eCFR for 30 CFR 250, subpart B

eCFR — Code of Federal Regulations.pdf

30 CFR 250, Subpart B, Plans and Information

eCFR for 30 CFR 250, subpart B

OMB: 1014-0024

Document [pdf]
Download: pdf | pdf
eCFR — Code of Federal Regulations

Home

gpo.gov

govinfo.gov

 

Electronic Code of Federal Regulations
e-CFR data is current as of February 12, 2018

Browse / Search Previous

e-CFR Navigation Aids
Browse
Simple Search

Title 30 → Chapter II → Subchapter B → Part 250 → Subpart B
Browse Previous | Browse Next

Advanced Search
 — Boolean
 — Proximity
 
Search History
Search Tips
Corrections
Latest Updates
User Info
FAQs
Agency List
Incorporation By Reference

Title 30: Mineral Resources

PART 250—OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF

Related Resources

Post-ApproVal Requirements for the EP, DPP, and DOCD

The Code of Federal Regulations (CFR)
annual edition is the codification of the
general and permanent rules published in
the Federal Register by the departments
and agencies of the Federal Government
produced by the Office of the Federal
Register (OFR) and the Government
Publishing Office.
Download the Code of Federal
Regulations in XML.
Download the Electronic Code of Federal
Regulations in XML.
Parallel Table of Authorities and Rules for
the Code of Federal Regulations and the
United States Code
Text | PDF
Find, review, and submit comments on
Federal rules that are open for comment
and published in the Federal Register
using Regulations.gov.
Purchase individual CFR titles from the
U.S. Government Online Bookstore.
Find issues of the CFR (including issues
prior to 1996) at a local Federal depository
library.
[A1]

Subpart B—Plans and Information
Contents
General Information
§250.200   Definitions.
§250.201   What plans and information must I submit before I conduct any activities on my lease or unit?
§§250.202-250.203   [Reserved]
§250.204   How must I protect the rights of the Federal government?
§250.205   Are there special requirements if my well affects an adjacent property?

§250.282   Do I have to conduct post-approval monitoring?
Deepwater Operations Plan (DWOP)
§250.286   What is a DWOP?
§250.287   For what development projects must I submit a DWOP?
§250.288   When and how must I submit the Conceptual Plan?
§250.289   What must the Conceptual Plan contain?
§250.290   What operations require approval of the Conceptual Plan?
§250.291   When and how must I submit the DWOP?
§250.292   What must the DWOP contain?
§250.293   What operations require approval of the DWOP?
§250.294   May I combine the Conceptual Plan and the DWOP?
§250.295   When must I revise my DWOP?
Back to Top

GENEraL INfOrMaTiON
Back to Top

§250.200   Definitions.
Acronyms and terms used in this subpart have the following meanings:
(a) Acronyms used frequently in this subpart are listed alphabetically below:
BOEM means Bureau of Ocean Energy Management of the Department of the Interior.
BSEE means Bureau of Safety and Environmental Enforcement of the Department of the Interior.
CID means Conservation Information Document.

file:///ISESTRNAS01/BSEE/ORP/EXPLICIT/RegStanBR/INFORMATION COLLECTION/0024 - B/2018/eCFR — Code of Federal Regulations.html[2/14/2018 10:16:52 AM]

eCFR — Code of Federal Regulations

CZMA means Coastal Zone Management Act.
DOCD means Development Operations Coordination Document.
DPP means Development and Production Plan.
DWOP means Deepwater Operations Plan.
EIA means Environmental Impact Analysis.
EP means Exploration Plan.
NPDES means National Pollutant Discharge Elimination System.
NTL means Notice to Lessees and Operators.
OCS means Outer Continental Shelf.
(b) Terms used in this subpart are listed alphabetically below:
Amendment means a change you make to an EP, DPP, or DOCD that is pending before BOEM for a decision (see 30 CFR
550.232(d) and 550.267(d)).
Modification means a change required by the Regional Supervisor to an EP, DPP, or DOCD (see 30 CFR 550.233(b)(2)
and 550.270(b)(2)) that is pending before BOEM for a decision because the OCS plan is inconsistent with applicable
requirements.
New or unusual technology means equipment or procedures that:
(1) Have not been used previously or extensively in a BSEE OCS Region;
(2) Have not been used previously under the anticipated operating conditions; or
(3) Have operating characteristics that are outside the performance parameters established by this part.
Non-conventional production or completion technology includes, but is not limited to, floating production systems, tension
leg platforms, spars, floating production, storage, and offloading systems, guyed towers, compliant towers, subsea manifolds,
and other subsea production components that rely on a remote site or host facility for utility and well control services.
Offshore vehicle means a vehicle that is capable of being driven on ice.
Resubmitted OCS plan means an EP, DPP, or DOCD that contains changes you make to an OCS plan that BOEM has
disapproved (see 30 CFR 550.234(b), 550.272(a), and 550.273(b)).
Revised OCS plan means an EP, DPP, or DOCD that proposes changes to an approved OCS plan, such as those in the
location of a well or platform, type of drilling unit, or location of the onshore support base (see 30 CFR 550.283(a)).
Supplemental OCS plan means an EP, DPP, or DOCD that proposes the addition to an approved OCS plan of an activity
that requires approval of an application or permit (see 30 CFR 550.283(b)).
Back to Top

§250.201   What plans and information must I submit before I conduct any activities on my lease or unit?
(a) Plans and documents. Before you conduct the activities on your lease or unit listed in the following table, you must
submit, and BSEE must approve, the listed plans and documents. Your plans and documents may cover one or more leases or
units.
You must submit
a(n) .  .  .
(1) [Reserved]
(2) [Reserved]
(3) [Reserved]
(4) Deepwater
Operations Plan
(DWOP),
(5) [Reserved]
(6) [Reserved]

Before you .  .  .

Conduct post-drilling installation activities in any water depth associated with a development project
that will involve the use of a non-conventional production or completion technology.

(b) Submitting additional information. On a case-by-case basis, the Regional Supervisor may require you to submit
additional information if the Regional Supervisor determines that it is necessary to evaluate your proposed plan or document.
(c) Limiting information. The Regional Director may limit the amount of information or analyses that you otherwise must
provide in your proposed plan or document under this subpart when:
(1) Sufficient applicable information or analysis is readily available to BSEE;
(2) Other coastal or marine resources are not present or affected;

file:///ISESTRNAS01/BSEE/ORP/EXPLICIT/RegStanBR/INFORMATION COLLECTION/0024 - B/2018/eCFR — Code of Federal Regulations.html[2/14/2018 10:16:52 AM]

eCFR — Code of Federal Regulations

(3) Other factors such as technological advances affect information needs; or
(4) Information is not necessary or required for a State to determine consistency with their CZMA Plan.
(d) Referencing. In preparing your proposed plan or document, you may reference information and data discussed in other
plans or documents you previously submitted or that are otherwise readily available to BSEE.
Back to Top

§§250.202-250.203   [Reserved]
Back to Top

§250.204   How must I protect the rights of the Federal government?
(a) To protect the rights of the Federal government, you must either:
(1) Drill and produce the wells that the Regional Supervisor determines are necessary to protect the Federal government
from loss due to production on other leases or units or from adjacent lands under the jurisdiction of other entities (e.g., State
and foreign governments); or
(2) Pay a sum that the Regional Supervisor determines as adequate to compensate the Federal government for your failure
to drill and produce any well.
(b) Payment under paragraph (a)(2) of this section may constitute production in paying quantities for the purpose of
extending the lease term.
(c) You must complete and produce any penetrated hydrocarbon-bearing zone that the Regional Supervisor determines is
necessary to conform to sound conservation practices.
Back to Top

§250.205   Are there special requirements if my well affects an adjacent property?
For wells that could intersect or drain an adjacent property, the Regional Supervisor may require special measures to
protect the rights of the Federal government and objecting lessees or operators of adjacent leases or units.
Back to Top

POsT-ApprOVaL REQUirEMENTs fOr ThE EP, DPP, aNd DOCD
Back to Top

§250.282   Do I have to conduct post-approval monitoring?
The Regional Supervisor may direct you to conduct monitoring programs. You must retain copies of all monitoring data
obtained or derived from your monitoring programs and make them available to BSEE upon request. The Regional Supervisor
may require you to:
(a) Monitoring plans. Submit monitoring plans for approval before you begin work; and
(b) Monitoring reports. Prepare and submit reports that summarize and analyze data and information obtained or derived
from your monitoring programs. The Regional Supervisor will specify requirements for preparing and submitting these reports.
Back to Top

DEEpwaTEr OpEraTiONs PLaN (DWOP)
Back to Top

§250.286   What is a DWOP?
(a) A DWOP is a plan that provides sufficient information for BSEE to review a deepwater development project, and any
other project that uses non-conventional production or completion technology, from a total system approach. The DWOP does
not replace, but supplements other submittals required by the regulations such as BOEM Exploration Plans, Development and

file:///ISESTRNAS01/BSEE/ORP/EXPLICIT/RegStanBR/INFORMATION COLLECTION/0024 - B/2018/eCFR — Code of Federal Regulations.html[2/14/2018 10:16:52 AM]

eCFR — Code of Federal Regulations

Production Plans, and Development Operations Coordination Documents. BSEE will use the information in your DWOP to
determine whether the project will be developed in an acceptable manner, particularly with respect to operational safety and
environmental protection issues involved with non-conventional production or completion technology.
(b) The DWOP process consists of two parts: a Conceptual Plan and the DWOP. Section 250.289 prescribes what the
Conceptual Plan must contain, and §250.292 prescribes what the DWOP must contain.
Back to Top

§250.287   For what development projects must I submit a DWOP?
You must submit a DWOP for each development project in which you will use non-conventional production or completion
technology, regardless of water depth. If you are unsure whether BSEE considers the technology of your project nonconventional, you must contact the Regional Supervisor for guidance.
Back to Top

§250.288   When and how must I submit the Conceptual Plan?
You must submit four copies, or one hard copy and one electronic version, of the Conceptual Plan to the Regional Director
after you have decided on the general concept(s) for development and before you begin engineering design of the well safety
control system or subsea production systems to be used after well completion.
Back to Top

§250.289   What must the Conceptual Plan contain?
In the Conceptual Plan, you must explain the general design basis and philosophy that you will use to develop the field.
You must include the following information:
(a) An overview of the development concept(s);
(b) A well location plat;
(c) The system control type (i.e., direct hydraulic or electro-hydraulic); and
(d) The distance from each of the wells to the host platform.
Back to Top

§250.290   What operations require approval of the Conceptual Plan?
You may not complete any production well or install the subsea wellhead and well safety control system (often called the
tree) before BSEE has approved the Conceptual Plan.
Back to Top

§250.291   When and how must I submit the DWOP?
You must submit four copies, or one hard copy and one electronic version, of the DWOP to the Regional Director after you
have substantially completed safety system design and before you begin to procure or fabricate the safety and operational
systems (other than the tree), production platforms, pipelines, or other parts of the production system.
Back to Top

§250.292   What must the DWOP contain?
You must include the following information in your DWOP:
(a) A description and schematic of the typical wellbore, casing, and completion;
(b) Structural design, fabrication, and installation information for each surface system, including host facilities;
(c) Design, fabrication, and installation information on the mooring systems for each surface system;
(d) Information on any active stationkeeping system(s) involving thrusters or other means of propulsion used with a surface
system;
(e) Information concerning the drilling and completion systems;

file:///ISESTRNAS01/BSEE/ORP/EXPLICIT/RegStanBR/INFORMATION COLLECTION/0024 - B/2018/eCFR — Code of Federal Regulations.html[2/14/2018 10:16:52 AM]

eCFR — Code of Federal Regulations

(f) Design and fabrication information for each riser system (e.g., drilling, workover, production, and injection);
(g) Pipeline information;
(h) Information about the design, fabrication, and operation of an offtake system for transferring produced hydrocarbons to
a transport vessel;
(i) Information about subsea wells and associated systems that constitute all or part of a single project development
covered by the DWOP;
(j) Flow schematics and Safety Analysis Function Evaluation (SAFE) charts (API RP 14C, subsection 4.3c, incorporated by
reference in §250.198) of the production system from the Surface Controlled Subsurface Safety Valve (SCSSV) downstream to
the first item of separation equipment;
(k) A description of the surface/subsea safety system and emergency support systems to include a table that depicts what
valves will close, at what times, and for what events or reasons;
(l) A general description of the operating procedures, including a table summarizing the curtailment of production and
offloading based on operational considerations;
(m) A description of the facility installation and commissioning procedure;
(n) A discussion of any new technology that affects hydrocarbon recovery systems;
(o) A list of any alternate compliance procedures or departures for which you anticipate requesting approval;
(p) If you propose to use a pipeline free standing hybrid riser (FSHR) on a permanent installation that utilizes a critical
chain, wire rope, or synthetic tether to connect the top of the riser to a buoyancy air can, provide the following information in
your DWOP in the discussions required by paragraphs (f) and (g) of this section:
(1) A detailed description and drawings of the FSHR, buoy and the tether system;
(2) Detailed information on the design, fabrication, and installation of the FSHR, buoy and tether system, including pressure
ratings, fatigue life, and yield strengths;
(3) A description of how you met the design requirements, load cases, and allowable stresses for each load case according
to API RP 2RD (as incorporated by reference in §250.198);
(4) Detailed information regarding the tether system used to connect the FSHR to a buoyancy air can;
(5) Descriptions of your monitoring system and monitoring plan to monitor the pipeline FSHR and tether for fatigue, stress,
and any other abnormal condition (e.g., corrosion) that may negatively impact the riser or tether; and
(6) Documentation that the tether system and connection accessories for the pipeline FSHR have been certified by an
approved classification society or equivalent and verified by the CVA required in subpart I of this part; and
(q) Payment of the service fee listed in §250.125.
[76 FR 64462, Oct. 18, 2011, as amended at 81 FR 26017, Apr. 29, 2016]

Back to Top

§250.293   What operations require approval of the DWOP?
You may not begin production until BSEE approves your DWOP.
Back to Top

§250.294   May I combine the Conceptual Plan and the DWOP?
If your development project meets the following criteria, you may submit a combined Conceptual Plan/DWOP on or before
the deadline for submitting the Conceptual Plan.
(a) The project is located in water depths of less than 400 meters (1,312 feet); and
(b) The project is similar to projects involving non-conventional production or completion technology for which you have
obtained approval previously.
Back to Top

§250.295   When must I revise my DWOP?
You must revise either the Conceptual Plan or your DWOP to reflect changes in your development project that materially
alter the facilities, equipment, and systems described in your plan. You must submit the revision within 60 days after any
material change to the information required for that part of your plan.

file:///ISESTRNAS01/BSEE/ORP/EXPLICIT/RegStanBR/INFORMATION COLLECTION/0024 - B/2018/eCFR — Code of Federal Regulations.html[2/14/2018 10:16:52 AM]

eCFR — Code of Federal Regulations

Back to Top
Need assistance?

file:///ISESTRNAS01/BSEE/ORP/EXPLICIT/RegStanBR/INFORMATION COLLECTION/0024 - B/2018/eCFR — Code of Federal Regulations.html[2/14/2018 10:16:52 AM]


File Typeapplication/pdf
File TitleeCFR — Code of Federal Regulations
File Modified2018-02-14
File Created2018-02-14

© 2024 OMB.report | Privacy Policy