5900-476 Instructions for STR0200: Gasoline, Gasoline Blendstock,

Fuels Regulatory Streamlining (Final Rule)

fuels_batch_annual_report_corrected

Fuels Regulatory Streamlining

OMB: 2060-0731

Document [pdf]
Download: pdf | pdf
OMB Control No. ####-####
Expires: ##/##/####

Instructions for STR0200: Gasoline, Gasoline Blendstock, and Diesel Batch Report
Who must report
Any of the following entities for each of its facilities must report on a per-batch basis for gasoline,
gasoline blendstocks and ULSD with sulfur greater than 15 ppm.








Gasoline manufacturers
Transmix processors
Oxygenate producers
Certified pentane producers
Certified pentane blenders
Certified butane blenders
Diesel manufacturers that produce ULSD with sulfur greater than 15 ppm

A separate batch report must be submitted for each batch of product produced or imported during the
averaging period.

Reporting requirements



40 CFR 1090 subpart J provides key requirements and reporting information (available at [link to
ECFR.gov]).
Special instructions for oxygenate reporting
o For RBOB or CBOB, report the percentage of oxygenate in the handblend created under
1090.1340. See 1090.905(c)(2)(ix)

o For RFG or CG where the fuel manufacturer does not account for the addition of
downstream oxygenate, measure and report if the gasoline contains oxygenate.
See 1090.905(c)(1)(ix)
o If blending manufacturers and transmix processors are required to measure and
report the volume of oxygenate under 1090.1310(e), report the measured value in
the comments field.






Special instructions for certified butane blending reporting – Butane reports are a combination of
two reports with two separate batch IDs to include:
o Butane batch – volume and properties of only the butane blendstock (reported as product
type “BU”) as received by the butane producer
o PCG + butane or the properties of the finished batch of gasoline (reported as product type
“BC” or “BX”)
Special instructions for certified pentane blending reporting – Pentane reports are a combination
of two reports with two separate batch IDs to include:
o Pentane batch – volume and properties of only the pentane blendstock (reported as
product type “PU”) as received by the pentane producer
o PCG + pentane or the properties of the finished batch of gasoline (reported as product
type “PC” or “PX”)
o Certified pentane producers are also required to report each batch of certified pentane
produced (reported as product type PP).
Special instructions for diesel manufacturers producing ULSD with sulfur greater than 15 ppm

EPA Form 5900-476

Page 1 of 11

OMB Control No. ####-####
Expires: ##/##/####

For any ULSD batch with a sulfur test result greater than 15 ppm, report the facility ID,
production date, batch ID, batch volume and sulfur parameter test result
o Enter “NA” for other gasoline specific parameters (i.e, RVP)
Special instructions for blending manufacturers who produce gasoline by adding blendstocks to
PCG to report the sulfur, benzene and RVP results
o Blending manufacturers who comply by subtraction, follow the requirements in
1090.905(c)(3) to account for and report the addition of downstream oxygenate.
o Blending manufacturers who comply by addition must include the sulfur and benzene
content of the blendstock in their compliance calculations following the requirements in
1090.905(c)(4).
Special instructions for gasoline produced by adding blendstocks to transmix gasoline product
(TGP):
o Blendstocks added to TGP – Report using either the compliance by addition or
compliance by subtraction method and treat the transmix gasoline product as PCG
o Both blendstocks and PCG added to TGP – Report using either the compliance by
addition or compliance by subtraction method. If using compliance by subtraction, report
the volume and properties of the PCG batch as one batch and the volume and properties
of the TGP batch as a second batch.
o If complying by addition, use the volume type (“DBS”) for the blendstock and report the
volume type (“OTH”) and the final designation (e.g. RFG, CG) as the product type for
the final certified batch.
 For the final certified batch, report 1) the RVP of RBOB and RFG that is
designated as “Intended for Oxygenate Blending” under §1090.1010(a)(4) using
hand-blend. Report RVP of CG and CBOB using neat gasoline, and 2) the
measured sulfur content of the finished batch prior to a hand blend in field 19.
o TGP only or TGP plus PCG – Report as one overall batch using the properties of the final
certified batch. Report the volume type (“OTH”) and the final designation (e.g. RFG,
CG) as the product type.
o





Reporting deadlines


Entities shall report on all batches produced or imported by March 31st each year for the prior
calendar year averaging period.
Field Instructions
Field Field Name
Units
Field Formats, Codes & Special Instructions
No.
1
Report Form ID
AAAAAA; Character.
Enter STR0200
2
Report Type
A; Character. Specify if the data submitted in this
report is original or if it is being resubmitted. Submit
only one original report; any corrections or updates
should be marked as a resubmission.
O = Original
R = Resubmission
3
CBI
A; Character. Specify if the data contained within the
report is claimed as Confidential Business Information
(CBI) under 40 CFR Part 2, subpart B:
Y = Confidential Business Information
N = Non-Confidential Business Information
EPA Form 5900-476

Page 2 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
4
5

Field Name
Report Date

6

Averaging/Compliance
Period
Reporter ID

7

Company ID

8

Facility ID

9

Batch Number

EPA Form 5900-476

Units

Field Formats, Codes & Special Instructions
MM/DD/YYYY; Character. Enter the date the original
or resubmitted report is created.
YYYY; Character. Enter the averaging/compliance
year the report covers.
AAAA; Character. Enter the EPA-assigned fourcharacter ID of the submitter. This may be the
company itself or a third party, such as an independent
lab.
AAAA; Character. Enter the EPA assigned fourcharacter ID for the refiner or importer that produced
or imported the batch of gasoline.
AAAAA; Character. Enter EPA-assigned fivecharacter ID for the facility reporting ID. Include
leading zeros as needed.
AAAAAA; Character. The batch number assigned by
the Refiner/Importer identifying the gasoline batch this
report describes. This six digit batch number must form
a unique identifier for a given volume when combined
with company ID, facility and averaging/compliance
period (e.g., 4321-54321-2014-000001, 4321-543212014-000002, etc.), as described in 40 CFR 1090.1020.
Please include leading zeros where applicable.

Page 3 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
10

Field Name
Volume Type

Units

Field Formats, Codes & Special Instructions
AAA; Character. Enter the one appropriate volume
type code from the following list. For additional
information on compliance calculations, see 40 CFR
part 1090, subpart H.
Volumes reported with positive values and
included in compliance calculations
DOM = Any domestically produced batch
volume
IMP = Any imported product included in
compliance calculations
DBS = Any blendstock blended with PCG or
TGP when complying by addition
Volumes reported with negative values and
included in compliance calculations
PCG = Previously certified gasoline or TGP
when complying by subtraction
REC = Recertification of the BOB with less
oxygenate
EXP = Exported Batch; where a portion of a
previously certified batch has been exported
under 40 CFR 1090.645.
Volumes reported as positive values but not
included in compliance calculations
TOR = Truck or rail imports not included in
compliance calculations
OTH = Gasoline produced with PCG and/or
TGP by addition, certified butane blendstocks,
certified pentane blendstocks, oxygenate
producer batches or GTAB that are only used
for per gallon compliance demonstration (see
1090.700(e))
Volumes not included in compliance
calculations
ZER = Cancelled batch – zero volume (such as
when an entire previously certified batch has
been contaminated, reprocessed, or exported).
Provide additional explanation in the
comments field.

EPA Form 5900-476

Page 4 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
11

Field Name

Units

Field Formats, Codes & Special Instructions

Batch Volume

Gallons

+ 999999999; Number. Production volume of the
reported batch.
Positive batch volumes include volume types
of DOM, IMP, DBS, TOR, OTH
Negative batch volumes include volume types
EXP, REC, PCG
Zero batch volume include volume types of
ZER
For any BOB- the volume is the sum of the BOB
volume and the oxygenate volume that the gasoline
manufacturer specifies to be blended with the BOB.
Intended for Oxygenate Blending - For gasoline that is
not a BOB but designated as intended for oxygenate
blending (using product type codes “RU” or “CU”), do
not include the oxygenate volume that the gasoline
manufacturer specifies to be blended with the gasoline
under 1090.1010(a)(4).

12

Production Date

If reporting a zero batch volume other than a canceled
batch, please provide additional detail in comments
field
MM/DD/YYYY; Character. Date the reported batch
was produced or imported.
For Gasoline manufacturers that recertify BOB to
gasoline only – Enter the date the batch was recertified.

EPA Form 5900-476

Page 5 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
13

Field Name
Date PCG, Butane, or
Pentane Batch
Received

Units

Field Formats, Codes & Special Instructions
MM/DD/YYYY; Character. Enter date received for
PCG, Butane, or Pentane. Date received for PCG
product only required when using compliance by
subtraction method. If blending PCG with certified
butane or certified pentane products, record the date the
butane or pentane product was received.
-PCG received from another company or site Enter the date the batch was received.
-PCG originating on-site - enter the date the
PCG was designated to be used to produce a
new batch of gasoline.
-Butane Blendstock – Date butane blendstock
received
-Pentane Blendstock – Date pentane
blendstock received
-Other Product Type - If the volume type is not
PCG, butane, or pentane, enter “NA”.

EPA Form 5900-476

Page 6 of 11

OMB Control No. ####-####
Expires: ##/##/####

14

Product Type

AA; Character. Enter the one appropriate product
description code from the following list.
Reformulated gasoline:
RG = Reformulated Gas
RD = RBOB including oxygenate
RU = Gasoline that is not a RBOB but
designated as intended for oxygenate blending
RP = Blendstock added to PCG or TGP when
complying by addition
BC = certified butane blended with PCG
RFG/RBOB
PC = certified pentane blended with PCG
RFG/RBOB
Conventional gasoline:
CG = Conventional Gasoline
CD = Conventional Gasoline Blendstock for
Oxygenate Blending (CBOB) including
oxygenate
CU = Gasoline that is not a CBOB but
designated as intended for oxygenate blending
CP = Blendstock added to PCG or TGP when
complying by addition
BX = certified butane blended with PCG
CG/CBOB
PX = certified pentane blended with PCG
CG/CBOB
Oxygenate producer batches:
DE – Denatured ethanol using certified ethanol
denaturant
DU – Denatured ethanol from non-certified
denaturant
DO – Oxygenate other than ethanol (enter
oxygenate type in comments field)
Other products:
DL = Product designated as ULSD that
exceeds the sulfur 15ppm standard
GT = Gasoline Treated as Blendstock (GTAB)
TP – Transmix gasoline product treated as
PCG that is used when complying by
subtraction
PP = Certified pentane reported by certified
pentane producer
BU = Certified butane batch reported by
certified butane blender
PU = Certified pentane batch reported by
certified pentane blender

EPA Form 5900-476

Page 7 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
15

Field Name

Units

Field Formats, Codes & Special Instructions
When using RD or CD product type codes, enter into
oxygenate field the intended oxygenate
AA; Character. Identify the designation under the
gasoline volatility standards found at 1090.215.

Gasoline Volatility
Standards

Summer Gasoline
V1 = Federal 7.8 psi standard
V2 = Federal 9.0 psi standard
V4 = Federal SIP
V5 = Federal 7.4 psi standard
EX = Exempt from RVP control
Winter Gasoline
VN = Not VOC Controlled
For “EX” batches, identify areas where fuel is intended
for use in the comment field.
16

Oxygenate

17

Oxygenate Parameter
Test Method

volume %

Use “NA” if this field is not applicable
99.99; Number. Enter the percentage of oxygenate in
the handblend created under 1090.1340 or the
measured amount of oxygenate. Use “NA” if this field
is not applicable; use “ND” if “not detected” by the
reported test method. Note only enter a zero if testing
resulted in 0 value.
AAAAA; Character. Identify test method used to
measure parameter for each oxygenate.
Handblend – Enter “handblend” for BOB
batches under 1090.1340
ASTM Test methods – Provide the ASTM
Method number (e.g., D5191)
PBMS - provide the descriptive title name.
Supplier Provided – If tested by supplier and
testing method is unavailable, state “supplier
tested”
Use “NA” if this field is not applicable

EPA Form 5900-476

Page 8 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
18

Field Name

Units

Oxygenate Type

Field Formats, Codes & Special Instructions
AAAAA; Character. Identify each type of oxygenate
used by providing one of the codes below. For batches
with BOB product types, enter the oxygenate type used
in creating the handblend.
ETOH – denatured fuel ethanol
MTBE – methyl tertiary butyl ether (MTBE)
ETBE – ethyl tertiary butyl ether (ETBE)
ISOB - isobutanol
TAME – tertiary amyl methyl ether (TAME)
MTHL – methanol
TBUT – tert-butanol
UNKN – Unknown
OTHR – Other
Batches containing two or more oxygenates – Enter the
primary oxygenate value in field 18 followed by
entering the additional oxygenates and percent values
in the “comments” field. Do not include “not detected”
or ND values in 1090.1355(e)

19

Sulfur – Per gallon
compliance value

ppm

20

Sulfur – Average
compliance value

ppm

21

Sulfur Parameter Test
Method

If “Other”, enter the name of the oxygenate in the
“Comments” field. Use “NA” if this field is not
applicable
999; Number. Enter the measured or presumed value
under 1090.1710(g) as appropriate. Use “NA” if this
field is not applicable. Note only enter a zero if testing
resulted in 0 value on a test method that is validated
down to zero.
999; Number. Enter result for hand blend or finished
gasoline or blendstock for PCG complying by addition.
Enter the measured or presumed value as appropriate.
Use “NA” if this field is not applicable. Note only
enter a zero if testing resulted in 0 value on a test
method that is validated down to zero.
AAAAA; Character. Identify test method(s) used to
measure parameter.
ASTM Test methods – Provide the ASTM
Method number (e.g., D5191)
PBMS - provide the descriptive title name.
Default value provided in part 1090 - state
“Default” under 1090.740
Presumed value provided in part 1090 –
state “presumed” under 1090.1710(g)
Use “NA” if this field is not applicable

EPA Form 5900-476

Page 9 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
22

23

Field Name

Units

Field Formats, Codes & Special Instructions

Benzene

volume %

9.99; Number. Enter the measured or presumed value
under 1090.1710(g) as appropriate. Use “NA” if this
field is not applicable. Note only enter a zero if testing
resulted in 0 value on a test method that is validated
down to zero.
AAAAA; Character. Identify test method used to
measure parameter.

Benzene Parameter
Test Method

24

RVP

25

RVP Parameter Test
Method

psi

ASTM Test methods – Provide the ASTM
Method number (e.g., D5191)
PBMS - provide the descriptive title name.
Default value provided in part 1090 - state
“Default” under 1090.740
Presumed value provided in part 1090 –
state “presumed” under 1090.1710(g)
Use “NA” if this field is not applicable
99.99; Number.
Enter the measured or presumed value under
1090.1710(g) as appropriate. Use “NA” if this field is
not applicable.
AAAAA; Character. Identify test method(s) used to
measure parameter.
ASTM Test methods – Provide the ASTM
Method number (e.g., D5191)
PBMS - provide the descriptive title name.

26

Benzene deficit

27

Sulfur deficit

28

Butane or Pentane

EPA Form 5900-476

volume %

Presumed value provided in part 1090 –
state “presumed” under 1090.1710(g)
Use “NA” if this field is not applicable
999999; Number. Gasoline manufacturers who
recertify a BOB with less oxygenate calculate the
benzene deficit for the batch using 1090.740(b)(2). Use
“NA” if this field is not applicable
999999; Number. Gasoline manufacturers who
recertify a BOB with less oxygenate calculate the
sulfur deficit for the batch using 1090.740(b)(1).
Use “NA” if this field is not applicable
999.99; Number. The volume percentage of butane in
certified butane batches or pentane in certified pentane
batches for blending. Enter the measured value. Use
“NA” if this field is not applicable.

Page 10 of 11

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
29

Field Name

Units

Butane or Pentane
Parameter Test
Method

Field Formats, Codes & Special Instructions
AAAAA; Character. Identify test method used to
measure parameter.
ASTM Test methods – Provide the ASTM
Method number (e.g., D5191)
PBMS - provide the descriptive title name.

30

Comments

N/A

Use “NA” if this field is not applicable
AAAAA – Enter any additional information or
recordkeeping specific to this batch as needed. When
providing additional information on a specific field,
begin the comment with the field number in
parentheses followed by the additional information.
Butane blenders and pentane producers – Enter
statement here affirming that the reported batch meets
or does not meet all applicable standards in subpart C
of part 1090.

Paperwork Reduction Act Statement
This collection of information is approved by OMB under the Paperwork Reduction Act, 44 U.S.C. 3501
et seq. (OMB Control No. 2060-XXXX). Responses to this collection of information are mandatory (40
CFR part 1090). An agency may not conduct or sponsor, and a person is not required to respond to, a
collection of information unless it displays a currently valid OMB control number. The public reporting
and recordkeeping burden for this collection of information is estimated to range from one to two hours s
per response. Send comments on the Agency’s need for this information, the accuracy of the provided
burden estimates and any suggested methods for minimizing respondent burden to the Regulatory Support
Division Director, U.S. Environmental Protection Agency (2821T), 1200 Pennsylvania Ave., NW,
Washington, D.C. 20460. Include the OMB control number in any correspondence. Do not send the
completed form to this address.

EPA Form 5900-476

Page 11 of 11


File Typeapplication/pdf
File TitleMicrosoft Word - fuels_batch_annual_report.docx
Authorblarson
File Modified2020-12-03
File Created2020-12-03