Download:
pdf |
pdfContains Nonbinding Recommendations
eCopy Program for Medical Device
Submissions
Guidance for Industry and Food
and Drug Administration Staff
Document issued on December 3, 2015.
This document supersedes the guidance of the same title dated
October 10, 2013.
For questions regarding this document, contact CDRH’s eCopy Program Coordinators at 240402-3717 or [email protected] or CBER’s Office of Communication, Outreach and
Development, at 1-800-835-4709 or 240-402-8010.
U.S. Department of Health and Human Services
Food and Drug Administration
Center for Devices and Radiological Health
Center for Biologics Evaluation and Research
Contains Nonbinding Recommendations
Preface
Public Comment
You may submit electronic comments and suggestions at any time for Agency consideration to
http://www.regulations.gov. Submit written comments to the Division of Dockets Management,
Food and Drug Administration, 5630 Fishers Lane, Room 1061, (HFA-305), Rockville, MD, 20852.
When submitting comments, please refer to the exact title of this guidance document. Comments
may not be acted upon by the Agency until the document is next revised or updated.
Additional Copies
Additional copies are available from the Internet. You may also send an e-mail request to [email protected] to receive an electronic copy of the guidance. Please use the document
number (1797) to identify the guidance you are requesting.
Additional copies of this guidance document are also available from the Center for Biologics
Evaluation and Research (CBER), Office of Communication, Outreach, and Development (OCOD),
10903 New Hampshire Ave., Bldg. 71, Room 3128, Silver Spring, MD 20993-0002, or by calling
1-800-835-4709 or 240-402-8010, by emailing [email protected], or from the Internet at
http://www.fda.gov/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/default.h
tm.
Table of Contents
1. Introduction ................................................................................................................................................. 1
2. What is an eCopy? ....................................................................................................................................... 3
3. Are differences between the contents of an eCopy and paper submission acceptable? .............................. 3
4. For what submission types is an eCopy required?....................................................................................... 4
5. Are there other submission types not subject to the eCopy legislation for which eCopies may be
submitted? .................................................................................................................................................... 5
6. How many copies of a submission are needed? .......................................................................................... 6
7. What are the processing steps for an eCopy? .............................................................................................. 7
a.
b.
What are the technical standards for an eCopy? ............................................................................... 7
What are the recommended methods for creating an eCopy? ........................................................... 7
A. Bookmarks and Hyperlinks within PDFs ...................................................................................... 7
B. Creating a PDF File from the Source Document (Preferred)....................................................... 8
C. Creating a PDF File from a Scanned Document .......................................................................... 9
c. Are there special considerations when developing an eCopy for an original submission versus a
response to a review hold notification? ........................................................................................... 10
d. Are there any issues to consider when choosing the eCopy media? ............................................... 10
e. What if there is another submitting party involved? ....................................................................... 10
f. What if this is a Third Party 510(k)? ............................................................................................... 10
g. What if this is a bundled submission? ............................................................................................. 11
h. How do you create an eCopy that meets the technical standards? .................................................. 11
i. How do you know if an eCopy meets the technical standards before you send it to FDA?........ ... 12
j. How do you submit an eCopy to FDA? .......................................................................................... 13
k. How does FDA process an eCopy? ................................................................................................. 14
l. What do you provide to FDA in response to an eCopy hold?......................................................... 14
m. How does FDA process a replacement eCopy? .............................................................................. 15
n. What timeframes need to be considered? ........................................................................................ 15
o. When does review of a submission begin? ..................................................................................... 15
p. If you submitted an eCopy for a submission type that did not require an eCopy and you received
an eCopy hold letter, what are your options? .................................................................................. 15
8. What if your device is regulated by CBER? .............................................................................................. 16
a.
b.
c.
Will the new eCopy requirements apply? ....................................................................................... 16
Can you submit an electronic submission instead of an eCopy? .................................................... 16
How do you prepare and submit an electronic submission to CBER? ............................................ 16
Attachment 1 – Technical Standards for eCopies ............................................................................................ 18
A.
B.
C.
D.
Company Cover Letter Requirements ............................................................................................. 19
Volume or Non-Volume Structure Requirements ........................................................................... 20
PDF File Requirements ................................................................................................................... 25
Requirements for How to Add Non-PDF Files via “STATISTICAL DATA” and “MISC FILES”
Folders ............................................................................................................................................. 28
eCopy Program for Medical Device
Submissions
Guidance for Industry and Food and
Drug Administration Staff
This guidance represents the current thinking of the Food and Drug Administration (FDA or
Agency) on this topic. It does not establish any rights for any person and is not binding on
FDA or the public. You can use an alternative approach if it satisfies the requirements of the
applicable statutes and regulations. To discuss an alternative approach, contact the FDA staff
or Office responsible for this guidance as listed on the title page.
1. Introduction
This is an updated version of the guidance that was issued on October 10, 2013. It provides
clarification to the processing and technical standards for eCopies based on FDA’s experience to
date with the program.
The purpose of this guidance is to explain the new electronic copy (eCopy) Program for medical
device submissions. Section 745A(b) of the Federal Food, Drug, and Cosmetic Act (FD&C
Act), added by section 1136 of the Food and Drug Administration Safety and Innovation Act
(FDASIA) (Pub. L. 112-144), requires the submission of eCopies with the issuance of this final
guidance. This guidance describes how the Food and Drug Administration (FDA) is
implementing the eCopy Program under section 745A(b) of the FD&C Act. The inclusion of an
eCopy is expected to improve the efficiency of the review process by allowing for the immediate
availability of an electronic version for review rather than relying solely on the paper version.
This guidance provides, among other things, the standards for a valid eCopy under section
745A(b)(2)(A) of the FD&C Act. In accordance with section 745A(b), submission types
identified in this final guidance must include an eCopy in accordance with the standards
provided by this guidance for the submission to be processed and accepted for review by FDA,
unless they have been identified as being exempted or waived. Submissions submitted without
an eCopy and eCopy submissions that do not meet the standards provided in this guidance will
be placed on hold until a valid eCopy is submitted to FDA and verified to meet the standards,
unless a waiver or exemption has been granted. While the submission is on hold, the review
clock will not begin and the submission will not be reviewed.
In section 745A(b), Congress granted explicit statutory authorization to FDA to implement the
statutory eCopy requirement by providing standards, criteria for waivers, and exemptions in
guidance. Accordingly, to the extent that this document provides such requirements under
section 745A(b) of the FD&C Act (i.e., standards, criteria for waivers, and exemptions),
1
indicated by the use of the words must or required, this document is not subject to the usual
restrictions in FDA’s good guidance practice (GGP) regulations, such as the requirement that
guidances not establish legally enforceable responsibilities. See 21 CFR 10.115(d).
However, this document also provides guidance on FDA’s interpretation of the statutory eCopy
requirement and the Agency’s current thinking on the best means for implementing other aspects
of the eCopy program. Therefore, to the extent that this document includes provisions that are
not “standards,” “criteria for waivers,” or “exemptions” under section 745A(b)(2), this document
does not create or confer any rights for or on any person and does not operate to bind FDA or the
public, but does represent the Agency’s current thinking on this topic. The use of the word
should in such parts of this guidance means that something is suggested or recommended, but
not required. You can use an alternative approach if the approach satisfies the requirements of
the applicable statutes and regulations. If you want to discuss an alternative approach, contact
the FDA staff listed on the title page of this guidance.
To comply with the GGP regulations and make sure that regulated entities and the public
understand that guidance documents are nonbinding, FDA guidances ordinarily contain standard
language explaining that guidances should be viewed only as recommendations unless specific
regulatory or statutory requirements are cited. FDA is not including this standard language in
this guidance because it is not an accurate description of all of the effects of this guidance. This
guidance contains both binding and nonbinding provisions. Insofar as this guidance provides
“standards,” “criteria for waivers,” and “exemptions” pursuant to section 745A(b) of the FD&C
Act, it will have binding effect.
The eCopy program is not intended to impact (reduce or increase) the type or amount of data the
applicant 1 includes in a submission to support clearance or approval. Please refer to other FDA
device or program-specific guidance documents from CDRH
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/defau
lt.htm) and CBER
http://www.fda.gov/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/Guida
nces/General/ucm214106.htm) for the appropriate contents for submissions.
For additional eCopy Program resources, please refer to FDA’s webpage entitled, eCopy
Program for Medical Device Submissions
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/HowtoMarketYourDevice/
UCM370879.htm).
1
For the purposes of this guidance, applicant includes “submitter,” “sponsor,” or “holder.”
2
2. What is an eCopy?
An electronic copy (eCopy) is defined as an exact duplicate of the paper submission, created and
submitted on a compact disc (CD), digital video disc (DVD), or a flash drive. An eCopy is
accompanied by a paper copy of the signed 2 cover letter and the complete paper submission. 3
3. Are differences between the contents of an eCopy and
paper submission acceptable?
While an eCopy is defined as an exact duplicate of the paper copy, there are limited cases in
which differences between the eCopy and the paper copy may be justified because a paper copy
is not practical or appropriate for analysis purposes (e.g., raw data and statistical analysis
programs, 4 data line listings to facilitate a bioresearch monitoring review) or is not feasible (e.g.,
videos, x-rays). The critical attribute of an eCopy is that it must include in electronic form all
data required for that submission type. 5 In other words, the eCopy must include all of the
required information for FDA review, whereas the paper copy can include a placeholder crossreferencing the location of certain information in the eCopy.
The cover letter must contain the modified eCopy statement described in Attachment 1 and
describe any differences between the paper version and the eCopy. If information is included in
the eCopy that is not in the paper copy, then the paper copy must have a placeholder to redirect
the reviewer (e.g., a piece of paper with a statement directing the reviewer to a particular section
in the eCopy).
FDA will consider the eCopy, with the cover letter, loaded into the appropriate Center’s official
document repository to be the official record. Any undisclosed differences between the eCopy
and the paper version may need to be rectified and could delay the review of the submission.
2
The cover letter signature may be a wet (i.e., ink) signature or a valid digital signature. Please note that other
forms submitted within an IDE or premarket submission (e.g., Truthful and Accurate Statement for 510(k)s) can
also be signed with either a wet signature or digital signature.
3
An eCopy is not considered to be an electronic submission. For information on eSubmissions, refer to “FDA
eSubmitter” (http://www.fda.gov/ForIndustry/FDAeSubmitter/default.htm) and “Regulatory Submissions in
Electronic Format for Biologic Products”
(http://www.fda.gov/BiologicsBloodVaccines/DevelopmentApprovalProcess/ucm163685.htm).
4
For information on electronically submitted data, refer to “Clinical Data for Premarket Submissions”
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/HowtoMarketYourDevice/PremarketSubmissi
ons/ucm136377.htm).
5
For example, the content requirements for a 510(k) submission are found in 21 CFR 870.87 and 807.92; those for
original PMA submissions are found in 21 CFR 814.20.
3
4. For what submission types is an eCopy required?
In accordance with Section 745A(b) of the FD&C Act, as added by section 1136 of FDASIA,
and the CDRH guidance on Q-submissions 6, an eCopy is required for the following submission
types:
•
•
•
•
•
•
•
•
•
•
•
Premarket notification submissions (510(k)s), including third party 510(k)s;
Evaluation of automatic class III designation petitions (de novos);
Premarket approval applications (PMAs), including Transitional PMAs; 7
Modular PMAs;
Product development protocols (PDPs);
Investigational device exemptions (IDEs) [see partial Exemptions below];
Humanitarian device exemptions (HDEs) 8
Emergency Use Authorizations (EUAs) 9 [see Exemptions below];
Certain investigational new drug applications (INDs); 10
Certain biologics license applications (BLAs); 11
Q-submissions;6 and
eCopies for all subsequent submissions to an original submission, including amendments
(amendments include add-to-files, CLIA categorization add-to-files, and appeals), supplements,
and reports (reports include annual/periodic and post-approval reports) 12 to the submission types
identified above would also be required. Whether it is a single-page submission (i.e., the
company cover letter is the only content) or a multi-volume submission, the eCopy requirements
apply. Although there is no maximum total submission size restriction, it is recommended that
the total package submission not exceed 1 GB to avoid possible load time failures that may delay
the submission process.
6
“Requests for Feedback on Medical Device Submissions: The Pre-Submission Program and Meetings with Food
and Drug Administration Staff” (http://www.fda.gov/ucm/groups/fdagov-public/@fdagov-meddevgen/documents/document/ucm311176.pdf).
7
This includes all PMA submission types, including, but not limited to, original PMAs, panel-track supplements,
180-day supplements, manufacturing site change supplements, 30-Day Notices, 135-Day Supplements, and postapproval study supplements and reports, as well as amendments involving changes in the correspondent or
ownership and requests for extensions.
8
This includes all HDE submission types, including, but not limited to, original HDEs, 180-day supplements,
manufacturing site change supplements, 30-Day Notices, 135-Day Supplements, and post-approval study
supplements and reports, as well as amendments involving changes in the correspondent or ownership and requests
for extensions.
9
Refer to the guidance entitled, “Emergency Use Authorization of Medical Products”
(http://www.fda.gov/RegulatoryInformation/Guidances/ucm125127.htm) for more information on EUAs.
10
Applicable only to those devices that are regulated by CBER as biological products under Section 351 of the
Public Health Service (PHS) Act and that also require submission of an IND prior to submission of a BLA. Such
devices are generally those intended for use in screening donated blood for transfusion transmissible diseases.
11
Applicable only to those devices that are regulated by CBER as biological products under Section 351 of the PHS
Act, including those that do not require submission of an IND prior to the submission of the BLA. Such devices
generally include those reagents used in determining donor/recipient compatibility in transfusion medicine.
12
Section 745A(b) of the FD&C Act does not apply to Medical Device Reports submitted under 21 CFR Part 803.
4
Responses to deficiency letters are required to be formally submitted to CDRH’s or CBER’s
Document Control Center 13 (DCC) to be logged in as an amendment or a supplement and, thus,
are subject to the eCopy requirements.
Please note that eCopy requirements do not apply to information obtained during the
Interactive Review process (via email, phone, and/or fax) once a submission is under
review, if that information is not mailed to FDA. However, should an applicant choose to
mail a response to an Interactive Review request (which should only occur if the size of the
response makes communication by email or fax infeasible), it will be logged in as an amendment
and be subject to the eCopy requirements.
Exemptions
Above, FDA identified the submission types cited in the legislation as being subject to the eCopy
requirements. However, the legislation also allows for FDA to set forth criteria for exemptions
from eCopy requirements. Accordingly, due to the potentially urgent nature of the following
types of submissions, FDA considers these to be exempt from the requirement for an eCopy:
•
three specific types of IDEs - compassionate use IDE submissions, emergency use IDE
submissions 14, and adverse event reports; and
•
all EUAs.
Although these submission types do not require eCopies as per this exemption, FDA encourages
you to submit eCopies of these submissions, when feasible, in order to facilitate the review
process. 15 If you choose to submit an eCopy, it must meet the technical standards outlined in
Attachment 1.
Waivers
FDA believes that, given the widespread availability of software to enable the creation of an
acceptable eCopy at little to no cost, all applicants should have the ability to provide an eCopy.
5. Are there other submission types not subject to the eCopy
legislation for which eCopies may be submitted?
Although an eCopy is not required under Section 745A(b) of the FD&C Act, FDA also accepts
and encourages you to submit eCopies for:
13
Refer to 21 CFR 807.90 for the DCC addresses for CDRH and CBER.
Please refer to CDRH’s device advice page entitled “IDE Early/Expanded Access”
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/HowtoMarketYourDevice/InvestigationalDevi
ceExemptionIDE/ucm051345.htm#compassionateuse) and FDA’s “Guidance on IDE Policies and Procedures”
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm080202.htm) for
additional details on compassionate and emergency use IDE submissions.
15
If submission of an eCopy is not feasible, but there is pertinent electronic information, such as imaging data, to
supplement the information in the paper copy, please contact the lead reviewer to submit this information via
Interactive Review.
14
5
•
Master Access Files (MAFs);
•
513(g) Requests for Information (513(g)s); and
•
Clinical Laboratory Improvement Act (CLIA) Categorization – Exempt Device
submissions (CLIA “X” files).
eCopies for these three submission types are voluntary; however, if you choose to submit an
eCopy, it must meet the technical standards outlined in Attachment 1.
6. How many copies of a submission are needed?
The eCopy Program does not change the overall number of copies to submit to FDA. Table 1
below provides the number of copies associated with each submission type for which an eCopy
is either required or voluntary.
Table 1 – Number of Copies for Submission
Submission Type
510(k)s
Third Party 510(k)s
De Novos
PMAs, including Transitional PMAs
• Original PMAs
• Panel-Track Supplements
• All other PMA supplement types (e.g., 180-Day
Supplements, Real-Time Supplements, 30-Day
Notices, 135-Day Supplements)
• PMA reports (annual reports and post-approval
study reports)
PDPs
Required or
Voluntary
eCopy
Required
Required
Required
Total Number of
Copies
Required
Required
Required
6 17
617
3 18
Required
2
Required
2 16
216
2
HDEs
Required
Modular PMAs
IDEs
• Compassionate use IDEs
• Emergency use IDEs
• Adverse Event Reports
Required
See PMAs for
corresponding type
See PMAs for
corresponding type 19
3
Voluntary
Voluntary
Voluntary
3 20
320
320
16
See 21 CFR 807.90(a)(3)(c).
See 21 CFR 814.20(b)(2).
18
See 21 CFR 814.39(c).
19
See 21 CFR 814.104(b)(4).
20
See 21 CFR 812.20(a)(3).
17
6
Submission Type
• All other types of IDE submissions
EUAs
Q-Submissions
MAFs
513(g)s
CLIA X Files
INDs
BLAs
For submission types for which eCopy requirements apply:
Required or
Voluntary
eCopy
Required
Voluntary
Required
Voluntary
Voluntary
Voluntary
Required
Required
Total Number of
Copies
320
2
2
2
2
2
3 21
3
•
If a total of two copies are required, you must submit one full paper copy and one eCopy
(with a cover letter with a signature and an adequate eCopy statement).
•
If more than two copies are required, then you must submit one full paper copy and all
remaining copies as eCopies (with a single cover letter with a signature and an adequate
eCopy statement). For example, for an original PMA, you must submit one paper copy
and five eCopies. 22
On the other hand, for compassionate use IDE submissions, emergency use IDE submissions,
EUAs, MAFs, 513(g)s, and CLIA X files, you may choose to submit only paper copies because
an eCopy is voluntary. However, if you choose to submit an eCopy for one of these submission
types, it must meet the technical standards outlined in Attachment 1.
7. What are the processing steps for an eCopy?
Below are the processing steps for the submission and acceptance of an eCopy.
a. What are the technical standards for an eCopy?
The technical standards for an eCopy are detailed in Attachment 1. An eCopy that does not
meet the technical standards in Attachment 1 will not be accepted.
b. What are the recommended methods for creating an eCopy?
A.
Bookmarks and Hyperlinks within PDFs
Bookmarks and hyperlinks within a single PDF file should be used to assist the reviewers in
navigating through the content of the submission. However, while these are not required
elements for an eCopy, bookmarks and hyperlinks are essential for the efficient navigation
through documents. If you use either bookmarks or hyperlinks, consider the following:
21
22
See 21 CFR 312.23(d).
FDA review staff should not request an additional eCopy or paper copy of a submission from the applicant.
7
Bookmarks and links references can be created for the heading of a section, subsection, or
title of figures and tables within a single PDF file. In general, including a meaningful
bookmark to the main table of contents for a submission or item is helpful, and will aid the
reviewer in locating information and navigating the submission.
Hyperlinks are used to improve navigation through individual PDF documents and are
encouraged. Hyperlinks can be designated by rectangles using thin lines or by blue text or
you can use invisible rectangles for hypertext links in a table of contents to avoid obscuring
text. 23 Hyperlinks throughout the body of the document to support annotations, related
sections, references, appendices, tables, or figures that are not located on the same page are
helpful and improve navigation efficiency.
Bookmarks and links are usually most easily created in a word processor by using titles,
headers, or styles which can be translated to bookmarks when the file is converted to PDF.
Alternatively, bookmarks can be created in the final PDF document either by selecting text
and creating a new bookmark to that location with that text as the name, or making a new
bookmark and naming it manually.
While it is common to use bookmarks and hyperlinks within a single PDF file, it is also
possible to create bookmarks and hyperlinks to other PDF files in your submission. We
recommend using bookmarks and hyperlinks to other PDF files when use of those features
will assist reviewers navigating through your submission. If you choose to use these features
to navigate between different PDF files, then please remember to 1) use relative rather than
absolute file paths, 2) use file names that are consistent with the eCopy requirements, and 3)
use folder names that are consistent with the eCopy requirements. Please note the
requirement to use of numeric prefixes in file names, which will allow your files to appear in
a meaningful order (rather than alphabetical order based on the first letter of each file name).
Changing the file or folder names after you insert the links will break the links. If you use
the eSubmitter tool to modify your file or folder names in order to fulfill the eCopy
requirements, then any links between PDF files may no longer function.
B.
Creating a PDF File from the Source Document (Preferred)
Creating a PDF file from the source document is the preferred method of PDF creation,
because this will allow for the automatic creation of searchable text in the PDF. If you have
created hyperlinks and bookmarks in your document, we recommend that you test the links
after you have created the PDF file to ensure that the links function correctly. When creating
a PDF from the source document (e.g., Microsoft Word document), please consider the
following:
23
Note that use of blue text for hyperlinks is the most widely recognized style.
8
1. Adobe Plug-Ins
If you use Adobe plug-ins within PDF files and/or to capture or display data, there is a risk
that information may not display correctly because reviewers may not have access to certain
plug-ins to review content being displayed by a plug-in.
2. Fonts
One of the following fonts should be used in your source document: Times New Roman;
Verdana; Arial; Tahoma; or Helvetica. You should avoid using customized fonts and
multiple fonts within the same document. We recommend the same font is used throughout
the submission.
We recommend the use of a black font color. Blue font may be used for hypertext links. If a
font color other than black is used, avoid light colors that do not print well on grayscale
printers. It is advised that you test the color reproduction prior to submission by printing
sample pages from the document using a grayscale printer. In addition to font colors, keep
formatting simple in tables.
We recommend a font size of 12; however, we will accept smaller fonts.
C.
Creating a PDF File from a Scanned Document
The applicant should create all PDF files directly from the source documents whenever
feasible rather than creating them by scanning. PDF documents produced by scanning
paper documents are far inferior to those produced directly from the source document,
such as a Microsoft Word document, and, thus, should be avoided if at all possible.
Paper documents that include a watermark, such as DRAFT or COPY, are not suitable for
scanning as the watermark makes the scanned document difficult or impossible to read.
Scanned documents, particularly tables and graphs, are more difficult to read and do not
allow the reviewers to copy and paste text for editing.
For any scanned document, we recommend that you perform optical character recognition
(OCR) so that the text is searchable. Check to see that the content has been correctly
converted by: (1) highlighting an area of text and (2) searching for a word or phrase. If the
word or phrase is not returned in the search, then the OCR did not recognize the text. FDA
recognizes that use of OCR may not be feasible in some cases for documents with figures
and images.
Scanned documents, particularly those with images, photographs, and video recordings tend
to be large in file size. Large file sizes may encounter more issues throughout the
submission process thus causing delays. Therefore, it is recommended that the total
submission package not exceed 1 GB.
Please note that FDA recognizes there may be cases in which it is appropriate to have
scanned documents added to an eCopy. For example, if you do not digitally sign the
Truthful & Accuracy Statement for a 510(k), then a scanned PDF copy of that signed
document would be added to the eCopy.
9
FDA recommends that you follow these methods to create an eCopy. However, while the
methods described in this section are not requirements for eCopy, your eCopy must meet the
technical standards in Attachment 1.
c. Are there special considerations when developing an eCopy for an original
submission versus a response to a review hold notification?
There are no special considerations because the eCopy program does not dictate the content
of a document (original, supplement, amendment, or report). Each eCopy is its own entity,
and the same technical standards in Attachment 1 apply to each eCopy. This means that
volume (if applicable) and PDF numbering start over with each new eCopy rather than
continuing from a previously-submitted eCopy. Do not provide previously-submitted
information in a cumulative fashion. Only include content pertinent to the current
submission (e.g., an eCopy for a response to a 510(k) hold notification only includes the
response content, not the original 510(k) content plus the response content). FDA
recommends that you first determine what your content is, and then provide an eCopy that
matches both in content and flow and meets the technical standards in Attachment 1.
d. Are there any issues to consider when choosing the eCopy media?
It is up to each applicant whether to burn your eCopy onto a CD, DVD, or flash drive.
However, please be aware that certain brands of media, particularly flash drives, come preloaded with files that may lead to your eCopy failing the loading process. You should check
the media for pre-loaded files and delete them before you burn your eCopy to the media.
e. What if there is another submitting party involved?
In the case that another party (e.g., law firm, consultant) submits a submission on behalf of
an applicant, the eCopy must still meet the technical standards in Attachment 1 in order to be
successfully processed by FDA. The eCopy requirements are the same regardless of who is
submitting the eCopy. While the applicant may or may not include their own company cover
letter as part of the eCopy, our technical standards require that the submitting party include a
company cover letter (with an eCopy statement and signature), as described in Section A of
Attachment 1.
f. What if this is a Third Party 510(k)?
There are two distinct parties involved in the generation of a Third Party 510(k): (1) the
Accredited Person and (2) the applicant. Each party is subject to the eCopy requirements.
Accordingly, each party (i.e., the Accredited Person and the applicant) must provide their
own:
• eCopy (on a single CD, DVD, or flash drive) that meets the standards in Attachment
1; and
• company cover letter with an eCopy statement and signature as described in Section
A of Attachment 1.
10
Therefore, there will be two separate eCopies provided for a given Third Party 510(k).
Given this, it is essential that each eCopy be clearly marked as belonging to the Accredited
Person or the applicant.
FDA recognizes that an applicant may interact with the Accredited Person multiple times
prior to the Third Party 510(k) being submitted to FDA. Regardless of the number of
interactions prior to the Third Party 510(k) being submitted to FDA, the applicant’s eCopy
must be on a single CD, DVD, or flash drive in order to be loaded by our software. This
could be accomplished by, for example, organizing each round of interaction as different
volumes in the eCopy (e.g., VOL_001_Original Review, VOL_002_Round 2 Review). The
Accredited Person must also provide their eCopy on a single CD, DVD, or flash drive for the
same reason.
Although the Accredited Person is FDA’s point-of-contact and is the party that will be sent
the eCopy hold notification if there are any issues with either eCopy, each party is
responsible for meeting the eCopy requirements.
g. What if this is a bundled submission?
For bundled submissions, there should be only one version of the company cover letter (with
an eCopy statement and signature) and only one eCopy that apply to all submissions in the
bundle. There should not be different company cover letters or eCopies associated with each
submission in the bundle. The company cover letter should include a list or table of all
submissions that are part of the bundle. The list or table should specify the submission
number, trade name, and, as applicable, the model number, of each device impacted by the
change.
h. How do you create an eCopy that meets the technical standards?
There is a free eSubmitter-eCopies tool available on FDA’s website at
http://www.fda.gov/ForIndustry/FDAeSubmitter/ucm317334.htm, which we encourage
applicants to use regardless of the Center to which you will be sending your submission. Use
of this tool is optional; however, one of the benefits of the tool is that it creates an eCopy in
real-time that is consistent with the technical standards described in Attachment 1. The tool
guides you through the steps of adding the content and will add any required prefixes to
volumes/folders and PDFs.
As an additional resource, there is a quick reference guide specific to the eSubmitter-eCopies
tool available at
http://www.fda.gov/downloads/ForIndustry/FDAeSubmitter/UCM319824.pdf. It is
important that you use only this reference guide when using the eSubmitter-eCopies tool and
not the generic eSubmitter guides that are available.
11
Tip to Sponsors: If you add any files to your eCopy after using the eSubmitter-eCopies tool, you may
create hidden temporary files or other errors that will cause the eCopy to fail the loading process. If a
document is open while you are adding it to the submission package and you have modified the
document without saving it, then both the document and the hidden cache file of the document will be
added to the submission package resulting in a failure when it reaches the FDA for processing. To
avoid this from occurring, you must save and close all documents prior to adding the document to the
submission package. Use the eCopy Validation Module described in Section 7i below, in order to verify
the format of the eCopy.
Please note that the eSubmitter-eCopies tool does not transmit the eCopy through the FDA
Gateway. Instead, as shown in Figure 1, the eSubmitter-eCopies tool provides the formatted
eCopy content for you to download onto your local computer drive and then burn onto a CD,
DVD, or flash drive. The eCopy content is saved in a folder with a long alpha-numeric
name. You need to open up the folder with the long alpha-numeric name that was saved on
your local computer drive and burn those contents onto your CD, DVD, or flash drive. Do
not add any of the files that the eSubmitter-eCopies tool saves on your local computer drive
outside of that folder with the long alpha-numeric name, as those additional files created by
the eSubmitter-eCopies tool are for your records only.
Figure 1: Snapshot of final packaging screen from eSubmitter-eCopies tool
Should you have any technical questions regarding the eSubmitter-eCopies tool, please
contact [email protected] prior to submission of the eCopy to FDA.
i. How do you know if an eCopy meets the technical standards before you
send it to FDA?
In order to determine if an eCopy meets the technical standards described in Attachment 1
before sending it to FDA, we recommend that applicants verify an eCopy using the free
eCopy Validation Module that is now on FDA’s website at
http://www.fda.gov/medicaldevices/deviceregulationandguidance/howtomarketyourdevice/u
12
cm370879.htm, which we encourage applicants to use regardless of the Center to which you
will be sending your submission. This voluntary tool will verify the format of an eCopy and
provide information on the error(s) contained in an eCopy.
Figure 2 below shows the initial screen of this tool. You first identify the location of the
existing eCopy (e.g., CD, DVD, or flash drive) by clicking Choose Folder. Once you have
selected the location of your eCopy, you click Run Analysis. This tool runs through all of
the technical standards described in Attachment 1 and either confirms that the eCopy meets
the technical requirements or provides the reasons that it does not meet the technical
requirements. If you do encounter an error, repackage the submission and use the validator
tool to verify the format again, before sending to FDA.
Tip to Sponsors: It is recommended that you use the eCopy Validation Module to check the final
eCopy on the CD, DVD, or flash drive before submitting it to FDA in order to identify any burning
errors or hidden ghost files that may cause an eCopy to fail the eCopy Loader used by FDA.
Figure 2: Snapshot of initial screen of eCopies Validator tool
j. How do you submit an eCopy to FDA?
An eCopy is submitted as part of a package to CDRH’s or CBER’s DCC. The package
includes:
•
one or more eCopies burned to a CD, DVD, or flash drive with a paper copy of your
company cover letter. The company cover letter must include an eCopy statement
and signature as described in Section A of Attachment 1. If more than one eCopy is
to be submitted, then a single company cover letter for all eCopies is sufficient; and
•
one complete paper copy.
For Third Party 510(k)s, refer to Section 7f for the specifics of the eCopy and company cover
letter associated with each of the two parties involved.
13
k. How does FDA process an eCopy?
The determination as to whether or not an eCopy passes the loading process will be made by
the appropriate staff at the same time the submission is received by FDA and logged into our
database. 24
If an eCopy passes the loading process, the company cover letter and eCopy contents will be
loaded into the appropriate Center’s official submission repository.
If an eCopy fails the loading process, we will notify you in writing (e.g., by letter, email,
and/or fax) that your submission is on eCopy hold. The eCopy hold notification will
describe the reasons for the eCopy failure and the logistics for submitting a replacement
eCopy. It is important that you follow these directions to avoid delays in processing the
replacement eCopy. The submission will be placed and remain on eCopy hold until a
valid replacement eCopy is submitted to FDA and verified to meet the technical
standards of Attachment 1. 25
l. What do you provide to FDA in response to an eCopy hold?
As stated above, you will receive a notification that states the specific reason(s) why your
eCopy failed the loading process. In response to the eCopy hold notification, you must
provide:
•
a company cover letter with an eCopy statement and signature (preferably with a
revised date); and
•
a replacement eCopy (CD, DVD, or flash drive) that meets the technical standards of
Attachment 1. Be sure to label the media with the full submission number and
identify it as a “replacement eCopy.”
Be sure that you provide a complete eCopy for the submission at hand and not just the
corrected files or folders. 26
The company cover letter (with an eCopy statement and signature) is required regardless of
whether or not the eCopy failure was related to the company cover letter, because the DCC
needs to be able to date stamp the company cover letter to record the receipt date of the
replacement eCopy.
24
At CDRH, it is managed by the DCC staff. At CBER, it is managed jointly by the DCC staff and the Regulatory
Project Manager (RPM).
25
Do not confuse an “eCopy hold” with a User Fee hold; a submission may be placed on User Fee hold for failure
to pay the User Fee even if a valid eCopy is submitted. In addition, do not confuse an “eCopy hold” with FDA
decisions such as Refuse to Accept or Refuse to File. An eCopy hold takes place before a submission is subject to
any review process. Once under review, if applicable for that submission type, acceptance and/or filing reviews
will be performed. See also Section 7m of this guidance.
26
For eCopies submitted to CBER only, in some cases only those files that could not be uploaded need to be
resubmitted. If you have been advised by the CBER RPM that a submission tracking number has been assigned to
your submission, the new eCopy and its company cover letter should clearly identify the assigned submission
tracking number and state that the eCopy is an amendment to that submission.
14
Please note that if the only reason your eCopy failed is because of a lack of a signature or an
adequate eCopy statement on your company cover letter, then all you need to provide is a
paper copy of your revised company cover letter in response to the eCopy hold notification.
m. How does FDA process a replacement eCopy?
When FDA receives a replacement eCopy, it is processed in the same manner as the initial
eCopy. More specifically, a determination is made as to whether or not the replacement
eCopy passes the loading process. If it does not, then the submission will be placed on
eCopy hold again, and an eCopy hold notification will be issued to you.
n. What timeframes need to be considered?
If you are submitting a new submission and receive an eCopy hold notification, you should
respond to that eCopy hold notification within 180 days. If FDA does not receive a
replacement eCopy within 180 days of the eCopy hold notification, FDA may consider your
submission withdrawn and closed in our database.
If you are submitting a response to a review hold notification (e.g., a response to an
Additional Information letter for a 510(k)), you should allow for mail delivery and eCopy
processing times in order to ensure that you meet review hold notification deadlines. You
risk withdrawal and closure of your submission if your response is mailed very close to or at
180 days.
o. When does review of a submission begin?
Review of a submission will begin only after a valid eCopy has been received and, if
applicable, the user fee has been paid. 27
p. If you submitted an eCopy for a submission type that did not require an
eCopy and you received an eCopy hold letter, what are your options?
If you submitted an eCopy for a compassionate use IDE, emergency use IDE, EUA, MAF,
513(g), or CLIA X file, and it did not meet the technical standards in Attachment 1, your
submission will be placed on eCopy hold. However, unlike the other submission types that
require a valid eCopy, you have the option of responding to that eCopy hold notification with
an additional paper copy in lieu of a replacement eCopy.
27
As applicable for the submission type, acceptance or acceptance and filing reviews will then be conducted.
Otherwise, the substantive review of the submission will begin. For more information, please see the guidances
“FDA and Industry Actions on Premarket Notification (510(k)) Submissions: Effect on FDA Review Clock and
Goals” (http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm089735.htm)
and “Guidance for Industry and Food and Drug Administration Staff - FDA and Industry Actions on Premarket
Approval Applications (PMAs): Effect on FDA Review Clock and Goals”
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm089733.htm).
15
8. What if your device is regulated by CBER?
a. Will the new eCopy requirements apply?
Yes, unless your submission is an entirely electronic submission exempted under this
guidance, as described below. With the implementation of the statutory requirement, all
medical device submission types listed in Section 4, as well as all subsequent submissions to
an original submission, including amendments, supplements, and reports (reports include
annual/periodic and post-approval reports), must be in the form of an eCopy regardless of the
Center in FDA in which the submission will be reviewed unless the requirement is waived or
exempted. Accordingly, submissions for devices subject to review by CBER must be in the
form of an eCopy, except where exempted as described below.
Submissions for devices that are subject to licensure under the Public Health Service (PHS)
Act, including biologics license applications and supplements, investigational new drug
applications, and EUAs for these devices, may be submitted as true electronic submissions as
detailed in Section 8b and Section 8c below. FDA will exempt such true electronic
submissions from the eCopy requirement.
b. Can you submit an electronic submission instead of an eCopy?
Yes, you can choose to make true electronic submissions (described below) and submit them
through the FDA Gateway.
c. How do you prepare and submit an electronic submission to CBER?
CBER has several resources available to applicants who choose to submit electronic
submissions as outlined in the document “Regulatory Submissions in Electronic Format for
Biologic Products.”
(http://www.fda.gov/BiologicsBloodVaccines/DevelopmentApprovalProcess/ucm163685.ht
m). Thus, specific details are available in the cited references and will not be repeated in this
guidance.
In addition, for devices that are regulated under the PHS Act and require the submission of a
BLA, consult the guidance document entitled “Providing Regulatory Submissions to the
Center for Biologics Evaluation and Research (CBER) in Electronic Format - Biologics
Marketing Applications”
(http://www.fda.gov/downloads/BiologicsBloodVaccines/GuidanceComplianceRegulatoryIn
formation/Guidances/General/UCM192413.pdf) for details on preparing your electronic
submission. Note that certain sections of this guidance, for example, those on pharmacology
and toxicology, are generally not pertinent to licensed devices.
Also note that true electronic submissions, as described in the above-referenced guidance
documents, cannot include zip files, as can be done with eCopies.
You can submit questions pertaining to the preparation of submissions in electronic format
for submission to CBER at [email protected].
16
You may also contact CBER at [email protected] to discuss the potential for
submission of data in CDISC format
(http://www.fda.gov/BiologicsBloodVaccines/DevelopmentApprovalProcess/ucm209137.ht
m).
CBER will accept true electronic submissions via electronic transmission (i.e., through the
FDA Electronic Submissions Gateway 28,29) or on physical media through CBER’s Document
Control Center. CBER will accept eCopies only on physical media through our DCC; they
cannot be submitted through the FDA Gateway.
28
Refer to “Food and Drug Administration Electronic Submissions Gateway (Federal Register Notice) - 8/9/2006”
(http://www.gpo.gov/fdsys/pkg/FR-2006-08-08/html/E6-12808.htm).
29
Refer to “Electronic Submissions Gateway”
(http://www.fda.gov/ForIndustry/ElectronicSubmissionsGateway/default.htm).
17
Attachment 1 – Technical Standards for eCopies
Below are the standards that are written into the FDA eCopy software coding. If an eCopy does
not meet all of the required standards identified in Sections A through D below, then the eCopy
will not pass FDA’s eCopy loading process.
The basic steps for developing an eCopy are as follows: 30
1. Determine the content of your document (original, supplement, amendment, or report).
This is not dictated by the eCopy program.
2. Create your company cover letter following the specific requirements in Section A.
Make sure your company cover letter includes an eCopy statement and signature.
3. Based on the content, determine whether you want to have a volume-based or nonvolume-based structure for your eCopy. This determination is made independently for
each eCopy and is not dependent on the format chosen for any previous document. See
Section B below.
If you chose a volume-based submission, then add your volumes to the eCopy following
the naming convention in Section B below.
4. Create your PDFs and add them to the eCopy. PDFs are the main file type, if not the
only file type, that comprises your eCopy. Please note that PDFs should be created by
converting the files from the original (native) format (e.g., Microsoft Word) using Adobe
Acrobat PDF Version 11 or below whenever possible, rather than creating them as
scanned versions of the printed files, which are far inferior in quality.
For the naming convention for PDFs, follow the specifics in Section C, Part 1. Do not
name a PDF using the volume/folder naming convention as the two differ from each
other.
PDFs can only be added to the root level 31 of the eCopy or under a volume/folder as
shown in Figures 3 through 12 below. If you have a volume-based submission, then your
PDFs must be named with the prefix count starting with “001_” in each volume (001_,
002_, etc.) as shown in Figure 10 and Figure 11below.
You may have a single PDF that comprises your eCopy if it meets all of the standards in
Section C, including the naming convention. The single PDF must have a “001_” prefix.
Please note that the file size limit, in particular, must be taken into consideration if you
are contemplating using a single PDF; see Section C, Part 4 below for details.
30
This section is a simple summary of the process for creating an eCopy. It is critical that you read and understand
all of the technical standards addressed in Attachment 1.
31
The “root level” of an eCopy is defined is the main level that you see when you open a CD, DVD, or flash drive.
18
Aside from naming convention, do not forget the other PDF standards that you need to
meet: (1) Adobe Acrobat PDF version 11 or below; (2) no embedded attachments; (3) no
security settings; and (4) 50MB or smaller in size.
5. If you need to add non-PDFs to your eCopy, follow the instructions in Section D. NonPDF files are added by zipping them and placing the zip file(s) under a “MISC FILES” or
“STATISTICAL DATA” folder. Do not place any PDFs in either of these two folders.
Please note that it is preferable that statistical data be provided in a structured format
readable by common statistical analysis software packages.
6. Prepare your package for DCC. The package includes: (1) your eCopy(ies) burned to a
CD, DVD, or flash drive with a paper copy of your company cover letter as described in
Section A below and (2) one full paper copy.
7. Mail your package to the DCC.
Tip to Sponsors: It is recommended that you provide adequate protection for the CD, DVD, or flash
drive to prevent physical harm during transport. Consider sending the package via registered mail.
A. Company Cover Letter Requirements
To meet the standards of the eCopy program, the cover letter must also include both:
• a signature (may be a wet (i.e., ink) signature or a valid digital signature); and
• one of the following eCopy statements:
o standard text – “The eCopy is an exact duplicate of the paper copy.”; or
o modified text – “The eCopy is an exact duplicate of the paper copy except [specify all
differences].”
Do not confuse a company cover letter with Form FDA 3514 (CDRH Premarket Review
Submission Cover Sheet). A company cover letter is the document that is on your letterhead and
includes information such as the purpose of your submission, 32 contact information (including
phone number and email address), along with the eCopy statement and your signature.
We expect the vast majority of the submissions to include the first statement (standard text).
However, as described in Section 3 above, for those submissions that contain certain clinical
datasets, or other types of data/information that are not feasible or practical to put in paper form,
the second statement (modified text) would apply. If you include the second eCopy statement
(modified text), you must specify the differences between the eCopy and paper submission. In
addition, you must include a placeholder in the paper submission referring to the eCopy for that
32
When describing the purpose of your submission, please use characteristics such as the submission type (e.g.,
510(k), PMA, Pre-Submission), stage of review (i.e., original, amendment, supplement, or report), and any other
key words or information that will assist in FDA’s processing of the submission. It is especially important to
include the submission tracking number if one has already been assigned and provided to you.
19
specific information (e.g., “The eCopy is an exact duplicate of the paper copy except that data
line listings were only provided in the eCopy. A placeholder was provided in Volume 4 of the
paper copy referring back to the eCopy for that information.”).
Please also note that it is FDA’s preference that responses to deficiencies identified during
submission review not be incorporated into the company cover letter for ease of processing on
both the part of the applicant and FDA. Instead, please incorporate your responses into the main
body of your submission.
It is recommended that your company cover letter (with the eCopy statement and signature) also
be included as a PDF in your eCopy, but it is not required.
B. Volume or Non-Volume Structure Requirements
The structure of an eCopy is highly dependent on the overall size of the submission and can be
organized as a volume-based or non-volume-based submission as described below. Although
there is no maximum total submission size restriction, it is recommended that the total package
submission not exceed 1 GB to avoid possible load time failures that may delay the submission
process.
1. Non-Volume-Based eCopy
A non-volume based eCopy is generally recommended for small submissions. This eCopy
structure includes one or more PDFs at the root level. See Section C for required PDF file
technical standards, particularly the required PDF naming convention. Examples of
non-volume-based eCopies are shown in Figures 3 through 9 below.
Figure 3: Pre-Submission for which all content was was placed in a single PDF
Figure 4: PMA annual report for which all content was was placed in a single PDF
Figure 5: Original 510(k) submission for which all content was placed in a single PDF
20
Figure 6: Original 510(k) submission for which the content was added as individual PDF
files
Figure 7: Response to 510(k) RTA hold letter for which each item being responded to was
added as an individual PDF file
21
Figure 8: Response to a 510(k) deficiency letter for which for which all content was placed
in a single PDF
Figure 9: Response to a deficiency letter with each response as its own PDF
2. Volume-Based eCopy
A volume-based eCopy is generally recommended for large or complex submissions in order
to facilitate the review of the submission. This eCopy structure includes volumes (i.e.,
folders) at the root level. Each volume, in turn, includes one or more PDF files. No other
file types but PDFs can be placed in these volumes.
A naming convention for the volumes is required in order to assure that the system can create
a sort order of the folders. Without this sort order, the volumes will load in alphabetical
order and, thus, be out of order.
Each volume must have the following naming convention:
• VOL_xxx_Descriptive Name (e.g., VOL_001_Mechanical Testing); or
• VOL_xxx (e.g., VOL_001).
The volume numbering must have a non-repeating, consecutive prefix. The first
volume has the prefix of VOL_001. The second volume has a prefix of VOL_002, etc.
If this volume naming convention is not followed, the eCopy will fail the loading
process.
The Descriptive Name part of the name of the volumes is optional. However, if a
Descriptive Name is used for a volume, it should be descriptive of its content and meaningful
to the reviewer. The Descriptive Name can be up to 125 characters and can have spaces,
dashes (not elongated dashes), underscores, and periods. However, the Descriptive Name
must not contain any of the following special characters or non-English letters or it will
fail the loading process:
22
•
•
•
•
•
•
•
•
tilde (~)
asterisk (*);
elongated dash (–);
apostrophe (’);
single quotation mark (‘);
double quotation marks (“);
colon (:);
pound sign (#);
•
•
•
•
•
•
•
vertical bar (|);
forward slash (/);
backward slash (\);
greater than sign (>);
less than sign (<);
question mark (?); and
various other symbols (e.g.,
→,*,β,α,∞,±,™).
No Subfolders: Under this eCopy structure, you must avoid placing any subfolders under a
volume or the eCopy will fail the loading process. Even if you have non-PDF documents
that are associated with a particular volume, you cannot embed the “MISC FILES” or
“STATISTICAL DATA” folder within one of these volumes or it will fail the eCopy
loading.
NOTE: A slight variation of a volume-based eCopy structure includes both volumes and at
least one PDF file at the root level. This structure commonly occurs when an applicant adds
a PDF of the company cover letter at the root level with all other PDFs organized under
multiple volumes. See Figure 12 as one example.
23
Examples of volume-based eCopies are shown in Figures 10 through 12 below.
Figure 10: Original PMA with the PDF content of VOL_001 and VOL_002 shown
Figure 11: Original IDE with the PDF content of VOL_002 and VOL_003 shown
24
Figure 12: Response to RTA hold notification for which the responses were grouped by
topic
C. PDF File Requirements
Whether you choose a volume-based or non-volume-based eCopy structure, PDF is the primary
file format used for an eCopy. (See Section D for how to add non-PDF files to an eCopy.)
Below are the requirements for PDF files. If you do not follow them, your eCopy will fail
the loading process.
NOTE: You may choose to have a single PDF that comprises the entire submission, as long as
all PDF file requirements below are met. However, it is important to note that, as described in
Section C, Part 4 below, no individual PDF file may exceed 50MB. Also keep in mind that large
files take longer to open and search than do small files. A very large file can be difficult for
reviewers to work with, unless there are bookmarks or hyperlinks. See Section C, Part 4 below
for details.
1. Specific PDF File Naming Convention
Regardless of which eCopy structure is used, a naming convention is required in order to
assure that the loading system can create a sort order of PDF files that matches the order of
files to be read by review staff. Without this sort order, the files will load in alphabetical
order and, thus, be out of order.
You must use the following naming convention for all PDF files, whether part of a
volume-based or non-volume-based eCopy:
•
xxx_Descriptive Name
The PDF file name has a non-repeating, consecutive 3-digit number prefix followed by
an underscore (_). The first PDF has the prefix of 001_, the second PDF has a prefix of
002_, etc. Keep in mind that if you have a volume-based submission, you need to start over
with the numbering of the PDFs at 001_, 002_, etc. within each volume, as shown in Figure
10 and Figure 11 above. If this PDF file naming convention is not followed, the eCopy
will fail the loading process.
eCopies that are comprised of only a single PDF need to have the 3-digit prefix of 001_.
25
The Descriptive Name part of the file name should be descriptive of its content and
meaningful to the reviewers. The Descriptive Name can be up to 125 characters and can
have spaces, dashes (not elongated dashes), underscores, and periods. However, the
Descriptive Name must not contain any of the following special characters or nonEnglish letters or it will fail the loading process:
•
•
•
•
•
•
•
•
tilde (~)
asterisk (*);
elongated dash (–);
apostrophe (’);
single quotation mark (‘);
double quotation marks (“);
colon (:);
pound sign (#);
•
•
•
•
•
•
•
vertical bar (|);
forward slash (/);
backward slash (\);
greater than sign (>);
less than sign (<);
question mark (?); and
various other symbols (e.g.,
→,*,β,α,∞,±,™).
Examples of the PDF file names are throughout the figures in Attachment 1.
NOTE: There is no correlation between the 3-digit file name prefix and the content or
section location of the PDF file (e.g., a Section 10 response does not need a “010_” prefix).
The 3-digit prefix is only used by the loading software to load the PDFs in the correct order;
otherwise, the system would load the PDF files alphabetically. Depending on the Center
involved, the review staff may or may not even see the 3-digit prefix after it is loaded into
the official repository.
This is why it is important that you have meaningful Descriptive Names for your PDF files
so that it is clear to review staff what the content of the file involves. You can use the
Descriptive Name to also refer to Section or Tab numbers or review deficiency items. It is
recommended that you use Descriptive Names that are consistent with the language used in
published guidance documents. 33 This will facilitate the review process by allowing the
reviewer to easily navigate through the information. Examples of the varying Descriptive
Names for the PDF files are throughout the figures in Attachment 1.
2. No Embedded Attachments or Attributes
Our previous version of the eCopy software rejected PDF files with embedded attachments
and attributes. We found that the rejected PDF files were due to embedded attachments or
33
Examples of published guidances with helpful descriptions of submission contents include the recently published
guidance on Refuse to Accept Policy for 510(k)s
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm081752.htm),
CBER’s Guidance for Industry; Content and Format of Chemistry, Manufacturing and Controls Information and
Establishment Description Information for a Biological In Vitro Diagnostic Product
(http://www.fda.gov/downloads/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/Guidances/B
lood/ucm080819.pdf), and Guidance for the Content of Premarket Submissions for Software Contained in Medical
Devices,
(http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm089543.htm) as well
as many others.
26
attributes that the applicant did not intentionally embed and of which they were unaware.
Accordingly, in order to streamline the eCopy processing, we have updated our software to
not reject PDFs with embedded attachments or attributes. However, do not intentionally
embed attachments to PDF files because those embedded attachments are not
compatible with our official repository, which can result in this information being
missed during the review (e.g., we cannot search for content in an embedded
attachment in a PDF; the attachment is removed when a PDF is downloaded from the
official repository).
NOTE: Do not confuse embedded attachments or attributes with hyperlinks or bookmarks,
as these are very different. Hyperlinks and bookmarks are not only permitted, but are also
encouraged, because they facilitate navigation of the submission by the reviewer; they are
described in Section 7(b) above.
3. No PDFs that Require a Password to Open
We previously rejected PDF files with any type of security setting that met either of the
following two scenarios: (1) security settings that allowed anybody to open the file but
protected the content from modification (which appears to be a common practice with
independent laboratories) and (2) security settings that required passwords to open them.
We found that all of the rejected PDF files were due to the first scenario (i.e., PDFs that
could be opened but the content was protected). Accordingly, in order to streamline the
eCopy processing, we will now allow PDFs with this type of security setting. However, we
discourage submitting PDF files with any type of security setting, because this affects our
ability to redact Confidential Commercial Information efficiently.
However, you must not include any PDF that requires a password to open it or we will
put the submission on eCopy hold. eCopies must not include PDF files that require
passwords to view the content.
4. PDF File Size Limited to 50MB or Below
While there is no limitation on the total size of an eCopy, each PDF file must be limited to
50MB or smaller.
Be careful to look at the file size after you have added it to your eCopy media (CD, DVD, or
flash drive), as shown in Figure 13. The file size shown here is what the loading software
will use to determine if the size technical standard has been met. Do not use the size limit in
the file properties or the size limit that appears when you hover the cursor over a PDF file, as
both of these sizes will be smaller and will mislead you as to whether or not the PDF size
technical standard has been met.
27
Figure 13: PDF that has exceeded the 50MB size limit and will fail the eCopy loading
process
If a file size is greater than 50MB, then you must split the contents into multiple files. We
recommend that you name the files in a way that clearly reflects that it was originally a
single file that was split into multiple files. One suggested way of accomplishing this is by
naming the files as Parts 1 and 2 as shown in Figure 14 below.
Figure 14: Example of how you can split and label a PDF greater than 50MB into multiple
files
5. Adobe Acrobat PDF Version 11 or Below
Only eCopies submitted using Adobe Acrobat 11 or below will be accepted. 34 If you have a
new version of Adobe Acrobat greater than 11, you must save the PDF as a reduced size PDF
or the eCopy will fail the loading process.
D. Requirements for How to Add Non-PDF Files via “STATISTICAL DATA”
and “MISC FILES” Folders
Section B describes how both a volume-based and non-volume-based eCopy include PDF files.
However, in addition to PDF files, an eCopy may also include non-PDF files, if applicable for a
particular submission.
The three required steps for adding non-PDF files to an eCopy are as follows:
34
•
Add a “STATISTICAL DATA” or “MISC FILES” folder to the root level of the eCopy.
These folders must be spelled precisely, but they are not case sensitive.
•
Zip all non-PDF content into one or more zip file(s). There are no limitations/restrictions
on the naming convention for a zip file(s) or any of the content that you add to the zip
file(s). In addition, there is no size limit for a zip file.
•
While there is no size limit for a zip file, it is recommended that the total submission size
is limited to 1 GB or less.
•
Add the zip file(s) to the “STATISTICAL DATA” or “MISC FILES” folder.
As we test and validate new versions of Adobe Acrobat, we will update this guidance accordingly.
28
If you do not follow these requirements, the eCopy will fail the loading process.
NOTE: Depending on the type of non-PDF files that you want to add to your eCopy, you may
determine that it is appropriate to have both the “STATISTICAL DATA” and “MISC FILES”
folders in your eCopy. Figure 16 below illustrates this.
Below describes the type of appropriate information as part of a “STATISTICAL DATA” or
“MISC FILES” folder.
1. “STATISTICAL DATA” folder
The “STATISTICAL DATA” folder is used to add types of statistical information, including
metadata 35, data line listings and program codes, to the eCopy in their native formats, such
as, but not limited to: SAS; XPORT; XML; SGML; S-Plus; R files; ASCII; Molfiles; and
Excel. There are no restrictions on the format used; however, file formats that include
variable labels and dictionary information (such as SAS XPORT) are encouraged. 36
Do not forget to zip the content before placing it within the STATISTICAL DATA
folder.
2.
“MISC FILES” folder
The “MISC FILES” folder is used to add types of files that that cannot be submitted (or
should not be submitted) in PDF format and are not statistical in nature (e.g., videos, x-rays,
machine readable software source code). These miscellaneous files may be included in the
eCopy under the MISC FILES folder in their native formats, such as, but not limited to: .gif;
.tif; .jpg; .avi; .mpeg; .wmv; and .txt. There are no restrictions on the native format.
In addition, for the purposes of streamlining the review process, FDA encourages you to also
include, under the MISC FILES folder, Microsoft Word versions of certain documents or
pieces of information that were also provided in the main body of the eCopy as PDFs. In
other words, include the PDF version in the main body of the eCopy as part of the volumebased or non-volume-based eCopy structure and include a Microsoft Word version in the
MISC FILES folder to assist the reviewer. Do not include Microsoft Word versions in lieu
of the PDF versions. Documents such as those listed below are commonly requested via
Interactive Review to enable FDA feedback to the applicant and/or completion of the review.
Inclusion of these documents within the MISC FILES folder in an eCopy can help to
minimize potential delays during the substantive review of the submission. Suggested
documents include, as applicable:
35
Metadata includes data dictionaries and terminologies, formats, annotated case report forms, statistical analysis
details, and any other information that contributes to understanding and using the data.
36
For further information, see the final guidance, “Guidance for Industry: Providing Regulatory Submissions in
Electronic Format – Standardized Study Data”
(http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM292334.pdf).
29
•
•
•
•
•
Labeling for any submission [preferably with each piece (e.g., physician labeling,
patient labeling, operators manual) as a separate file];
Predicate device comparison table for 510(k)s;
510(k) Summary;
Summary of Safety and Effectiveness Data (SSED) for PMAs; and
Summary of Safety and Probable Benefit (SSPB) for HDEs.
There are no limitations/restrictions on the naming convention for any files you add to the
zip files for the MISC FILES folder. However, for Microsoft Word documents included in
the MISC FILES folder, it is recommended that you use a naming convention similar to the
PDF equivalent files so that reviewers can easily make the correlation.
Do not forget to zip the content before placing it within the MISC FILES folder.
Figure 15 provides an example of non-volume-based eCopy with a MISC FILES. Figure 16
provides an example of a volume-based eCopy that includes both the STATISTICAL DATA and
MISC FILES folders. Both figures show the zip file(s) directly under the folder.
30
Figure 15: Example of a non-volume-based submission with a “MISC FILES” folder
Figure 16: Example of a volume-based submission with “MISC FILES” and “STATISTICAL
DATA” folders
31
File Type | application/pdf |
File Title | Attachment E CDRH Final Guidance Cover Sheet |
Author | OHIP Info Systems |
File Modified | 2018-04-03 |
File Created | 2015-12-03 |