Form 5900-121 Fuel Marker Solvent Yellow 124 Precision Demonstration

Fuel Quality Regulations for Diesel Fuel Sold in 2001 & Later Years; for Tax-Exempt (Dyed) Highway Diesel Fuel; & Nonroad Locomotive & Marine Diesel Fuel (Renewal)

sy-124-templ-200706.xls

Performance-Based Test Method/Lab Qualification

OMB: 2060-0308

Document [ppt]
Download: ppt | pdf

Overview

SY124 Precision
SY124 Accuracy
EX - SY124 Precision
EX - SY 124 Accuracy


Sheet 1: SY124 Precision

Fuel Marker Solvent Yellow 124 Precision Demonstration [DFM001:OMB # 2060-0566 Expires 3/31/2009]
Test Method
Name of Method:
Organization ID No.(as in ASTM D XXXX-XX):
Laboratory Identification
Laboratory Name:
Laboratory Street Address:
Laboratory City:
Laboratory State:
Laboratory Zip code:
Laboratory Contact Person:
Laboratory Contact Phone Number:
Laboratory Contact Facsimile Number:
Laboratory Contact E-mail:
Confidential Business Information Claim. A company may assert a business confidentiality claim covering the information contained in this submission. If no such claim is made the information may be made available to the public by EPA without further notice. All questions of confidentiality will be handled pursuant to 40 CFR Part 2. Is confidentiality claimed for the information in this submission? (Note: Please answer by typing "Yes" or "No" in the adjacent cell.)
Fuel Marker Solvent Yellow 124 Precision Criterion - a standard deviation less than 0.10 milligrams per liter, computed from the results of a minimum of 20 repeat tests made over 20 days on samples taken from a single homogeneous commercially available diesel fuel which meets the applicable industry consensus and federal regulatory specifications and which contains the fuel marker solvent yellow 124 at a concentration in the range of 0.10 to 8 milligrams per liter. The 20 results must be a series of tests with a sequential record of the analyses and no omissions. A lab facility may exclude a given sample or test result only if the exclusion is for a valid reason under good laboratory practices and it maintains records regarding the sample and test results and the reason for excluding them.
Is fuel marker solvent yellow 124 Precision Criterion Met? REQUIRED DATA MISSING
standard deviation REQUIRED DATA MISSING
Laboratory Test Identification Number Date (mm/dd/yyyy) Time (hh:mm:ss am/pm) Test Result (mg/l) Data Entry QC Check on Test Result




DATA REQUIRED IN CELL D20




DATA REQUIRED IN CELL D21




DATA REQUIRED IN CELL D22




DATA REQUIRED IN CELL D23




DATA REQUIRED IN CELL D24




DATA REQUIRED IN CELL D25




DATA REQUIRED IN CELL D26




DATA REQUIRED IN CELL D27




DATA REQUIRED IN CELL D28




DATA REQUIRED IN CELL D29




DATA REQUIRED IN CELL D30




DATA REQUIRED IN CELL D31




DATA REQUIRED IN CELL D32




DATA REQUIRED IN CELL D33




DATA REQUIRED IN CELL D34




DATA REQUIRED IN CELL D35




DATA REQUIRED IN CELL D36




DATA REQUIRED IN CELL D37




DATA REQUIRED IN CELL D38




DATA REQUIRED IN CELL D39

Sheet 2: SY124 Accuracy

Fuel Marker Solvent Yellow 124 Accuracy Demonstration [DFM001:OMB # 2060-0566 Expires 3/31/2009]
Test Method


Name of Method: 0


Organization ID No.(as ASTM in D XXXX-XX): 0


Laboratory Identification


Laboratory Name: 0


Laboratory Street Address: 0


Laboratory City: 0


Laboratory State: 0


Laboratory Zip code: 0


Laboratory Contact Person: 0


Laboratory Contact Phone Number: 0


Laboratory Contact Facsimile Number: 0


Laboratory Contact E-mail Address: 0


Confidential Business Information Claim. A company may assert a business confidentiality claim covering the information contained in this submission. If no such claim is made the information may be made available to the public by EPA without further notice. All questions of confidentiality will be handled pursuant to 40 CFR Part 2. Is confidentiality claimed for the information in this submission? (Note: Please answer by typing "Yes" or "No" in the adjacent cell.)



0.10 to 1 milligrams per liter Accuracy Criterion - the arithmetic average of a continuous series of at least 10 tests performed on a commercially available fuel marker solvent yellow 124 standard in the range of 0.10 to 1 milligrams per liter shall not differ from the accepted reference value (ARV) of that standard by more than 0.05 milligrams per liter. Individual test results shall be compensated for any known chemical interferences.

4 to 10 milligrams per liter Accuracy Criterion - the arithmetic average of a continuous series of at least 10 tests performed on a commercially available fuel marker solvent yellow 124 standard in the range of 4 to 10 milligrams per liter shall not differ from the accepted reference value (ARV) of that standard by more than 0.05 milligrams per liter. Individual test results shall be compensated for any known chemical interferences.
Accuracy Criterion for 0.10-1 mg/l


Accuracy Criterion for 4-10 mg/l
fuel marker solvent yellow 124 standard


fuel marker solvent yellow 124 standard
Is 0.10-1 mg/l fuel marker solvent yellow 124 Accuracy Criterion Met? REQUIRED DATA MISSING


Is 4-10 mg/l fuel marker solvent yellow 124 Accuracy Criterion Met? REQUIRED DATA MISSING
Arithmetic Average (mg/l) REQUIRED DATA MISSING


Arithmetic Average (ppm) REQUIRED DATA MISSING
Name of Standard Vendor



Name of Standard Vendor

Lot Identification Number of Standard
Concentration QC Check on ARV

Lot Identification Number of Standard
Concentration QC Check on ARV
Accepted Reference Value (ARV) of standard (mg/l)
ARV TOO LOW IN CONCENTRATION

Accepted Reference Value (ARV) of Standard (mg/l)
ARV TOO LOW IN CONCENTRATION
Difference between Arithmetic Average and ARV of Standard REQUIRED DATA MISSING


Difference between Arithmetic Average and ARV of Standard REQUIRED DATA MISSING
Laboratory Test Identification Number Date (mm/dd/yyyy) Time (hh:mm:ss am/pm) Test Result (mg/l) Data Entry QC Check on Test Result

Laboratory Test Identification Number Date (mm/dd/yyyy) Time (hh:mm:ss am/pm) Test Result (mg/l) Data Entry QC Check on Test Result




DATA REQUIRED IN CELL D26





DATA REQUIRED IN CELL J26




DATA REQUIRED IN CELL D27





DATA REQUIRED IN CELL J27




DATA REQUIRED IN CELL D28





DATA REQUIRED IN CELL J28




DATA REQUIRED IN CELL D29





DATA REQUIRED IN CELL J29




DATA REQUIRED IN CELL D30





DATA REQUIRED IN CELL J30




DATA REQUIRED IN CELL D31





DATA REQUIRED IN CELL J31




DATA REQUIRED IN CELL D32





DATA REQUIRED IN CELL J32




DATA REQUIRED IN CELL D33





DATA REQUIRED IN CELL J33




DATA REQUIRED IN CELL D34





DATA REQUIRED IN CELL J34




DATA REQUIRED IN CELL D35





DATA REQUIRED IN CELL J35

Sheet 3: EX - SY124 Precision

Fuel Marker Solvent Yellow 124 Precision Demonstration [DFM001:OMB # 2060-0566 Expires 3/31/2009]
Test Method
Name of Method: Visible Spectrophotometer
Organization ID No.(as in ASTM D XXXX-XX): ASTM D XXXX-XX
Laboratory Identification
Laboratory Name: USEPA National and Vehicle Fuels Emissions Laboratory/OAR
Laboratory Street Address: 2565 Plymouth Road, Mailcode AATSG
Laboratory City: Ann Arbor
Laboratory State: Michigan
Laboratory Zip code: 48105
Laboratory Contact Person: Joe Sopata
Laboratory Contact Phone Number: 202-343-9034
Laboratory Contact Facsimile Number: 202-343-2801
Laboratory Contact E-mail Address: [email protected]
Confidential Business Information Claim. A company may assert a business confidentiality claim covering the information contained in this submission. If no such claim is made the information may be made available to the public by EPA without further notice. All questions of confidentiality will be handled pursuant to 40 CFR Part 2. Is confidentiality claimed for the information in this submission? (Note: Please answer by typing "Yes" or "No" in the adjacent cell.) No
Fuel Marker Solvent Yellow 124 Precision Criterion - a standard deviation less than 0.10 milligrams per liter, computed from the results of a minimum of 20 repeat tests made over 20 days on samples taken from a single homogenous commercially available diesel fuel which meets the applicable industry consensus and federal regulatory specifications and which contains the fuel marker solvent yellow 124 at a concentration in the range of 0.10 to 8 milligrams per liter. The 20 results must be a series of tests with a sequential record of the analyses and no omissions. A lab facility may exclude a given sample or test result only if the exclusion is for a valid reason under good laboratory practices and it maintains records regarding the sample and test results and the reason for excluding them.
Is fuel marker solvent yellow 124 Precision Criterion Met? PASSED
standard deviation 0.06
Laboratory Test Identification Number Date Time Test Result (mg/l) Data Entry QC Check on Test Result
######### 10/26/2006 8:00 AM 4.000 OK
######### 10/27/2006 8:01 AM 4.030 OK
######### 10/28/2006 8:20 AM 3.999 OK
######### 10/29/2006 8:23 AM 3.998 OK
######### 10/30/2006 9:00 AM 3.905 OK
######### 11/1/2006 9:10 AM 4.040 OK
######### 11/2/2006 9:20 AM 4.101 OK
######### 11/3/2006 9:30 AM 4.000 OK
######### 11/5/2006 9:40 AM 4.000 OK
######### 11/6/2006 9:50 AM 4.100 OK
######### 11/7/2006 10:00 AM 4.009 OK
######### 11/8/2006 10:10 AM 4.080 OK
######### 11/9/2006 10:20 AM 4.101 OK
######### 11/10/2006 10:30 AM 3.987 OK
######### 11/11/2006 10:40 AM 3.995 OK
######### 11/12/2006 10:50 AM 4.005 OK
######### 11/13/2006 11:00 AM 3.901 OK
######### 11/14/2006 11:10 AM 4.101 OK
######### 11/15/2006 11:20 AM 4.009 OK
######### 11/16/2006 11:30 AM 4.090 OK

Sheet 4: EX - SY 124 Accuracy

Fuel Marker Solvent Yellow 124 Accuracy Demonstration [DFM001:OMB # 2060-0566 Expires 3/31/2009]
Test Method


Name of Method: Visible Spectrophotometer


Organization ID No.(as in ASTM D XXXX-XX): ASTM D XXXX-XX


Laboratory Identification


Laboratory Name: USEPA National and Vehicle Fuels Emissions Laboratory/OAR


Laboratory Street Address: 2565 Plymouth Road, Mailcode AATSG


Laboratory City: Ann Arbor


Laboratory State: Michigan


Laboratory Zip code: 48105


Laboratory Contact Person: Joe Sopata


Laboratory Contact Phone Number 202-343-9034


Laboratory Contact Facsimile Number 202-343-2801


Laboratory Contact E-mail Address [email protected]


Confidential Business Information Claim. A company may assert a business confidentiality claim covering the information contained in this submission. If no such claim is made the information may be made available to the public by EPA without further notice. All questions of confidentiality will be handled pursuant to 40 CFR Part 2. Is confidentiality claimed for the information in this submission? (Note: Please answer by typing "Yes" or "No" in the adjacent cell.) No


0.10 to 1 milligrams per liter Accuracy Criterion - the arithmetic average of a continuous series of at least 10 tests performed on a commercially available fuel marker solvent yellow 124 standard in the range of 0.10 to 1 milligrams per liter shall not differ from the accepted reference value (ARV) of that standard by more than 0.05 milligrams per liter. Individual test results shall be compensated for any known chemical interferences.

4 to 10 milligrams per liter Accuracy Criterion - the arithmetic average of a continuous series of at least 10 tests performed on a commercially available fuel marker solvent yellow 124 standard in the range of 4 to 10 milligrams per liter shall not differ from the accepted reference value (ARV) of that standard by more than 0.05 milligrams per liter. Individual test results shall be compensated for any known chemical interferences.
Accuracy Criterion for 0.10-1 mg/l


Accuracy Criterion for 4-10 mg/l
fuel marker solvent yellow 124 standard


fuel marker solvent yellow 124 standard
Is 0.10-1 mg/l fuel marker solvent yellow 124 Accuracy Criterion Met? PASSED


Is 4-10 mg/l fuel marker solvent yellow 124 Accuracy Criterion Met? PASSED
Arithmetic Average (mg/l) 0.50


Arithmetic Average (ppm) 8.02
Name of Standard Vendor United Color Manufacturing


Vendor Name of Standard United Color Manufacturing
Lot Identification Number of Standard FMSY124101006 Concentration QC Check on ARV

Lot Identification Number of Standard FMSY124101008 Concentration QC Check on ARV
Accepted Reference Value (ARV) of standard (mg/l) 0.5 OK

Accepted Reference Value (ARV) of Standard (mg/l) 8 OK
Difference between Arithmetic Average and ARV of Standard 0.0011


Difference between Arithmetic Average and ARV of Standard 0.0153
Laboratory Test Identification Number Date Time Test Result (mg/l) Data Entry QC Check on Test Result

Laboratory Test Identification Number Date Time Test Result (mg/l) Data Entry QC Check on Test Result
######### 1/13/2005 8:00 AM 0.499 OK

######### 1/14/2005 8:00 AM 7.950 OK
######### 1/13/2005 8:30 AM 0.489 OK

######### 1/14/2005 8:30 AM 7.957 OK
######### 1/13/2005 9:00 AM 0.498 OK

######### 1/14/2005 9:00 AM 7.888 OK
######### 1/13/2005 9:30 AM 0.500 OK

######### 1/14/2005 9:30 AM 8.002 OK
######### 1/13/2005 10:00 AM 0.510 OK

######### 1/14/2005 10:00 AM 8.004 OK
######### 1/13/2005 10:30 AM 0.520 OK

######### 1/14/2005 10:30 AM 8.123 OK
######### 1/13/2005 11:00 AM 0.488 OK

######### 1/14/2005 11:00 AM 8.200 OK
######### 1/13/2005 11:30 AM 0.495 OK

######### 1/14/2005 11:30 AM 8.005 OK
######### 1/13/2005 12:00 PM 0.511 OK

######### 1/14/2005 12:00 PM 8.101 OK
######### 1/13/2005 12:30 PM 0.501 OK

######### 1/14/2005 12:30 PM 7.923 OK
File Typeapplication/vnd.ms-office
File Modified2007-05-09
File Created2004-11-04

© 2024 OMB.report | Privacy Policy