PBMS0009 Spreadsheet Example VCSB 10 ppm Sulfur in Butane Pre

Fuels Regulatory Streamlining (Non-Substantive Change)

Copy of Copy of draft vcsb-sulfur-butane-test-method-sprdsht-example-5-10-2022.xlsx

Fuels Regulatory Streamlining

OMB: 2060-0731

Document [xlsx]
Download: xlsx | pdf

Overview

10 ppm S Precision
10 ppm S Accuracy
EX - 10 ppm S Precision
EX - 10 ppm S Accuracy


Sheet 1: 10 ppm S Precision

Spreadsheet Example VCSB 10 ppm Sulfur in Butane Precision Demonstration [PBMS0009:OMB #2060-0731, Expires 1/31/2024]. This collection of information is approved by OMB under the Paperwork Reduction Act, 44 U.S.C. 3501 et seq. OMB Control No 2060-0731. Responses to this collection of information are voluntary 1090 CFR 1360 through 1090 1365. An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB control number. The public reporting and recordkeeping burden for this collection of information is estimated to average 180 hours per response. Send comments on the Agency’s need for this information, the accuracy of the provided burden estimates and any suggested methods for minimizing respondent burden to the Regulatory Support Division Director, U.S. Environmental Protection Agency (2821T), 1200 Pennsylvania Ave., NW, Washington, D.C. 20460. Include the OMB control number in any correspondence. Do not send the completed form to this address.
Test Method
Name of Method:
Laboratory Identification
Laboratory Name:
Laboratory Street Address:
Laboratory City:
Laboratory State:
Laboratory Zip code:
Laboratory Contact Person:
Laboratory Contact Phone Number
Laboratory Contact Facsimile Number
Laboratory Contact E-mail Address
10 ppm Sulfur Precision Criterion - The maximum allowable standard deviation computed from results of a minimum of 20 tests made over 20 days on samples using good laboratory practices taken from a single homogenous commercially available gasoline must be less than or equal to 1.5 times the repeatability (r) divided by 2.77, where "r" equalts the ASTM repeatability of ASTM D6667-16(Reapproved 2019). Example: A 10ppm sulfur in butane sample: maximum allowable standard deviation of 20 tests less than or equal 1.5*(1.152 ppm/2.77)=0.62383 ppm. You may make up to 4 separate measurements in a 24-hour period, as long as the interval between measurements is at least 4 hours.
Is 10 ppm Sulfur in Butane Precision Criterion Met? REQUIRED DATA MISSING
standard deviation REQUIRED DATA MISSING
Laboratory Test Identification Number Date Time Test Result (ppm) Data Entry QC Check on Test Result




DATA REQUIRED IN CELL D18




DATA REQUIRED IN CELL D19




DATA REQUIRED IN CELL D20




DATA REQUIRED IN CELL D21




DATA REQUIRED IN CELL D22




DATA REQUIRED IN CELL D23




DATA REQUIRED IN CELL D24




DATA REQUIRED IN CELL D25




DATA REQUIRED IN CELL D26




DATA REQUIRED IN CELL D27




DATA REQUIRED IN CELL D28




DATA REQUIRED IN CELL D29




DATA REQUIRED IN CELL D30




DATA REQUIRED IN CELL D31




DATA REQUIRED IN CELL D32




DATA REQUIRED IN CELL D33




DATA REQUIRED IN CELL D34




DATA REQUIRED IN CELL D35




DATA REQUIRED IN CELL D36




DATA REQUIRED IN CELL D37

Sheet 2: 10 ppm S Accuracy

Spreadsheet Example VCSB 10 ppm Sulfur in Butane Accuracy Demonstration [PBMS0009:OMB #2060-0731, EPA ICR number 2607.02: Expires 1/31/2024]







Test Method
Name of Method: 0
Laboratory Identification
Laboratory Name: 0
Laboratory Street Address: 0
Laboratory City: 0
Laboratory State: 0
Laboratory Zip code: 0
Laboratory Contact Person: 0
Laboratory Contact Phone Number 0
Laboratory Contact Facsimile Number 0
Laboratory Contact E-mail Address 0
1 to 10 ppm Accuracy Criterion - the arithmetic average of a continuous series of at least 10 tests performed on a commercially available gravimetric sulfur standard in the range of 1 to 10 ppm sulfur, say 10 ppm, shall not differ from the accepted reference value (ARV) of that standard by more than 0.4678725 ppm, where maximum absolute difference = 0.75*(1.5*(1.152 ppm/2.77)). Individual test results shall be compensated for any known chemical interferences.



Accuracy Criterion for 1-10 ppm




gravimetric sulfur standard




Is 1-10 ppm Sulfur Accuracy Criterion Met? REQUIRED DATA MISSING




Arithmetic Average (ppm) REQUIRED DATA MISSING




Vendor Name of Gravimetric Standard





Lot Identification Number of Gravimetric Standard
Concentration QC Check on ARV



Accepted Reference Value (ARV) of Gravimetric Standard (ppm)
ARV TOO LOW IN CONCENTRATION



Difference between Arithmetic Average and ARV of Gravimetric Standard REQUIRED DATA MISSING




Laboratory Test Identification Number Date Time Test Result (ppm) Data Entry QC Check on Test Result







DATA REQUIRED IN CELL D26







DATA REQUIRED IN CELL D27







DATA REQUIRED IN CELL D28







DATA REQUIRED IN CELL D29







DATA REQUIRED IN CELL D30







DATA REQUIRED IN CELL D31







DATA REQUIRED IN CELL D32







DATA REQUIRED IN CELL D33







DATA REQUIRED IN CELL D34







DATA REQUIRED IN CELL D35




Sheet 3: EX - 10 ppm S Precision

Spreadsheet Example VCSB 10 ppm Sulfur in Butane Precision Demonstration [PBMS0009: OMB #2060-0731, EPA ICR number 2607.02: Expires 1/31/2024]
Test Method
Name of Method: Total Sulfur in Liquid Aromatic Hydrocarbons and Their Derivatives by XRF
Laboratory Identification
Laboratory Name: USEPA National and Vehicle Fuels Emissions Laboratory/OAR
Laboratory Street Address: 2565 Plymouth Road, Mailcode AATSG
Laboratory City: Ann Arbor
Laboratory State: Michigan
Laboratory Zip code: 48105
Laboratory Contact Person: John Doe
Laboratory Contact Phone Number xxx-xxx-xxxx
Laboratory Contact Facsimile Number xxx-xxx-xxxx
Laboratory Contact E-mail Address [email protected]
10 ppm Sulfur Precision Criterion - The maximum allowable standard deviation computed from results of a minimum of 20 tests made over 20 days (7 or fewer tests per week and 2 or fewer tests per day) on samples using good laboratory practices taken from a single homogenous commercially available gasoline must be less than or equal to 1.5 times the repeatability (r) divided by 2.77, where "r" equalts the ASTM repeatability of ASTM D6667-16(Reapproved 2019). Example: A 10ppm sulfur in butane sample: maximum allowable standard deviation of 20 tests less than or equal 1.5*(1.15 ppm/2.77)=0.62383 ppm. You may make up to 4 separate measurements in a 24-hour period, as long as the interval between measurements is at least 4 hours.
Is 10 ppm Sulfur Precision Criterion Met? PASSED
standard deviation 0.04
Laboratory Test Identification Number Date Time Test Result (ppm) Data Entry QC Check on Test Result
######### 3/26/2021 8:00 AM 6.003 OK
######### 3/29/2021 8:05 AM 6.021 OK
######### 3/30/2021 8:03 AM 6.043 OK
######### 3/31/2021 8:05 AM 5.993 OK
######### 4/1/2021 8:05 AM 6.003 OK
######### 4/2/2021 8:03 AM 6.092 OK
######### 4/3/2021 8:03 AM 6.101 OK
######### 4/4/2021 8:03 AM 6.045 OK
######### 4/5/2021 8:00 AM 6.003 OK
######### 4/8/2021 8:00 AM 6.021 OK
######### 4/9/2021 8:02 AM 5.989 OK
######### 4/10/2021 8:00 AM 5.962 OK
######### 4/11/2021 8:00 AM 6.010 OK
######### 4/12/2021 8:00 AM 6.032 OK
######### 4/15/2021 8:15 AM 6.053 OK
######### 4/16/2021 8:00 AM 6.050 OK
######### 4/17/2021 8:07 AM 5.989 OK
######### 4/18/2021 8:00 AM 6.033 OK
######### 4/19/2021 8:00 AM 5.939 OK
######### 4/22/2021 8:20 AM 6.042 OK

Sheet 4: EX - 10 ppm S Accuracy

Spreadsheet Example VCSB 10 ppm Sulfur in Butane Accuracy Demonstration [PBMS0009:OMB #2060-0731, EPA ICR number 2607.02: Expires 1/31/2024]







Test Method
Name of Method: Total Sulfur in Liquid Aromatic Hydrocarbons and Their Derivatives by XRF
Laboratory Identification
Laboratory Name: USEPA National and Vehicle Fuels Emissions Laboratory/OAR
Laboratory Street Address: 2565 Plymouth Road, Mailcode AATSG
Laboratory City: Ann Arbor
Laboratory State: Michigan
Laboratory Zip code: 48105
Laboratory Contact Person: John Doe
Laboratory Contact Phone Number xxx-xxx-xxxx
Laboratory Contact Facsimile Number xxx-xxx-xxxx
Laboratory Contact E-mail Address [email protected]
1 to 10 ppm Accuracy Criterion - the arithmetic average of a continuous series of at least 10 tests performed on a commercially available gravimetric sulfur standard in the range of 1 to 10 ppm sulfur, say 10 ppm, shall not differ from the accepted reference value (ARV) of that standard by more than 0.4678725 ppm. Individual test results shall be compensated for any known chemical interferences.



Accuracy Criterion for 1-10 ppm




gravimetric sulfur standard




Is 1-10 ppm Sulfur Accuracy Criterion Met? PASSED




Arithmetic Average (ppm) 7.95




Vendor Name of Gravimetric Standard NIST




Lot Identification Number of Gravimetric Standard ALDS45680 Concentration QC Check on ARV



Accepted Reference Value (ARV) of Gravimetric Standard (ppm) 8.00 OK



Difference between Arithmetic Average and ARV of Gravimetric Standard 0.0515




Laboratory Test Identification Number Date Time Test Result (ppm) Data Entry QC Check on Test Result



######### 4/23/2021 8:00 AM 7.341 OK



######### 4/23/2021 8:05 AM 7.562 OK



######### 4/23/2021 8:10 AM 7.894 OK



######### 4/23/2021 8:15 AM 8.219 OK



######### 4/23/2021 8:20 AM 8.234 OK



######### 4/23/2021 8:25 AM 8.100 OK



######### 4/23/2021 8:30 AM 8.114 OK



######### 4/23/2021 8:35 AM 7.989 OK



######### 4/23/2021 8:40 AM 7.687 OK



######### 4/23/2021 8:45am 8.345 OK



File Typeapplication/vnd.openxmlformats-officedocument.spreadsheetml.sheet
File Modified0000-00-00
File Created0000-00-00