Regulations and Related Reporting and Recording Requirements - Packers and Stockyards Programs-Business

Regulations and Related Reporting and Recording Requirements - Packers and Stockyards Programs

P&SP4200-i

Regulations and Related Reporting and Recording Requirements - Packers and Stockyards Programs-Business

OMB: 0580-0015

Document [doc]
Download: doc | pdf

Instructions to Complete

Livestock Scale Test Report

Form P&SP-4200


The scale inspector or person testing the scale must complete form P&SP-4200 to document the scale tests required by the Packers and Stockyards Program.


Mail the completed form to the regional office of the Packers and Stockyards Program as listed below. The states covered by each regional office are listed below its address.

Regional Offices of the Packers and Stockyards Program

Grain Inspection, Packers and Stockyards Administration

Eastern Regional Office

Suite 230

75 Spring Street

Atlanta, GA 30303-3308

Telephone: (404) 562-5840

FAX: (404) 562-5848

e-mail: [email protected]

Western Regional Office

3950 Lewiston St., Suite 200

Aurora, CO 80011-1556

Telephone: (303) 375-4240

FAX: (303) 371-4609

e-mail: [email protected]

Midwestern Regional Office

Room 317

210 Walnut Street

Des Moines, IA 50309-2110

Telephone: (515) 323-2579

FAX: (515) 323-2590

e-mail: [email protected]

States Covered

States Covered

States Covered

AL, AR, CT, DC, DE, FL, GA, LA, MA, MD, ME, MS, NC, NH, NJ, NY, PA, RI, SC, TN, VA, VT, WV

AK, AZ, CA, CO, HI, ID, KS, MT, NM, NV, OK, OR, TX, UT, WA, WY

IA, IL, IN, KY, OH, MI, MO, MN, ND, NE, SD, WI


For more information, see Instructions for Testing Livestock and Animal Scales available from a regional office or via our web site at http://www.usda.gov/gipsa/pubs/live.pdf.


If you have any questions regarding this form, please contact the appropriate regional office of the Packers and Stockyards Program listed above.


NOTE: Explanations of terms and abbreviations are provided on page 2 of the form.


Line No.

Subject

Instruction

1

Page Number

The page number is normally 1 of 1. If additional space is needed or when testing multiple indicator/platform installations, number pages identifying the current page number and the total number of pages. For example, page 2 of 3.

2

Scale Test Agency

Enter the name, address, city, state, zip code, phone number, and e-mail address of the scale test agency.

3-7

Scale Owner

Enter the name of the scale owner and the address, city, county, and state where the scale is located. (Directional addresses may be helpful in rural locations. Attach a separate sheet to the form to provide directions.)

8

Scale Manufacturer

Enter the name of the manufacturer of the beam, dial or digital indicator

9

Model Number

Enter the model number of the indicator from the manufacturer’s ID plate.

10

Serial Number

Enter the serial number of the indicator found on the ID plate.

11

Type Indictor

Check the appropriate box to indicate the type of indicator and check the printer box if it has printing capabilities.

12

Balance Indicator

Enter the name of the manufacturer of the balance indicator installed on beam scales.

13

Pit Depth

If indicator is below ground, enter depth of pit in feet.

14

Lever Type

Enter the type or design of the lever system or load cell. (For example: “S” or straight; “A” or truss; pipe; pipe and load cell; 4-cells; 6-cells.)

15

Scale Capacity

Enter the total scale capacity (maximum nominal capacity), in pounds.

16

Scale Division

Enter the minimum scale division quantity, in pounds.

17

Class of Scale

Check the appropriate box to indicate if the scale is non-marked, or marked III or III L. NOTE: The scale may be marked as both III and III L.

18-19

Platform Size and Capacity

First: Inside the rack, measure and enter the length and the width of the platform in meters or feet; indicate which measurement (for example, feet) is used. Enter the length x width in line 18.

Second: Multiply the length times the width to determine the size of the platform.

Third: Use the following chart with the platform size to determine the capacity. See the example following the chart. Enter the scale capacity in line 19.


Livestock Scales Capacity

Category of Livestock

1 square meter

1 square foot

Cattle

540 kg

110 lbs

Hogs and Calves

340 kg

70 lbs

Sheep and Lambs

240 kg

50 lbs


Examples:

Platform size – length: 4 m. width: 2.5 m.

4m x 2½m = 10 m²

10 x 540 kg = 5,400 kg Capacity


Platform size – length: 14 ft. width: 8 ft.

14’ x 8’ = 112 sq. ft.

112 x 110 lb = 12, 320 lbs Capacity


Line No.

Subject

Instruction

20

Species Weighed

Enter the category of livestock that are weighed. (For example, steers, heifers, cows, bulls, calves, hogs, sheep, goats, horses, and mules.)

21

Accessories

Check the appropriate box to indicate each of the accessories that are part of the scale.

22

Access to Scale

Enter your observation and opinion as to access to the scale for testing.

23

Test Date

Enter the date (month, day, and year) you tested the scale.

24

Last Test Date

Enter the date (month, day, and year) the scale was last tested.

25

Condition of Parts of the Scale

Enter the housekeeping and maintenance condition of the scale. Specify the condition for the (1) gates and racks, (2) scale deck, and (3) scale pit.

26

Test Results

The State official or the scale company that conducted the test enters the test results.

Test Data

27

Sensitivity Response

Enter the Sensitivity Response (SR) on beam scales, or the discrimination on dial and digital scales, in pounds, at zero and maximum test loads.

28

Motion Detection

Enter the range in pounds (plus – minus) at which motion detection prevents printing of weight values.

29

Auto Zero

Enter the range in pounds (plus – minus) at which the scale will automatically reset to zero after minor balance changes.

30a-e

Test Data

It is important that you fill out the test report in the sequence and in the manner you conduct the test. If you begin a test and determine that the scale is defective, and then correct the defective condition, record this in sequence on the test report. Enter each of the following in the respective columns:

Column Enter Test Data

  1. The location or position on the platform of the test weights.

  2. The total amount of test weights on the scale, in pounds.

  3. The amount of correction weights, in pounds, used to balance the scale at zero load.

  4. On beam scales: the amount of error weights, in pounds, added or removed, to balance the scale. On dial and digital scales: the indicated or printed weight.

  5. Subtract column 4 from column 3; enter the amount, in pounds, as the error.

31

Decreasing Load Test and Balance

For dial and digital scales only, enter the test data for the decreasing load test and the resulting balance. It is important that you fill out the test report in the sequence and in the manner you conduct the test. If you begin a test and determine that the scale is defective, and then correct the defective condition, record this in sequence on the test report. Enter each of the following in the respective columns:

Column Enter Test Data

  1. The location or position on the platform of the test weights.

  2. The total amount of test weights on the scale, in pounds.

  3. The amount of correction weights, in pounds, used to balance the scale at zero load.

  4. On beam scales: the amount of error weights, in pounds, added or removed, to balance the scale. On dial and digital scales: the indicated or printed weight.

  5. Subtract column 4 from column 3; enter the amount, in pounds, as the error.

On the balance line, enter the amount the scale indicated after the test.

32

Remarks

Use the “Remarks” section to enter needed explanations, comments, adjustments you made, recommendations needed to correct a defective condition, etc.

33

Receipt Signature

The owner or responsible person must sign the form acknowledging receipt of a copy of the test report form.

34

Inspector Signature

The scale inspector or person(s) testing the scale must sign the test report form.


P&SP-4200-i August 2007 Page 3 of 3


File Typeapplication/msword
File TitleINSTRUCTIONS FOR COMPLETING FORM PSP-216
AuthorGipsaITS
Last Modified Bycmgrasso
File Modified2008-09-09
File Created2007-07-25

© 2024 OMB.report | Privacy Policy