how to identify and remedy potential or actual quality problems
Identify how to supplement or revise the Quality Manual
Identify the relationship of quality manuals, laboratory procedures, and other relevant
documents.
Identify the personnel responsible for quality, other general and the specific responsibilities for
quality, and the authority delegated to each activity
Specify the coordination necessary between different activities
Identify the control over activities that affect quality
2. Internal quality audit policies and procedures specify
· The frequency of routine audits, the qualifications and independence of the audit personnel, and
the bases for conducting audits
· The reporting and management review of audit findings, reasons for deficiencies, conclusions,
recommendations on corrective actions, and the effectiveness of corrective actions
· How permanent changes resulting from corrective actions are recorded in standard operating
procedures, instructions, manuals and specifications
3. Audit reports include the name(s) of the auditor(s), the areas audited, the dates of the audit and the
signature of the auditor(s), the discrepancies encountered, corrective action plan (including time for
completion and evidence of implementation), and review by upper management.
4. QA oversight of company owned satellite facilities include routine and documented internal audits of
satellite facility personnel, regular headquarter’s review and audit of the quality assurance program and
audits conducted by satellite personnel, and consistency of technical records and interpretations among
all facilities
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 14
Detailed Application Information/Evaluation Criteria
F. Records (including Standards Library)
1. Policies and procedures for test standards distribution & control identify the: personnel responsible
for maintaining and distributing revised standards, methods to control the distribution of standards,
method to notify all relevant locations, including clients and agents, about modifications or
amendments, and effective date that laboratory clients must comply with the requirements of a modified
standard.
2. Current issues of the appropriate standards are available at all relevant locations and superseded
standards are removed from use throughout the organization, and archived.
3. Records maintained for testing and certification identify the personnel responsible for maintaining
records; specify a retention period for each record, persons authorized to access records, and how to
correct or modify information on a record; and contain information showing the way each certification
procedure was applied, including test/inspection reports.
OSHA auditor’s review & findings:
G.Personnel
1. Sufficient personnel are available with the education, training, technical knowledge and experience
for their assigned functions.
2. Each position description is maintained up-to-date, and specifies the responsibility and limitations,
education, experience, technical knowledge and training needed for the position.
3. Records are maintained on the relevant qualifications, training, skills, and experience of the technical
personnel.
4. Staff are qualified or trained to carry out specific tests, evaluations or calibrations.
5. Staff training is kept up-to-date and staff keep up-to-date of current test standard issues (includes
participation in technical groups or committees).
6. The employee safety program identifies, evaluates, and prevents or controls laboratory hazards.
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 15
Detailed Application Information/Evaluation Criteria
II. Control Programs
A.Listing and Labeling
1. The certification mark used for the NRTL Program is registered with the U.S. Patent and Trademark
Office, or an application for registration has been submitted to the USPTO.
2. The mark is applied to each unit of the product certified, or, if not feasible, to the smallest package,
and test standard(s) to which the unit is certified is shown in the marking.
3. Procedures and resources are in place to properly control the certification mark, to monitor
advertisements, catalogues and brochures for incorrect references or misleading use of its certification,
and to take appropriate corrective actions.
4. Proper controls are in place to assure accuracy of information in the listing book.
OSHA auditor’s review & findings:
B. Follow-up and field inspections
1. Procedures and resources are in place to survey the manufacturer’s products, process and quality
management system, and these procedures identify the frequency of inspections, and the process
involved.
2. Initial assessment of the manufacturing facility checks for controls on the production, on
conformance with specifications, to uniquely identify batches or runs of product, to isolate products in
case of nonconformance, to notify the laboratory if changes in the product, process or quality
management system may affect the product.
3. Initial assessment of the manufacturer’s quality control system checks for the separation of the head
of quality assurance from production, quality audit checks, use of appropriate QC sampling procedures,
independent tests on products using the relevant standards, and inspections and tests conducted by
personnel independent from production.
4. Initial assessment of the manufacturer’s records and documents system checks for periodic updating
of master specifications, production records maintained for an appropriate period of time, control of
specification modifications, and tracking and documentation of product defects, claims and complaints.
5. Initial and follow-up assessment of the manufacturer’s evaluations and tests, required by a test
standard, checks for consistency of procedures with the standard, test equipment properly maintained
and routinely checked by qualified personnel.
6. The initial assessment of the manufacturer is conducted by qualified personnel.
7. Follow-up inspections procedures identify who conducts the periodic follow-up inspections and the
reports and records that must be generated and retained
8. Agents that are used for follow-up inspections have the facilities and qualified staff for adequate
surveillance and routinely report the results of the manufacturer's surveillance.
9. Appropriate contracts, covenants, or agreements are used in providing testing and certification
services to clients and include
· Provision(s) for submitting products for inspection and testing
· Provision(s) for permitting periodic inspections by the applicant
· Provision(s) for permitting samples of product to be selected from production for independent
testing
· Covenants from the client to observe and comply with the applicable standards
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 16
Detailed Application Information/Evaluation Criteria
·
Controls to prevent the client from releasing the products resulting from changes (in the
product, process or quality management system) until the laboratory has notified the client
· Provision(s) for unobstructed access to the manufacturing premises without prior notification
· Provision that the product will be produced to the same specifications as the sample submitted
for initial testing
· Controls to ensure that all quality management system and production records will be open and
readily available for inspection by the laboratory
10. Procedures or agreements are in place to address each of the following situations: instituting a recall,
removing the mark of conformity from products, rebuilding a product so it will comply with the
standard, scrapping or replacing a return part if it is not practical to remove the mark or rebuild the
product.
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 17
Detailed Application Information/Evaluation Criteria
III. Independence
A.There are no organizational affiliations with a supplier or major user of products that an NRTL must
certify, and such products are not supplied (i.e., manufactured or distributed) or used substantially.
B. Significant financing is not provided to a supplier or major user of products that an NRTL must
certify; no significant product design, similar services or products are sold to such a supplier or major
user; and there are no significant investments in either.
C. No supplier or major user of products that an NRTL must certify owns more than two percent (2%) of
the NRTL, and no owner is also a major owner of such a supplier or major user.
D.Significant financing is not received from a supplier or major user of products that an NRTL must
certify, or their major owners.
E. No person holding a substantial position with the NRTL has a significant financial interest in a
supplier or major user of products that an NRTL must certify, or is a director or key personnel of
either.
F. Conflict of interests policies are in place and are followed, and conflict of interests statements are
signed by all personnel.
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 18
Detailed Application Information/Evaluation Criteria
IV. Report and Complaint Procedures (see also follow-up programs section)
A.Reports
1. Test reports include
· Name and address of laboratory, and location where the test was carried out if different
· Unique identification (serial number), page numbers and total number of pages
· Name and address of client
· Description and unambiguous identification of the item tested (complete component list,
supplier, manufacturer, model number, etc.)
· Characterization and condition of the calibration or test item
· Date of receipt of calibration or test item and date(s)of performance of calibration or test
· Calibration or test method, or an unambiguous description of any non-standard method used
· Statement of the estimated uncertainty of the test results, where relevant
· Signature and title (or equivalent) of the person responsible for the content of the report and the
date of issue
· Statement that the certificate or report shall not be reproduced without prior written consent of
the laboratory
2. Procedures for preparing technical reports are written and
· Identify personnel responsible for preparation, review of technical content, and initial or
revision approval
· Have a clear and organized report format and allow data to be extracted easily
· Ensure reports contain sufficient information to permit their repetition
· Require the appropriate test and evaluation procedures
· Ensure that technical corrections involve qualified personnel
3. Procedures for report distribution limit copies of the test report only to those who needs the
information.
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 19
Detailed Application Information/Evaluation Criteria
B. Complaints
1. A record is maintained of all complaints, appeals, and disputes received from clients, product users,
or other parties.
2. Complaints, appeals, and disputes are resolved following documented policies and procedures that
require documenting findings, remedial action, and effectiveness of solutions; and that provide
complainants with a fair and reasonable opportunity for input.
3. Appropriate action is taken to correct root causes of situations leading to the complaints.
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 20
Detailed Application Information/Evaluation Criteria
OPTIONAL INFORMATION
Provide information for the following two sections only if applicable to the application. Note:
roman numerals I and II of the following outline do not represent recognition requirements.
I. Supplemental Programs (see March 9, 1995 FR notice for more details)
For this section, address the criteria shown under “Use of Supplemental Programs” or under
each program, explaining how each criteria will be met.
(Note: Program 1 is the basic program under which all product testing and evaluation is performed inhouse by the NRTL that will certify the product. The evaluation to grant this program is
encompassed in the overall evaluation for the initial recognition of an NRTL)
A.Use of Supplemental Programs
To use a supplemental program, the applicant or NRTL
· Is recognized to perform the tests and evaluations before it can accept such services from other
organizations, except for unique or special testing needs.
· Uses assessors having qualifications consistent with the competence requirements of the
appropriate national standards and international guides to qualify organizations.
· Ensures that all aspects of certification work performed by others--including participants,
locations of testing, witnessing, and evaluations--are identified in the NRTL and client records
and reports.
OSHA auditor’s review & findings:
B. Programs 2 &3: Acceptance of Testing Data and Product Evaluation From Independent
Organizations, Other Than NRTLs
1. For acceptance of test data, the applicant or NRTL
· Ensures that the independent lab is capable of doing the tests and that its relationship with the
lab will not compromise the NRTL’s independence
· Retains control and responsibility for all aspects of the product certification scheme
· Reviews each test package and completes the product evaluation for the test standard
· Ensures that all test data originates with the test lab
· Assesses the test lab using a written qualification program, which includes assuring the lab is
accredited to ISO Guide 25 or its equivalent
· Has qualification procedures for evaluating the organization's independence, facilities, utilities,
environmental controls, personnel, testing and calibration equipment, written testing
procedures, calibration procedures, quality assurance program, and other elements as outlined in
ISO Guide 25 or its equivalent
· Uses a surveillance program, meeting the appropriate national standards and international
guides, to ensure continued qualification of organization.
2. For acceptance of product evaluations, the applicant or NRTL:
· Meets the criteria for Program 2
· Reviews each evaluation package and completes the required product evaluations before the
product certification is issued
· Ensures that the evaluations are from an outside organization which it has qualified
· Ensures that all data have been developed under the program established by the NRTL
· Requires the organization to maintain documentation of technical correspondence and test
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 21
Detailed Application Information/Evaluation Criteria
·
·
·
·
interpretations
Requires the organization to follow the written procedures established by the NRTL, in
preparing the evaluation package
Ensures that independence is maintained
Uses the NRTL's qualification program to qualify the organization relative to each product type
it may be asked to evaluate, and to assure the relationship between the NRTL and the
organization does not compromise the NRTL's independence
Has a minimum period and level of mutual effort for confidence-building as part of its
qualification program.
OSHA auditor’s review & findings:
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 22
Detailed Application Information/Evaluation Criteria
C. Program 4: Witnessed Testing
For acceptance of witness testing, the applicant or NRTL
· Retains control and responsibility for all aspects of the product certification plan
· Trains its staff to participate in the various phases of testing, including specific testing
procedures for appropriate product types they may witness
· Ensures that the organization is capable of conducting the tests
· Ensures that the relationship between the NRTL and the organization does not compromise the
NRTL’s independence
· Assesses the organization using a written qualification program, which includes assuring the lab
is accredited to appropriate section of ISO Guide 25 or its equivalent
· Has qualification procedures for evaluating the organization's facilities, utilities, environmental
controls, personnel, testing and calibration equipment, written testing procedures, calibration
procedures, quality assurance program, and other elements as outlined in ISO Guide 25 or its
equivalent
· Uses only its personnel to qualify organizations and for witness testing.
OSHA auditor’s review & findings:
D.Programs 5 & 6: Acceptance of Testing and Evaluation Data From Non-Independent Organizations
1. For acceptance of test data, the applicant or NRTL
· Meets the criteria for Program 2, except for the need to document the labs independence
· Establishes procedures and maintains records which will demonstrate that test data are unbiased
· Ensures that the organization providing the data is capable of conducting the tests
· Ensures that the relationship between the NRTL and the organization does not compromise the
NRTL's independence
· Establishes in its qualification procedures a minimum period for building confidence in the
organization
· Verify testing capability through witnessing tests at the organization and by replicating tests at
the NRTL's facility during the confidence-building period
· Performs as part of its surveillance program annual site evaluations, review of test packages,
and random sampling and retests.
2. For acceptance of evaluation data, the applicant or NRTL
· Meets the criteria for Programs 2, 3, and 5, excluding the need for independence
· Ensures that no product is released to the market until the NRTL has verified the organization’s
testing data and concurred with the evaluation
· Maintains records of any procedural or product deficiencies identified and the corresponding
corrective actions
· Maintains records that demonstrate that the organization continues to be proficient in testing
and evaluation
· Ensures that the relationship between the NRTL and the organization does not compromise the
NRTL's independence.
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 23
Detailed Application Information/Evaluation Criteria
OSHA auditor’s review & findings:
E. Program 7: Acceptance of Continued Certification after Minor Product Modification by the
Manufacturer
For acceptance of continued certification, the applicant or NRTL
· Meets the criteria for Programs 2, 3, 5 and 6
· Defines what specifically is meant by minor modifications
· Reviews each test and evaluation report for each product modification
· Ensures that each manufacturer providing test data and evaluation is capable of conducting the
tests and evaluations
· Ensures that the relationship between the NRTL and the manufacturer does not compromise the
NRTL's independence
· Maintains records that demonstrate that the organization continues to be proficient in testing
and evaluation.
OSHA auditor’s review & findings:
F. Program 8: Acceptance of Product Evaluations from Organizations That Function As Part of the
International Electrotechnical Commission Certification Body (IEC-CB) Scheme
For acceptance of product evaluations under the IEC-CB Scheme, the applicant or NRTL
· Retains control and responsibility for the product certification scheme
· Physically evaluates each product
· Reviews each test and evaluation report and certificate to determine that the correct nationally
recognized standards have been used and that any U.S. deviations have been applied
· Uses written procedures for evaluation and interpretation of results
· Establishes records that demonstrate the organizations’ continued competence and
understanding of the U.S. deviations and their applications
· Determines that components used are tested to a standard comparable to the appropriate
nationally recognized standard
· Determines that components used have been certified by an appropriate regulatory authority,
including routine evaluation of the manufacturer’s process.
OSHA auditor’s review & findings:
G.Program 9: Contract Services (Other Than Testing or Evaluation)
For acceptance of contract services, the applicant or NRTL
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 24
Detailed Application Information/Evaluation Criteria
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
Retains control and responsibility for all aspects of the product certification scheme
Ensures that those performing such services have been assessed and qualified by the NRTL
Ensures that subcontractors or agents use the NRTL’s follow-up procedures
Maintains records of the results of the follow-up visits
Ensures that subcontractors or agents are capable of performing the service and that the NRTL's
relationship with the subcontractor or agent does not compromise the NRTL's independence
Demonstrates that subcontractors or agents are capable of providing services equivalent to those
provided by the NRTL
Has written procedures to qualify subcontractors or agents, to monitor their performance, to
obtain proper reports and documentation of their activities, and to maintain manufacturers’
confidentiality
Assures subcontractors or agents maintain quality assurance or self-auditing programs and
appropriate documentation of these activities
Uses its staff to train subcontractor or agent staff
Ensures that only qualified follow-up inspectors conduct inspections
Provides a surveillance program for routine audits of facilities, staff and procedures
Ensures that follow-up in foreign countries is as stringent as that required in the U.S.
Ensures that the follow-up program includes assessment of manufacturer procedures, quality
control system, maintenance procedures, record keeping and other elements from appropriate
national standards and international guides
Ensures that the follow-up program has the capability to identify variations in the
manufacturer's ability to control quality of production
Inspects samples of products for compliance
OSHA auditor’s review & findings:
II. ANSI, A2LA, and NVLAP or other third party assessment data
The applicant or NRTL may submit assessment reports or data from third party auditors such as
ANSI, A2LA, or NVLAP. If any such reports are submitted, they must include documentation
showing the tracking and completion of corrective actions. In addition, to be accepted by OSHA:
A.The on-site review or data must be dated within two years of the date of the filing of the application
for NRTL recognition, and must be updated if there has been any significant changes in
procedures, key personnel, facilities or programs, since the date of the data or the report.
B. The entire report or data is submitted to OSHA with a signed letter that releases the report for use by
OSHA, and identifies any sections of the report that are not to be used.
C. The report is signed, dated, identifies the personnel that performed the review, and the dates of the
review.
Application Guidelines for the OSHA NRTL Program (as of 10/1/2000)
Page 25
File Type | application/pdf |
File Title | Microsoft Word - appllicationguide.doc |
File Modified | 2007-04-13 |
File Created | 2007-04-13 |