Extracted Text

OMB NO.: 0580-0013
(See reverse)

U.S. DEPARTMENT OF AGRICULTURE
GRAIN INSPECTION, PACKERS AND STOCKYARDS ADMINISTRATION
FEDERAL GRAIN INSPECTION SERVICE

SAMPLER CONDITION REPORT
NAME OF ELEVATOR, CITY, AND STATE

DATE EXAMINED

FIELD OFFICE

NAME OF OFFICIAL AGENCY

*INSTRUCTIONS TO EXAMINER: For a six month examination fill out the front of this form. For a complete grain test, including initial sampler test, fill out both
sides of this form and send the original to the FGIS Field Office. Explain "FAIL" items in detail. If the sampler is not being used, indicate that fact under
"Remarks" and prepare a report before the sampler is put into use.
PRIMARY SAMPLER

SECONDARY SAMPLERS

BRAND/MODEL

SERIAL NO.

BRAND/MODEL

SERIAL NO.

GRAIN FLOW RATE (Past Sampler)

SAMPLING INTERVAL (Cycle Time)

BRAND/MODEL

SERIAL NO.

SAMPLER
CODE:

D - Diverter

4 - OUT Inspections

P - Probe
5 - Cargolots

0 - All Grains
6 - Bargelots

1 - Small Grains

2 - Coarse Grains-not corn

7 - Hopper Carlots

SECTION 1 -- ALL SAMPLERS

ITEMS EXAMINED

8 - Carlots

9 - Trucklots

SECTION 2 -- D/T SAMPLERS

PASS

/

FAIL

ITEMS EXAMINED

Lighting around sampler

Pelican speed approx. 0.5 m/s

Safe access to areas

Pelican dust seals (interior)

Safe access to inside of devices

Pelican go-no-go gauge

Lockouts (safety switches)

Pelican cuts entire grain stream

Cleanliness of area

Condition of excess sample return leg or belt

Cleanliness of device

Timer set correctly

PASS

/

FAIL

PASS

/

FAIL

SECTION 3 -- TRUCK PROBES

Lubrication (if required)
Panel board indicator lights

ITEMS EXAMINED

Air or hydraulic pressure

Tip not bent/damaged

Delivery tube secure

Tip vacuum check with paper

Delivery tube air inlet secure

Hydraulic oil level OK

Collection box secure

Vacuum adjustments sealed

Collection box screen clean

Sample size

Sampler not modified or repaired

Collection box seal

Seals/padlocks in place

Delivery tube condition

Inspected By: (LI or ACG)

Vacuum pressure if known:

Reviewed By: (ACG)

3 - IN Inspections

Form FGIS-936 (5-03) Previous editions are obsolete . Expires January 2015

OMB NO.: 0580-0013
(S ee revers e)

U.S . DE P A R T M E NT OF A GR IC ULT UR E
GR A IN INS P E C T ION, P A C KE R S A ND S T OC KY A R DS A DM INIS T R A T ION
F E DE R A L GR A IN INS P E C T ION S E R V IC E

SAMPLER CONDITION REPORT
NA ME OF ELEV A TOR, CITY , A ND STA TE

DA TE EXA MINED

FIELD OFFICE

NA ME OF OFFICIA L A GENCY
*INSTRUCTIONS TO EXA MINER: For a six month examination f ill out the f ront of this f orm. For a complete grain test, including initial sampler test, f ill
out both sides of this f orm and send the original to the FGIS Field Of f ice. Explain "FA IL" items in detail. If the sampler is not being used, indicate that
f act under "Remarks" and prepare a report bef ore the sampler is put into use.
PRIM ARY SAM PLER

SECONDARY SAM PLERS

B R A ND/M ODE L

S E R IA L NO.

B R A ND/M ODE L

GR A IN F LOW R A T E ( Past S ampler)

S A M PLING INT E R V A L ( C ycle T ime)

B R A ND/M ODE L

S A M PLE R
C ODE :

D - Diverter

4 - OUT Inspections

P - Probe
5 - Cargolots

0 - All Grains

1 - Small Grains

6 - Bargelots

S E R IA L NO.

2 - Coarse Grains-not corn

7 - Hopper Carlots

SECTION 1 -- ALL SAM PLERS

ITEMS EXA MINED

S E R IA L NO.

8 - Carlots

SECTION 2 -- D/T SAM PLERS

PASS

/

FAIL

PASS

ITEMS EXA MINED

Lighting around sampler

Pelican speed approx. 0.5 m/s

Saf e access to areas

Pelican dust seals (interior)

Saf e access to inside of devices

Pelican go-no-go gauge

Lockouts (saf ety sw itches)

Pelican cuts entire grain stream

Cleanliness of area

Condition of excess sample return leg or belt

Cleanliness of device

Timer set correctly

Panel board indicator lights

ITEMS EXA MINED

A ir or hydraulic pressure

Tip not bent/damaged

Delivery tube secure

Tip vacuum check w ith paper

Delivery tube air inlet secure

Hydraulic oil level OK

Collection box secure

V acuum adjustments sealed

Collection box screen clean

Sample size

Sampler not modif ied or repaired

Collection box seal

Seals/padlocks in place

Delivery tube condition

Inspected By: (LI or A GC)

V acuum pressure if know n:

Form FGIS-936 (5-03) Previous editions are obsolete.

/

FAIL

SECTION 3 -- TRUCK PROBES

Lubrication (if required)

Review ed By: (A CG)

3 - IN Inspections
9 - Trucklots

PASS

/

FAIL

OMB NO.: 0580-0013
(S ee revers e)

E

initial sampler test, f ill
eing used, indicate that

S

3 - IN Inspections
9 - Trucklots

RS

PASS

/

FAIL

ES

PASS

/

FAIL

INSTRUCTIONS FOR COMPLETING
FORM FGIS-936, "SAMPLER CONDITION REPORT," (FRONT)
1. Name of the elevator, city, and state.
2. Date examination was done.
3. Name of FGIS field office in charge of the circuit.
4. Name of the official agency that does original inspections at the facility.
5. Brand name and type of primary (diverter-type sampler) or probe-type sampler being
examined and tested. Are they of a type approved by FGIS?
6. Serial number of primary diverter-type or probe-type sampler.
7. Brand name of secondary sampler.
8. Serial number of secondary sampler.
9. Calculate the maximum flow of spout or belt on which the sampler is installed.
10. Sampling Interval-Read from the timer.
11. Type of carriers or lots the system will sample.
Section 1 – All Samplers
12. Lighting should be approximately 30 footcandles (general task lighting).
13. Safe access includes approved stairs, fixed ladders, platforms, and railings.
14. Safe access to the inside of the housing or hood without endangering the examiner.
15. Lockout switches must be present and meet requirements.
16. Cleanliness of the area-overhead, floor, stairs.
17. Cleanliness/condition of primary-check for plugs, leaks, dust, sprouted grain, broken
hasps/hinges, wiring.
18. Lubrication-Grease or oil leaks.
19. Panel lights-Use radio or phone (if needed) to ensure that the power and traverse lights work
properly. Have any changes been made in the wiring?
20. Air or hydraulic pressure-Is there enough? Record the gage pressure, if available.
21. Delivery tube must be secure from loss or introduction of material.
22. Delivery tube-Pneumatic systems must have a guard over the air supply inlet.
23. Collection box-If not continuously attended, must be secure at inlet and outlet.
24. Collection boxes that have a screen must be maintained in a clean condition.
25. Sampler not Modified-For this check, good installation records are essential.
26. Seals-Were the security seals on inspection doors found intact? Was the delivery tube found
secure?
Section 2 – D/T Samplers
27. Pelican speed must be uniform with no slow spots. Speed can be estimated.
28. Pelican dust seals-Must be present, not torn, and must seal-off the pelican, no air gap.
29. Pelican Go-no-go Gauge-Use it to ensure the opening is between 3/4 and 7/8 inch wide
along its entire length.
3 The reverse of Form FGIS-936 is used for performing a test (grain test). Instructions for completin
are contained in Chapter 5, Tests.
30. Pelican cuts stream-If practical, observe a cut to see that the pelican is sampling the entire
stream, and that it does not back up from excess grain.
31. Condition of excess sample return-Check if it is leaking, infested, or backing up.
32. Timer-Does the timer setting match the documented setting (required). Use a stopwatch or
read the timer; do not rely on posted signs or old records.
Section 3 – Truck Probes
33. Probe tip must be in good condition.
34. For core-type probes, a small piece of paper is placed over the tip to check the air
supply/vacuum balance. The paper should not fall off or be sucked into the tip.
35. Check levels if possible.
36. After adjustment, air supply/vacuum balance should not be changed. If it is possible to seal
them or record settings, this provides assurance that they remain correctly adjusted.

37. Is the sample size adequate? Has it changed?
38. If the collection box has a gasket, is it in good condition with no air leaks.
39. Is the delivery tube in good condition,
40. If a gage reading is available, it can indicate leaks or misadjustment.
Name of Inspector
41. Show the name of the inspector who completed the examination. If any item is
unsatisfactory, the sampler is not acceptable. Keep the not acceptable Form FGIS-936 as a
record. Even if the facility brings the sampler into compliance immediately, complete
another form.
42. An ACG should review some forms for correctness when possible. Any questionable
information or remarks must be verified to be accurate.

e-type sampler being

er is installed.

and railings.
gering the examiner.

prouted grain, broken

power and traverse lights work

essure, if available.

air supply inlet.
nlet and outlet.
ean condition.
are essential.
? Was the delivery tube found

be estimated.
the pelican, no air gap.
en 3/4 and 7/8 inch wide

n test). Instructions for completing the reverse

elican is sampling the entire

d, or backing up.
quired). Use a stopwatch or

tip to check the air

nged. If it is possible to seal
orrectly adjusted.

n. If any item is
able Form FGIS-936 as a
ediately, complete

ble. Any questionable

According to the Paperwork Reduction Act of 1995, an agency may not conduct or sponsor, and a person is not required to respond to a collection of information unless it displays a valid OMB control number. The
valid OMB control number for this information collection is 0580-0013. The time required to complete this information collection is estimated to average 45 minutes per response, including the time for reviewing
instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information.

GRAIN TEST DATA
SAMPLING METHOD USED FOR STANDARD:
CUP
PELICAN
COMMODITY:
SMALL GRAIN

COARSE GRAIN

for Mechanical Truck Probes only

OTHER

Date

OTHER

Sample No.

6

REMARKS:

7

8

9

10

11

12
Date

Sample No.

Type

1

Test Unit
Standard

DKG

BCFM

13

Difference
Tolerance

14

Result - One test lot

Date

Sample No.

Type

2

Test Unit
Standard

3

Test Unit
Standard

4

Test Unit
Standard

5

Test Unit
Standard

IN

IN

IN

OUT

OUT

OUT

DKG

BCFM

15

16

17

18

19

20
Test Unit MDS*
Tolerance
Result - Five test lots

IN

IN

IN

OUT

OUT

OUT

*Mean Deviation from Standard
Form FGIS-936 (5-03) Previous editions are obsolete .

Type

DKG

BCFM

IN

IN

IN

OUT

OUT

OUT

Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP
Test Unit
Standard
HP

Test Unit MDS*
Hand Probe MDS*
Regression or T-test

INSTRUCTIONS FOR COMPLETING
FORM FGIS-936, "SAMPLER CONDITION REPORT,"
(REVERSE)
Use the reverse of Form FGIS-936 for testing (grain test). Always precede a test with an
examination, documented on the front of the form. If the examination and the test are not
recorded on the same sheet, properly identify the test by filling in the Name of Elevator, etc.,
Items 1 through 11, 41 and 42 on the front as described in Chapter 4, Examinations.
1. Method of sampling-What was the standard? If a special location or procedure was used,
explain in remarks.
2. Specify grain.
3. Remarks-Summary of important observations on the sampling system and testing
information. Was the test run at normal load-out speed, air pressure, belt depth, etc.? Was
dust collection turned on? Shipping bins checked?
4. Enter date sampled.
5. One factor is required, but additional factors may be tested. If necessary, the field office
manager shall decide the appropriate factors. Test weight is not to be used as the only factor.
Report percentages to 2 decimal places.
6. Mathematical average of the mechanical sampler results, average of the standard results,
average of other results. Round percentages to 2 places.
7. Tolerance or allowable deviation = 0.10 x (standard average).
8. Mark the appropriate box for each factor tested. If more than one factor was tested, each of
them must be within tolerance for a pass. A factor is considered within tolerance when the
mean deviation from the standard is less than or equal to the allowable deviation for the
applicable factor(s).
9. If 5 test lots are to be evaluated, continue entering sample data.
10. If testing a mechanical truck probe, continue entering sample data for 20 test lots.
11. Truck probe performance is evaluated against a standard and a hand probe, using either a
regression or a T-test. Technical Service Division provides support for the analysis.

precede a test with an
on and the test are not
he Name of Elevator, etc.,
4, Examinations.
n or procedure was used,

ystem and testing
e, belt depth, etc.? Was

ecessary, the field office
be used as the only factor.

ge of the standard results,

e factor was tested, each of
thin tolerance when the
able deviation for the

ata for 20 test lots.
a hand probe, using either a
for the analysis.