5900-477 Instructions for STR0500: Independent Surveyor Annual Re

Fuels Regulatory Streamlining (Final Rule)

fuels_independent_survey_annual_report

OMB: 2060-0731

Document [pdf]
Download: pdf | pdf
OMB Control No. ####-####
Expires: ##/##/####

Instructions for STR0500: Independent Surveyor Annual Reporting for Fuels
Who must report
Any independent surveyor must report on test results for gasoline and diesel during the averaging period.

Reporting requirements
•
•

40 CFR 1090 subpart J provides key requirements and reporting information (available at [link to
ECFR.gov]).
Annual reports must include the requirements described in 40 CFR 1090.925(c). These
requirements include:
o Identification of the parties that participated in the survey
▪ Company name
▪ EPA assigned registration number
▪ Year of participation
o Provide a summary report for each geographic area (strata) type as well as a nationally
▪ Densely Populated Area
▪ Transportation Corridor
▪ Rural area
▪ Rural
▪ National
▪
o Summary statistics for each identified geographic area type as well as nationally
▪ Number of samples collected and tested
▪ Mean for each gasoline/diesel parameter
▪ Median for each gasoline/diesel parameter
▪ Range for each gasoline/diesel parameter
▪ Standard deviation for each measured gasoline/diesel parameter
▪ Each summary statistic to be expressed in appropriate units
o The estimated compliance rate for each measured gasoline and diesel parameter
▪ Sulfur Standards
• Gasoline sulfur – number of results above 95 ppm
• ULSD diesel sulfur – number of results above 15 ppm
▪ RVP Standards
• Federal 9.0 psi maximum RVP – number of results above 9.0 psi for any
gasoline designated as summer gasoline or located at any location in the
United States during the summer season
• Federal 7.8 psi maximum RVP – number of results above 7.8 psi for any
gasoline designated as 7.8 psi summer gasoline or located in any of the
areas described in §1090.215.
• RFG maximum RVP per-gallon standard – number of results above 7.4
psi for any gasoline designated as Summer RFG or located in RFG areas
specified in §1090.270.
▪ Cetane index
• ULSD diesel – number of results with cetane index less than 40

EPA Form 5900-477

Page 1 of 14

OMB Control No. ####-####
Expires: ##/##/####

▪

Aromatic index
• ULSD diesel – number of results with aromatic content greater than 35
volume percent

Reporting deadlines
•

Independent surveyors must submit annual reports by March 31 for the preceding compliance
year

How to submit reports
• All reporting, including on all of the elements described above, must be submitted electronically,
using forms and procedures specified by EPA.
•

EPA maintains report templates, electronic submission procedures and additional support options
at https://www.epa.gov/fuels-registration-reporting-and-compliance-help/reporting-fuelprograms.

EPA Form 5900-477

Page 2 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field Instructions
Field Field Name
No.
1
Report Form ID
2

Report Type

3

CBI

4

Report Date

5

Compliance Period

6

Reporter ID

7

Geographic Area

8

Fuel Type

9

Samples Collected and
Tested

10

Sulfur Compliance

EPA Form 5900-477

Units

Field Formats, Codes & Special Instructions
AAAAAA; Character.
Enter STR0500
A; Character. Specify if the data submitted in this report
is original or if it is being resubmitted. Submit only one
original report; any corrections or updates should be
marked as a resubmission.
O = Original
R = Resubmission
A; Character. Specify if the data contained within the
report is claimed as Confidential Business Information
(CBI) under 40 CFR Part 2, subpart B:
Y = Confidential Business Information
N = Non-Confidential Business Information
MM/DD/YYYY; Character. Enter the date the original
or resubmitted report is created.
YYYY; Character. Enter the participation year the report
covers.
AAAA; Character. Enter the EPA-assigned fourcharacter ID of the independent surveyor submitting the
report.
AAA; Character. Enter the geographic area (strata) code
associated with this sample location per the approved
sample plan.
DPA – Densely Populated Area
TCR – Transportation Corridor
RRL – Rural Area
NAT – National
AAAAA; Character. Enter the strata code for this
summary report.
DPA – Densely populated areas
TCR – Transportation corridors
RRL – Rural areas
NAT – National
AAAAAA; Character. Enter the code representing the
fuel type reported
GAS – Gasoline
DSL – Diesel fuel
9,999; Number. Enter the number of samples collected
and tested in the geographic area during the participation
year.
9,999; Number. Enter the number of results above the
applicable fuel type sulfur standard:
95 ppm for gasoline
15 ppm for diesel

Page 3 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
11

Field Name

Units

12

RVP 7.8 Compliance

13

RVP RFG Max

14

Sulfur Mean

ppm

15

Sulfur Median

ppm

16

Sulfur Range

ppm

17

Sulfur Std. Deviation

ppm

18

Oxy ETOH Mean

volume %

19

Oxy ETOH Median

volume %

RVP 9.0 Compliance

EPA Form 5900-477

Field Formats, Codes & Special Instructions
9,999; Number. Enter the number of results above 9.0 psi
for any gasoline designated as summer gasoline or
located at any location in the US during summer season.
Use “NA” if this field is not applicable.
9,999; Number. Enter the number of results above 7.8 psi
for any gasoline designated as 7.8 psi summer gasoline or
located in any of the areas described in 1090.215.
Use “NA” if this field is not applicable.
9,999; Number. Enter the number of results above 7.4 psi
for any gasoline designated as summer RFG or located in
RFG areas specified in 1090.270.
Use “NA” if this field is not applicable.
9999; Number. Calculate and enter the mean value of
sulfur for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
9999; Number. Calculate and enter the median value of
sulfur for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
9999 to 9999; Character. Enter the minimum and
maximum sulfur values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8 to 15”
9999; Number. Calculate and enter the standard
deviation of sulfur for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the mean value of
ethanol for the compliance period. Use “NA” if this field
is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99; Number. Calculate and enter the median value of
ethanol for the compliance period. Use “NA” if this field
is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.

Page 4 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
20

Field Name

Units

Field Formats, Codes & Special Instructions

Oxy ETOH Range

volume %

21

Oxy ETOH Std.
Deviation

volume %

22

Oxy MTBE Mean

volume %

23

Oxy MTBE Median

volume %

24

Oxy MTBE Range

volume %

25

Oxy MTBE Std.
Deviation

volume %

26

Oxy ETBE Mean

volume %

27

Oxy ETBE Median

volume %

999.99 to 999.99; Character. Enter the minimum and
maximum ethanol values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of ethanol for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the mean value of
MTBE (methyl tert-butyl ether) for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the median value of
MTBE (methyl tert-butyl ether) for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99 to 999.99; Character. Enter the minimum and
maximum MTBE (methyl tert-butyl ether) values as a
range for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of MTBE (methyl tert-butyl ether) for the
compliance period. Use “NA” if this field is not
applicable (e.g. for diesel samples); use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the mean value of
ETBE (ethyl tert-butyl ether) for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the median value of
ETBE (ethyl tert-butyl ether) for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.

EPA Form 5900-477

Page 5 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
28

Field Name

Units

Field Formats, Codes & Special Instructions

Oxy ETBE Range

volume %

29

Oxy ETBE Std.
Deviation

volume %

30

Oxy ISOB Mean

volume %

31

Oxy ISOB Median

volume %

32

Oxy ISOB Range

volume %

33

Oxy ISOB Std.
Deviation

volume %

34

Oxy TAME Mean

volume %

35

Oxy TAME Median

volume %

999.99 to 999.99; Character. Enter the minimum and
maximum ETBE (ethyl tert-butyl ether) values as a range
for the compliance period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of ETBE (ethyl tert-butyl ether) for the
compliance period. Use “NA” if this field is not
applicable (e.g. for diesel samples); use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the mean value of
sulfur for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the median value of
Isobutanol for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99 to 999.99; Character. Enter the minimum and
maximum Isobutanol values as a range for the
compliance period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of Isobutanol for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the mean value of
Isobutanol for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99; Number. Calculate and enter the median value of
TAME (tert-Amyl methyl ether) for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.

EPA Form 5900-477

Page 6 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
36

Field Name

Units

Field Formats, Codes & Special Instructions

Oxy TAME Range

volume %

37

Oxy TAME Std.
Deviation

volume %

38

Oxy MTHL Mean

volume %

39

Oxy MTHL Median

volume %

40

Oxy MTHL Range

volume %

41

Oxy MTHL Std.
Deviation

volume %

42

Oxy TBUT Mean

volume %

43

Oxy TBUT Median

volume %

999.99 to 999.99; Character. Enter the minimum and
maximum TAME (tert-Amyl methyl ether) values as a
range for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of TAME (tert-Amyl methyl ether) for the
compliance period. Use “NA” if this field is not
applicable (e.g. for diesel samples); use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the mean value of
methanol for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99; Number. Calculate and enter the median value of
methanol for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99 to 999.99; Character. Enter the minimum and
maximum methanol values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of methanol for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the mean value of
tert-Butanol for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99; Number. Calculate and enter the median value of
tert-Butanol for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.

EPA Form 5900-477

Page 7 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
44

Field Name

Units

Field Formats, Codes & Special Instructions

Oxy TBUT Range

volume %

45

Oxy TBUT Std.
Deviation

volume %

46

Oxy UNKN Mean

volume %

47

Oxy UNKN Median

volume %

48

Oxy UNKN Range

volume %

49

Oxy UNKN Std.
Deviation

volume %

50

Oxy OTHR Mean

volume %

51

Oxy OTHR Median

volume %

999.99 to 999,99; Character. Enter the minimum and
maximum tert-Butanol values as a range for the
compliance period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of tert-Butanol for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the mean value of
unknown oxygenate for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the median value of
unknown oxygenate for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99 to 999.99; Character. Enter the minimum and
maximum unknown oxygenate values as a range for the
compliance period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of unknown oxygenate for the compliance
period. Use “NA” if this field is not applicable (e.g. for
diesel samples); use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99; Number. Calculate and enter the mean value of
other oxygenate for the compliance period. Use “NA” if
this field is not applicable; use “ND” if “not detected” by
the reported test method.  Note entering a zero
implies testing resulted in 0 value.
999.99; Number. Calculate and enter the median value of
other oxygenate for the compliance period. Use “NA” if
this field is not applicable; use “ND” if “not detected” by
the reported test method.  Note entering a zero
implies testing resulted in 0 value.

EPA Form 5900-477

Page 8 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
52

Field Name

Units

Field Formats, Codes & Special Instructions

Oxy OTHR Range

volume %

53

Oxy OTHR Std.
Deviation

volume %

54

Benzene Mean

volume %

55

Benzene Median

volume %

56

Benzene Range

volume %

57

Benzene Std. Deviation volume %

58

RVP Mean

Psi

59

RVP Median

Psi

999.99 to 999.99; Character. Enter the minimum and
maximum other oxygenate values as a range for the
compliance period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of other oxygenate for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the mean value of
benzene for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99; Number. Calculate and enter the median value of
benzene for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.99 to 999.99; Character. Enter the minimum and
maximum benzene values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of benzene for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.99; Number. Calculate and enter the mean value of
RVP (Reid vapor pressure) for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the median value of
RVP (Reid vapor pressure) for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.

EPA Form 5900-477

Page 9 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
60

Field Name

Units

Field Formats, Codes & Special Instructions

RVP Range

Psi

61

RVP Std. Deviation

Psi

62

API Spec. Gravity Mean ᵒ API

63

API Spec. Gravity
Median

ᵒ API

64

API Spec. Gravity
Range

ᵒ API

65

API Spec. Gravity Std.
Deviation

ᵒ API

66

Aromatics Mean

volume %

67

Aromatics Median

volume %

999.99 to 999.99; Character. Enter the minimum and
maximum RVP (Reid vapor pressure) values as a range
for the compliance period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of RVP (Reid vapor pressure) for the
compliance period. Use “NA” if this field is not
applicable (e.g. for diesel samples); use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the mean value of
API specific gravity for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99; Number. Calculate and enter the median value of
API specific gravity for the compliance period.
Use “NA” if this field is not applicable; use “ND” if “not
detected” by the reported test method.  Note entering a
zero implies testing resulted in 0 value.
999.99 to 999.99; Character. Enter the minimum and
maximum API specific gravity values as a range for the
compliance period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.01 to 15.12”
999.99; Number. Calculate and enter the standard
deviation of API specific gravity for the compliance
period. Use “NA” if this field is not applicable (e.g. for
diesel samples); use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.9; Number. Calculate and enter the mean value of
aromatics for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.9; Number. Calculate and enter the median value of
aromatics for the compliance period. Use “NA” if this
field is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.

EPA Form 5900-477

Page 10 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
68

Field Name

Units

Field Formats, Codes & Special Instructions

Aromatics Range

volume %

69

Aromatics Std.
Deviation

volume %

70

Olefins Mean

volume %

71

Olefins Median

volume %

72

Olefins Range

volume %

73

Olefins Std. Deviation

volume %

74

E200 Mean

volume %

75

E200 Median

volume %

999.9 to 999.9; Character. Enter the minimum and
maximum aromatics values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.0 to 15.1”
999.9; Number. Calculate and enter the standard
deviation of aromatics for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the mean value of
olefins for the compliance period. Use “NA” if this field
is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.9; Number. Calculate and enter the median value of
olefins for the compliance period. Use “NA” if this field
is not applicable; use “ND” if “not detected” by the
reported test method.  Note entering a zero implies testing
resulted in 0 value.
999.9 to 999.9; Character. Enter the minimum and
maximum olefins values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.0 to 15.1”
999.9; Number. Calculate and enter the standard
deviation of olefins for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the mean value of
E200 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the median value of
E200 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.

EPA Form 5900-477

Page 11 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
75

Field Name

Units

Field Formats, Codes & Special Instructions

E200 Range

volume %

77

E200 Std. Deviation

volume %

78

E300 Mean

volume %

79

E300 Median

volume %

80

E300 Range

volume %

81

E300 Std. Deviation

volume %

82

T50 Mean

℉

83

T50 Median

℉

999.9 to 999.9; Character. Enter the minimum and
maximum E200 values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.0 to 15.1”
999.9; Number. Calculate and enter the standard
deviation of E200 for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the mean value of
E300 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the median value of
E300 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
999..9 to 999.9; Character. Enter the minimum and
maximum E300 values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.0 to 15.1”
999.9; Number. Calculate and enter the standard
deviation of E300 for the compliance period.
Use “NA” if this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the mean value of
T50 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the median value of
T50 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.

EPA Form 5900-477

Page 12 of 14

OMB Control No. ####-####
Expires: ##/##/####

Field
No.
84

Field Name

Units

Field Formats, Codes & Special Instructions

T50 Range

℉

85

T50 Std. Deviation

℉

86

T90 Mean

℉

87

T90 Median

℉

88

T90 Range

℉

89

T90 Std. Deviation

℉

90

Comments

N/A

999.9 to 999.9; Character. Enter the minimum and
maximum T50 values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.0 to 15.1”
999.9; Number. Calculate and enter the standard
deviation of T50 for the compliance period. Use “NA” if
this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the mean value of
T90 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
999.9; Number. Calculate and enter the median value of
T90 for the compliance period. Use “NA” if this field is
not applicable; use “ND” if “not detected” by the reported
test method.  Note entering a zero implies testing resulted
in 0 value.
999.9 to 999.9; Character. Enter the minimum and
maximum T90 values as a range for the compliance
period. Use “NA” if this field is not
applicable; use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
For example, “8.0 to 15.1”
999.9; Number. Calculate and enter the standard
deviation of T90 for the compliance period. Use “NA” if
this field is not applicable (e.g. for diesel
samples); use “ND” if “not detected” by the reported test
method.  Note entering a zero implies testing resulted
in 0 value.
AAAAA – Text. Enter any additional information or
recordkeeping specific to this sample as needed.

Paperwork Reduction Act Statement
This collection of information is approved by OMB under the Paperwork Reduction Act, 44 U.S.C. 3501
et seq. (OMB Control No. 2060-XXXX). Responses to this collection of information are mandatory (40
CFR part 1090). An agency may not conduct or sponsor, and a person is not required to respond to, a
collection of information unless it displays a currently valid OMB control number. The public reporting
and recordkeeping burden for this collection of information is estimated to range from five to 10 hours
per response. Send comments on the Agency’s need for this information, the accuracy of the provided
burden estimates and any suggested methods for minimizing respondent burden to the Regulatory Support

EPA Form 5900-477

Page 13 of 14

OMB Control No. ####-####
Expires: ##/##/####

Division Director, U.S. Environmental Protection Agency (2821T), 1200 Pennsylvania Ave., NW,
Washington, D.C. 20460. Include the OMB control number in any correspondence. Do not send the
completed form to this address.

EPA Form 5900-477

Page 14 of 14


File Typeapplication/pdf
File Modified2020-10-16
File Created2020-10-16

© 2024 OMB.report | Privacy Policy