StatA

CFR-2011-title46-vol4-part109.pdf

Display of Fire Control Plans for Vessels

StatA

OMB: 1625-0033

Document [pdf]
Download: pdf | pdf
Pt. 109

46 CFR Ch. I (10–1–11 Edition)

(iv) Keeping order in the passageways
and on the stairways and generally
controlling the movements of the visitors and other persons on board;
(8) Each muster list must specify substitutes for key persons if they are disabled, taking into account that different emergencies require different actions.
(c) Emergency instructions. Illustrations and instructions in English and
any other appropriate language, as determined by the OCMI, must be posted
in each cabin used for persons who are
not members of the crew or industrial
personnel. They must be conspicuously
displayed at each muster station and in
other accommodation spaces to inform
personnel of—
(1) The fire and emergency signal;
(2) Their muster station;
(3) The essential actions they must
take in an emergency;
(4) The location of lifejackets, including child-size lifejackets;
(5) The method of donning lifejackets;
(6) If immersion suits are provided,
the location of the immersion suits;
and
(7) Fully illustrated instructions on
the method of donning immersion
suits.

Subpart C—Operation and Stowage of
Safety Equipment
109.301 Operational readiness, maintenance,
and inspection of lifesaving equipment.
109.323 Manning of survival craft and supervision.
109.329 Fire pumps.
109.331 Firehoses and hydrants.
109.333 Fire main cutoff valves.
109.334 Working over water.
109.335 Stowage of work vests.
109.337 Fireman’s outfit.
109.339 Location of fire axes.
109.347 Pilot boarding equipment.

Subpart D—Reports, Notifications, and
Records
REPORTS AND NOTIFICATIONS
109.411 Notice and reporting of casualty.
109.415 Retention of records after casualty.
109.419 Report of unsafe machinery.
109.421 Report of repairs to boilers and pressure vessels.
109.425 Repairs and alterations: Fire detecting and extinguishing equipment.
RECORDS

[CGD 84–069, 61 FR 25299, May 20, 1996, as
amended at 63 FR 52815, Oct. 1, 1998]

109.431 Logbook.
109.433 Logbook entries.
109.435 Record of fire fighting equipment inspection.
109.437 Crane record book.
109.439 Crane certificates.

PART 109—OPERATIONS

Subpart E—Emergency Signals

Subpart A—General
Sec.
109.101 Applicability.
109.103 Requirements of the International
Convention for Safety of Life at Sea,
1974.
109.105 Incorporation by reference.
109.107 Designation of master or person in
charge.
109.109 Responsibilities of master or person
in charge.
109.121 Operating manual.

Subpart B—Tests, Drills, and Inspections

wreier-aviles on DSK3TPTVN1PROD with CFR

109.223 Fire fighting equipment.
109.227 Verification of vessel compliance
with applicable stability requirements.

109.201 Steering gear, whistles, general
alarm, and means of communication.
109.203 Sanitation.
109.205 Inspection of boilers and machinery.
109.209 Appliances for watertight integrity.
109.211 Testing of emergency lighting and
power systems.
109.213 Emergency training and drills.

109.503

Emergency signals.

109.521
109.525
109.527

Cranes: General.
Cranes: Working loads.
Cranes: Operator designation.

Subpart F—Cranes

Subpart G—Miscellaneous
109.555 Propulsion boilers.
109.557 Flammable and combustible liquids:
Carriage.
109.559 Explosives and radioactive materials.
109.563 Posting of documents.
109.564 Maneuvering characteristics.
109.565 Charts and nautical publications.
109.573 Riveting, welding, and burning operations.
109.575 Accumulation of liquids on helicopter decks.
109.577 Helicopter fueling.
109.585 Use of auto pilot.

164

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00174

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

Coast Guard, DHS

§ 109.121

APPENDIX A TO PART 109—NAVIGATION AND
VESSEL INSPECTION CIRCULAR NO. 4–78—
INSPECTION AND CERTIFICATION OF EXISTING MOBILE OFFSHORE DRILLING UNITS
AUTHORITY: 43 U.S.C. 1333; 46 U.S.C. 3306,
6101, 10104; Department of Homeland Security Delegation No. 0170.1.

100 Barr Harbor Drive, West Conshohocken,
PA 19428–2959.
ASTM Adjunct F 1626, Symbols for Use in
Accordance with Regulation II–2/20 of the
1974 SOLAS Convention as amended PCN:
12–616260–01 (1996)—109.563

SOURCE: CGD 73–251, 43 FR 56828, Dec. 4,
1978, unless otherwise noted.

International Maritime Organization (IMO)

Subpart A—General

Publications Section, 4 Albert Embankment,
London, SE1 7SR United Kingdom.
Resolution A.654.(16), Graphical Symbols for
Fire Control Plans—109.563

§ 109.101

Applicability.

No unit may be operated unless it
complies with the regulations in this
part.
§ 109.103 Requirements of the International Convention for Safety of
Life at Sea, 1974.
No self-propelled unit of more than
500 gross tons may embark on an international voyage unless it is issued the
appropriate Convention certificate as
described in §§ 107.401 through 107.413 of
this subchapter.
§ 109.105

wreier-aviles on DSK3TPTVN1PROD with CFR

American Society for Testing and Materials
(ASTM)

Incorporation by reference.

(a) Certain material is incorporated
by reference into this part with the approval of the Director of the Federal
Register in accordance with 5 U.S.C.
552(a). To enforce any edition other
than that specified in paragraph (b) of
this section, the Coast Guard must
publish notice of change in the FEDERAL REGISTER and make the material
available to the public. All approved
material is on file at the U.S. Coast
Guard, Office of Design and Engineering Standards (CG–521), 2100 2nd St.
SW., Stop 7126, Washington, DC 20593–
7126 or at the National Archives and
Records Administration (NARA). For
information on the availability of this
material at NARA, call 202–741–6030, or
go
to:
http://www.archives.gov/
federallregister/
codeloflfederallregulations/
ibrllocations.html. All material is
available from the sources indicated in
paragraph (b) of this section.
(b) The material for incorporation by
reference in this part and the sections
affected are:

[CGD 95–028, 62 FR 51208, Sept. 30, 1997, as
amended by USCG 1998–4442, 63 FR 52191,
Sept. 30, 1998; USCG 1999–5151, 64 FR 67182,
Dec. 1, 1999; USCG–2009–0702, 74 FR 49233,
Sept. 25, 2009]

§ 109.107 Designation of master or person in charge.
The owner of a unit or his agent shall
designate an individual to be the master or person in charge of the unit.
§ 109.109 Responsibilities of master or
person in charge.
(a) The master or person in charge
shall—
(1) Ensure that the provisions of the
Certificate of Inspection are adhered
to; and
(2) Be fully cognizant of the provisions in the operating manual required
by § 109.121.
(b) Nothing in this subpart shall be
construed as limiting the master or
person in charge, at his own responsibility, from diverting from the route
prescribed in the Certificate of Inspection or taking such steps as he deems
necessary and prudent to assist vessels
in distress or for other emergency conditions.
§ 109.121 Operating manual.
(a) Each unit must have on board an
operating manual approved by the
Coast Guard as meeting the requirements of this section.
(b) The operating manual must be
available to, and written in a manner
that is easily understood by, the unit’s
operating personnel and include the
following:
(1) A table of contents and general
index.
(2) A general description of the unit,
including major dimensions, tonnages,

165

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00175

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

§ 109.121

46 CFR Ch. I (10–1–11 Edition)

dry bulk capacities, damage stability
standard to which designed, hook load
capacity, rotary table capacity, set
back load capacity, drilling derrick capacity, and the identification, the maximum deadweight in pounds and kilograms, and the rotor size in feet and
meters of the helicopter used for the
design of the helicopter deck.
(3) Limiting design data for each
mode of operation, including draft, air
gap, wave height, wave period, wind,
current, temperature, and other environmental factors.
(4) Instructions on the use of the stability data.
(5) Lightweight data with a comprehensive listing of the inclusions and
exclusions of semi-permanent equipment, together with guidance for the
routine recording of lightweight alterations.
(6) Information identifying the type,
location, and quantities of permanent
ballast.
(7) Hydrostatic curves or tables.
(8) The maximum allowable deck
loadings either listed or shown on a
plan.
(9) A capacity plan showing the capacities and the vertical, longitudinal,
and transverse centers of gravity of
tanks and bulk material stowage
spaces.
(10) Tank sounding tables or curves
showing capacities, the vertical, longitudinal, and transverse centers of gravity in graduated intervals, and the free
surface data of each tank.
(11) Stability information setting
forth the maximum allowable height of
the center of gravity in relation to
draft data, displacement, and other applicable parameters unique to the design of the unit to determine compliance with the intact and damage stability criteria.
(12) Examples of loading conditions
for each mode of operation and instructions for developing other acceptable
loading conditions.
(13) Information concerning the use
of any special crossflooding fitting for
each operating condition which, if
damage
occurs,
may
require
crossflooding for survival (surface
units only) and the location of any
valve that may require closure to prevent progressive flooding (all units).

(14) Guidance for preparing the unit
for the passage of a severe storm and
the specific actions and approximate
length of time to complete them or to
attain a designated level of preparedness.
(15) Guidance for operating the unit
while changing its mode of operation
and for preparing the unit to make a
move and, for self-elevating units in
the transit mode, information for preparing the unit to avoid structural
damage during heavy weather, including the positioning and securing of
legs, cantilever structures, and heavy
cargo or large equipment which might
shift position.
(16) A description of any inherent
operational limitations for each mode
of operation and for each change in
mode of operation.
(17) Guidance for the person in charge
to determine the cause of unexpected
list and trim before taking corrective
action.
(18) For column stabilized units, a description, a schematic diagram, and
guidance for the operation of the ballast system and of the alternate means
of ballast system operation, together
with a description of their limitations,
such as pump capacities at various angles of heel and trim.
(19) A description, a schematic diagram, and guidance for the operation of
the bilge system and of the alternate
means of bilge system operation, together with a description of their limitations, such as spaces not connected
to the bilge system.
(20) General arrangement plans showing the location of: Watertight and
weathertight compartments, and openings in the hull and structure; vents,
closures, and mechanical, ventilating,
and electrical emergency shutdowns;
flooding alarms and fire and gas detectors; and access to different compartments and decks.
(21) A list of emergency shutdowns
and guidance on restarting all mechanical, ventilating, and electrical equipment after activation of the emergency
shutdowns.
(22) Procedures for evacuating personnel from the unit.
(23) A plan showing the hazardous locations described in § 111.105–33 of this
chapter.

166

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00176

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

Coast Guard, DHS

§ 109.213

(24) A schematic diagram of the
emergency power system.
(Approved by the Office of Management and
Budget under control number 1625–0038)
[CGD 83–071, 52 FR 6979, Mar. 6, 1987; 52 FR
9383, Mar. 24, 1987, as amended by CGD 95–028,
62 FR 51208, Sept. 30, 1997; USCG–2006–25697,
71 FR 55746, Sept. 25, 2006]

Subpart B—Tests, Drills, and
Inspections
§ 109.201 Steering gear, whistles, general alarm, and means of communication.
The master or person in charge shall
ensure that—
(a) Steering gear, whistles, general
alarm bells, and means of communication between the bridge or control
room and the engine room on self propelled units are inspected and tested—
(1) Within 12 hours before getting
under way; and
(2) At least once each week if under
way or on station; and
(b) Whistles and general alarm bells
on all other units are inspected examined and tested at least once each
week.
§ 109.203

Sanitation.

(a) The master or person in charge
shall insure that the accommodation
spaces are in a clean and sanitary condition.
(b) The chief engineer, or engineer in
charge if no chief engineer is required,
shall insure that the engineering
spaces are in a clean and sanitary condition.
§ 109.205 Inspection of boilers and machinery.

wreier-aviles on DSK3TPTVN1PROD with CFR

The chief engineer or engineer in
charge, before he assumes charge of the
boilers and machinery of a unit shall
inspect the boilers and machinery,
other than industrial machinery, and
report to the master or person in
charge and the Officer in Charge, Marine Inspection, any parts that are not
in operating condition.
§ 109.209 Appliances for watertight integrity.
(a) Before getting underway, the
master or person in charge shall insure

that each appliance for watertight integrity is closed and watertight.
(b) If existing conditions warrant, the
master or person in charge may permit
appliances for watertight integrity to
be open while afloat.
§ 109.211 Testing of emergency lighting and power systems.
(a) The master or person in charge
shall insure that—
(1) Each emergency lighting and each
emergency power system is tested at
least once each week;
(2) Each emergency generator is tested at least once each month by operating it under load for at least 2 hours;
and
(3) Each storage battery for emergency lighting and power systems is
tested every six months under actual
connected load for a period of at least
2 hours.
(b) After the 2 hour test period required in paragraph (a)(3) of this section, the voltage values under load or
specific gravity of electrolyte must be
measured. Measured values must be extrapolated to approximate the values
that would result following a 12 hour
test period. The test must be extended
if a trend cannot be determined to
allow extrapolation. The capacity of
the battery corresponding to the extrapolated values of voltage or specific
gravity must be sufficient to supply
the actual connected load.
§ 109.213 Emergency
drills.

training

(a) Training materials. Abandonment
training material must be on board
each unit. The training material must
consist either of a manual of one or
more volumes, written in easily understood terms and illustrated wherever
possible, or audiovisual training aids,
or both as follows:
(1) If a training manual is used, a
copy must be made available to each
person on board the unit. If audiovisual
training aids are used, they must be incorporated into the onboard training
sessions described under paragraph (g)
of this section.
(2) The training material must explain, in detail—

167

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00177

Fmt 8010

and

Sfmt 8010

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

§ 109.213

46 CFR Ch. I (10–1–11 Edition)

(i) The procedure for donning lifejackets, immersion suits, and anti-exposure suits carried on board;
(ii) The procedure for mustering at
the assigned stations;
(iii) The procedure for boarding,
launching, and clearing the survival
craft and rescue boats;
(iv) The method of launching from
within the survival craft;
(v) The procedure for releasing from
launching appliances;
(vi) The method and use of water
spray systems in launching areas when
required for the protection of aluminum survival craft or launching appliances;
(vii) Illumination in launching area;
(viii) The use of all survival equipment;
(ix) The use of all detection equipment for the location of survivors or
survival craft;
(x) With illustrations, the use of
radio lifesaving appliances;
(xi) The use of sea anchors;
(xii) The use of engine and accessories;
(xiii) The recovery of survival craft
and rescue boats, including stowage
and securing;
(xiv) The hazards of exposure and the
need for warm clothing;
(xv) The best use of the survival craft
for survival;
(xvi) The methods of retrieval, including the use of helicopter rescue
gear (slings, baskets, stretchers), and
unit’s line throwing apparatus;
(xvii) The other functions contained
in the muster list and emergency instructions; and
(xviii) The instructions for emergency repair of the lifesaving appliances.
(b) Familiarity with emergency procedures. Each of the crew members and
industrial personnel with assigned
emergency duties on the muster list
must be familiar with their assigned
duties before working on the unit.
(c) Drills—general. (1) Drills must, as
far as practicable, be conducted as if
there were an actual emergency.
(2) Each of the crew members and industrial personnel must participate in
at least one abandonment drill and one
fire drill every month. Drills must take
place within 24 hours of a change in

crew or industrial personnel if more
than 25 percent of the persons on board
have not participated in an abandonment and fire drills on board the unit
in the previous month.
(3) Drills must be held before the unit
enters service for the first time after
modification of a major character, or
when a new crew is engaged.
(d) Abandonment drills. (1) Abandonment drills must include the following:
(i) Each drill must include summoning of industrial personnel and
crew to muster stations with the general alarm, followed by drill announcements on the public address or other
communication system, and ensuring
that all on board are made aware of the
order to abandon ship.
(ii) Each drill must include reporting
to stations and preparing for the duties
described in the muster list.
(iii) Each drill must include checking
that industrial personnel and crew are
suitably dressed.
(iv) Each drill must include checking
that lifejackets or immersion suits are
correctly donned.
(v) Each drill must include lowering
of at least one lifeboat after any necessary preparation for launching.
(vi) Each drill must include starting
and operating the lifeboat engine.
(vii) Each drill must include operating davits used for launching the liferafts.
(2) Different lifeboats must, as far as
practicable, be lowered in compliance
with the requirements of paragraph
(d)(1)(v) of this section at successive
drills.
(3) Each lifeboat must be launched
with its assigned operating crew
aboard, and maneuvered in the water
at least once every 3 months, during an
abandonment drill.
(4) As far as is reasonable and practicable, rescue boats other than lifeboats which are also rescue boats, must
be launched each month with their assigned crew aboard and maneuvered in
the water. In all cases this requirement
must be complied with at least once
every 3 months.
(5) If a unit is fitted with marine
evacuation systems, drills must include an exercising of the procedures
required for the deployment of such a
system up to the point immediately

168

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00178

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

Coast Guard, DHS

§ 109.213

preceding actual deployment of the
system. This aspect of drills should be
augmented by regular instruction
using the on board training aids. Additionally, members of the crew or industrial personnel assigned to duties involving the marine evacuation system
must be further trained by participation in a full deployment of a similar
system into water, either on board a
unit or ashore, at intervals normally
not longer than 2 years, but in no case
longer than 3 years.
(6) Emergency lighting for mustering
and abandonment must be tested at
each abandonment drill.
(7) On a unit carrying immersion
suits or anti-exposure suits, immersion
suits or anti-exposure suits must be
worn by crew members and industrial
personnel in at least one abandonment
drill in any three-month period. If
wearing the suit is impracticable due
to warm weather, the crew members
must be instructed on its donning and
use.
(e) Line-throwing appliance. A drill
must be conducted on the use of the
line-throwing appliance at least once
every 3 months. The actual firing of
the appliance is at the discretion of the
person in charge.
(f) Fire drills. (1) Fire drills must, as
far as practicable, be planned in such a
way that due consideration is given to
regular practice in the various emergencies that may occur depending on
the type of unit.
(2) Each fire drill must include—
(i) Reporting to stations, and preparing for the duties described in the
muster list for the particular fire emergency being simulated;
(ii) Starting of fire pumps and the
use of two jets of water to determine
that the system is in proper working
order;
(iii) Checking the fireman’s outfits
and other personal rescue equipment;
(iv) Checking the relevant communication equipment;
(v) Checking the operation of watertight doors, fire doors, and fire
dampers and main inlets and outlets of
ventilation systems in the drill area;
(vi) Checking the necessary arrangements for subsequent abandonment of
the unit; and

(vii) Simulated operation of remote
controls for stopping ventilation and
fuel supplies to machinery spaces.
(3) The equipment used during drills
must immediately be brought back to
its fully operational condition, and any
faults and defects discovered during
the drills must be remedied as soon as
possible.
(g) Onboard training and instruction.
(1) Except as provided in paragraph
(g)(2) of this section, onboard training
in the use of the unit’s lifesaving appliances, including survival craft equipment, and in the use of the unit’s fireextinguishing appliances must be given
to each member of the crew and industrial personnel as soon as possible but
not later than 2 weeks after they join
the unit.
(2) If crew or industrial personnel are
on a regularly scheduled rotating assignment to the unit, onboard training
in the use of the unit’s lifesaving appliances, including survival craft equipment, and in the use of the unit’s fireextinguishing appliances must be given
not later than 2 weeks after the time of
first joining the unit.
(3) The crew and industrial personnel
must be instructed in the use of the
unit’s fire-extinguishing appliances,
lifesaving appliances, and in survival
at sea at the same interval as the
drills. Individual instruction may cover
different parts of the unit’s lifesaving
and fire-extinguishing appliances, but
all the unit’s lifesaving and fire-extinguishing appliances, must be covered
within any period of 2 months.
(4) Crew and industrial personnel
must be given instructions which include, but are not limited to—
(i) The operation and use of the
unit’s inflatable liferafts;
(ii) The problems of hypothermia,
first aid treatment for hypothermia
and other appropriate first aid procedures;
(iii) The special instructions necessary for use of the unit’s lifesaving
appliances in severe weather and severe
sea conditions; and
(iv) The operation and use of fire-extinguishing appliances.
(5) Onboard training in the use of
davit-launched liferafts must take
place at intervals of not more than 4
months on each unit with davit-

169

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00179

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

§ 109.213

46 CFR Ch. I (10–1–11 Edition)

launched liferafts. Whenever practicable this must include the inflation
and lowering of a liferaft. If this liferaft is a special liferaft intended for
training purposes only, and is not part
of the unit’s lifesaving equipment, this
liferaft must be conspicuously marked.
(6) Each of the industrial personnel
without designated responsibility for
the survival of others on board, must
be instructed in at least—
(i) The emergencies which might
occur on that particular type of unit;
(ii) The consequences of panic;
(iii) The location and actuation of
fire alarm controls;
(iv) The location and proper method
of use of firefighting equipment;
(v) Fire precautions;
(vi) The types of all lifesaving appliances carried on the unit and proper
methods of using them, including—
(A) The correct method of donning
and wearing a lifejacket, and if provided an immersion suit;
(B) Jumping into the water from a
height while wearing a lifejacket and,
if provided, an immersion suit;
(C) How to board survival craft from
the unit and from the water;
(D) Operation and use of the unit’s
inflatable liferafts;
(E) Special instructions necessary for
use of the unit’s lifesaving appliances
in severe weather and severe sea conditions;
(F) Swimming while wearing a lifejacket; and
(G) Keeping afloat without a lifejacket.
(vii) Where appropriate, how to survive in the water—
(A) In the presence of fire or oil on
the water;
(B) In cold conditions; and
(C) If sharks may be present.
(viii) Problems of hypothermia, first
aid treatment for hypothermia and
other appropriate first aid procedures;
(ix) The need to adhere to the principles of survival; and
(x) The basic methods of boarding
helicopters.
(7) Each member of the crew and each
of the industrial personnel with designated responsibility for the survival
of others on board must be instructed
in at least the items covered in paragraph (g)(6) of this section, and—

(i) Methods of detection, isolation,
control, and extinguishing of fire;
(ii) Checking and maintaining fire
fighting equipment;
(iii) Marshaling of personnel; and
(iv) Abandonment of the unit, including—
(A) Launching survival craft;
(B) Getting survival craft quickly
and safely clear of the unit; and
(C) Righting a capsized survival
craft.
(v) Handling all survival craft and
their equipment, including—
(A) Checking and maintaining their
readiness for immediate use;
(B) Using equipment to the best advantage;
(C) Using the sea anchor;
(D) Remaining, as far as practicable,
in the general vicinity of the unit, well
clear of but not downwind of any hydrocarbons or fire;
(E) Recovering and, as far as practicable, caring for other survivors;
(F) Keeping a lookout;
(G) Operating equipment provided to
aid in the detection of the survival
craft by others, including radio distress
alerting and radio emergency procedures; and
(H) Making proper use of food and
drinking water and using protective
measures in survival craft such as
those for preventing exposure to cold,
sun, wind, rain, and sea, and for preventing seasickness.
(vi) Cautioning on the preservation of
body fluids and the dangers of drinking
seawater;
(vii) Transferring personnel from survival craft to helicopters or to work
boats;
(viii) Maintaining morale; and
(ix) Methods of helicopter rescue.
(h) Records. (1) When musters are
held, details of abandonment drills, fire
drills, other lifesaving appliances, and
onboard training must be recorded in
the unit’s official logbook. Logbook entries must include the following:
(i) Logbook entries must identify the
date and time of the drill, muster, or
training session.
(ii) Logbook entries must identify
the survival craft and fire-extinguishing equipment used in the drills.
(iii) Logbook entries must identify
the inoperative or malfunctioning

170

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00180

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

Coast Guard, DHS

§ 109.301

equipment and the corrective action
taken.
(iv) Logbook entries must identify
crew members and industrial personnel
participating in drills or training sessions.
(v) Logbook entries must identify the
subject of the onboard training session.
(2) If a full muster, drill, or training
session is not held at the appointed
time, an entry must be made in the
logbook stating the circumstances and
the extent of the muster, drill, or
training session held.
[CGD 84–069, 61 FR 25299, May 20, 1996, as
amended at 63 FR 52815, Oct. 1, 1998]

§ 109.223

Fire fighting equipment.

The master or person in charge shall
insure that each hand portable fire extinguisher, semi-portable fire extinguisher, and fixed fire-extinguishing
system is tested and inspected at least
once each twelve months.

wreier-aviles on DSK3TPTVN1PROD with CFR

§ 109.227 Verification of vessel compliance with applicable stability requirements.
(a) The master or person-in-charge
shall determine that the vessel complies with all applicable stability requirements in the vessel’s trim and
stability book, operating manual, stability letter, Certificate of Inspection,
and Load Line Certificate, as the case
may be, and then enter an attestation
statement of the verification in the log
book, at the following times:
(1) Prior to transitioning from the
transit condition to the operating condition;
(2) Prior to transitioning from the
operating condition to the transit condition;
(3) Prior to significant changes in
deck load or ballast;
(4) At other times as required by the
vessel’s trim and stability book or operating manual; and
(5) At all other times necessary to assure the safety of the vessel.
(b) When determining compliance
with applicable stability requirements
the vessel’s draft, trim, and stability
must be determined as necessary and
any stability calculations made in support of the determination must be retained on board the vessel for a one

month period or until a change of location, if shorter.
[CGD 89–037, 57 FR 41823, Sept. 11, 1992]

Subpart C—Operation and
Stowage of Safety Equipment
§ 109.301 Operational readiness, maintenance, and inspection of lifesaving equipment.
(a) Operational readiness. Except as
provided in § 109.301(b)(3), each lifesaving appliance must be in good working order and ready for immediate use
at all times when the unit is in operation.
(b) Maintenance. (1) The manufacturer’s instructions for onboard maintenance of lifesaving appliances must be
onboard and must include the following
for each appliance—
(i) Checklists for use when carrying
out the inspections required under
§ 109.301(e);
(ii) Maintenance and repair instructions;
(iii) A schedule of periodic maintenance;
(iv) A diagram of lubrication points
with the recommended lubricants;
(v) A list of replaceable parts;
(vi) A list of sources of spare parts;
and
(vii) A log for records of inspections
and maintenance.
(2) In lieu of compliance with paragraph (b)(1) of this section, The OCMI
may accept a planned maintenance
program that includes the items listed
in that paragraph.
(3) If lifeboats, rescue boats or rigid
liferafts are maintained and repaired
while the unit is in operation, there
must be a sufficient number of lifeboats and liferafts remaining available
for use to accommodate all persons on
board.
(c) Spare parts and repair equipment.
Spare parts and repair equipment must
be provided for each lifesaving appliance and component subject to excessive wear or consumption and that
needs to be replaced regularly.
(d) Weekly inspections and tests. (1)
Each survival craft, rescue boat, and
launching appliance must be visually
inspected to ensure its readiness for
use.

171

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00181

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

§ 109.301

46 CFR Ch. I (10–1–11 Edition)

(2) Each lifeboat engine and rescue
boat engine must be run ahead and
astern for a total of not less than 3
minutes, unless the ambient air temperature is below the minimum temperature required for starting the engine. During this time, demonstrations
should indicate that the gear box and
gear box train are engaging satisfactorily. If the special characteristics of
an outboard motor fitted to a rescue
boat would not allow the outboard
motor to be run other than with its
propeller submerged for a period of 3
minutes, the outboard motor should be
run for such period as prescribed in the
manufacturer’s handbook.
(3) The general alarm system must be
tested.
(e) Monthly inspections. (1) Each lifesaving appliance, including lifeboat
equipment, must be inspected monthly
using the checklists required under
paragraph (b) of this section to make
sure it is complete and in good working
order. A report of the inspection, including a statement as to the condition
of the equipment, must be recorded in
the unit’s official logbook.
(2) Each EPIRB and each SART other
than an EPIRB or SART in an inflatable liferaft, must be tested monthly.
The EPIRB must be tested using the
integrated test circuit and output indicator to determine that it is operative.
(f) Annual inspections. Annual inspection and repair must include the following:
(1) Each survival craft, except for inflatable liferafts, must be stripped,
cleaned, and thoroughly inspected and
repaired, as needed, at least once in
each year, including emptying and
cleaning each fuel tank, and refilling it
with fresh fuel.
(2) Each davit, winch, fall and other
launching appliance must be thoroughly inspected and repaired, as needed, once in each year.
(3) Each item of survival equipment
with an expiration date must be replaced during the annual inspection
and repair, if the expiration date has
passed.
(4) Each battery clearly marked with
an expiration date, that is used in an
item of survival equipment must be replaced during the annual inspection

and repair, if the expiration date has
passed.
(5) Except for a storage battery used
in a lifeboat or rescue boat, each battery without an expiration date that is
used in an item of survival equipment
must be replaced during the annual inspection and repair.
(g) Servicing of inflatable lifesaving appliances, inflated rescue boats, and marine evacuation systems. (1) Each inflatable lifesaving appliance and marine
evacuation system must be serviced—
(i) Within 12 months of its initial
packing; and
(ii) Within 12 months of each subsequent servicing, except when servicing
is delayed until the next scheduled inspection of the unit, provided the delay
does not exceed 5 months.
(2) Each inflatable lifejacket must be
serviced in accordance with servicing
procedures meeting the requirements
of part 160, subpart 160.176 of this chapter. Each hybrid inflatable lifejacket
must be serviced in accordance with
the owners manual and meet the requirements of part 160, subpart 160.077
of this chapter.
(3) An inflatable liferaft must be
serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with
servicing procedures meeting the requirements of part 160, subpart 160.151,
of this chapter—
(i) No later than the month and year
on its servicing sticker affixed under 46
CFR 160.151–57(n), except that servicing
may be delayed until the next scheduled inspection of the unit, provided
that the delay does not exceed 5
months; and
(ii) Whenever the container is damaged or the container straps or seals
are broken.
(4) Each inflated rescue boat must be
repaired and maintained in accordance
with the manufacturer’s instructions.
All repairs to inflated chambers must
be made at a servicing facility approved by the Commandant, except for
emergency repairs carried out on board
the unit.
(h) Periodic servicing of hydrostatic release units. Each hydrostatic release
unit, other than a disposable hydrostatic release unit, must be serviced—

172

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00182

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

Coast Guard, DHS

§ 109.323

(1) Within 12 months of its manufacture and within 12 months of each subsequent servicing, except when servicing is delayed until the next scheduled inspection of the unit, provided
the delay does not exceed 5 months;
and
(2) In accordance with repair and
testing procedures meeting the requirements of part 160, subpart 160.062 of
this chapter.
(i) Periodic servicing of launching appliances and release gear. (1) Launching
appliances must be serviced at the intervals recommended in the manufacturer’s instructions, or as set out in
the shipboard planned maintenance
program.
(2) Launching appliances must be
thoroughly examined at intervals not
exceeding 5 years and upon completion
of the examination, the launching appliance must be subjected to a dynamic
test of the winch brake.
(3) Lifeboat and rescue boat release
gear must be serviced at the intervals
recommended in the manufacturer’s instructions, or as set out in the planned
maintenance program.
(4) Lifeboat and rescue boat release
gear must be subjected to a thorough
examination by properly trained personnel familiar with the system at
each inspection for certification.
(5) Lifeboat and rescue boat release
gear must be operationally tested
under a load of 1.1 times the total mass
of the lifeboat when loaded with its full
complement of persons and equipment,
whenever overhauled, or at least once
every 5 years.
(j) Maintenance of falls. (1) Each fall
used in a launching appliance must be
turned end-for-end at intervals of not
more than 30 months and must be renewed when necessary due to deterioration or at intervals of not more than 5
years, whichever is earlier.
(2) As an alternative to paragraph
(j)(1) of this section, each fall may be
inspected annually and renewed whenever necessary due to deterioration or
at intervals of not more than 4 years,
whichever is earlier.
(k) Rotational deployment of marine
evacuation systems. In addition to or in
conjunction with the servicing intervals of marine evacuation systems required by paragraph (g)(1) of this sec-

tion, each marine evacuation system
must be deployed from the unit on a
rotational basis. Each marine evacuation system must be deployed at least
once every 6 years.
[CGD 84–069, 61 FR 25301, May 20, 1996, as
amended by CGD 85–205, 62 FR 35392, July 1,
1997; CGD 84–069, 63 FR 52816, Oct. 1, 1998;
USCG–2001–11118, 67 FR 58541, Sept. 17, 2002]

§ 109.323 Manning of
and supervision.

survival

(a) There must be a sufficient number
of trained persons on board the survival craft for mustering and assisting
untrained persons.
(b) There must be a sufficient number
of deck officers, able seamen, or certificated persons on board to operate the
survival craft and launching arrangements required for abandonment by the
total number of persons on board.
(c) There must be one person placed
in charge of each survival craft to be
used. The person in charge must—
(1) Be a deck officer, able seaman, or
certificated person. The OCMI, considering the number of persons permitted
on board, and the characteristics of the
unit, may permit persons practiced in
the handling and operation of liferafts
or inflatable buoyant apparatus to be
placed in charge of liferafts or inflatable buoyant apparatus;
(2) Have another person designated
second-in-command of each lifeboat
permitted to carry more than 40 persons. This person should be a deck officer, able seaman, or certificated person; and
(3) Have a list of the survival craft
crew and must see that the crewmembers are acquainted with their duties. The second-in-command of a lifeboat must also have a list of the lifeboat crew.
(d) There must be a person assigned
to each motorized survival craft who is
capable of operating the engine and
carrying out minor adjustments.
(e) The person in charge must make
sure that the persons required under
paragraphs (a), (b), and (c) of this section are equitably distributed among
the unit’s survival craft.
[CGD 84–069, 61 FR 25302, May 20, 1996]

173

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00183

Fmt 8010

craft

Sfmt 8010

Y:\SGML\223196.XXX

223196

§ 109.329

46 CFR Ch. I (10–1–11 Edition)

§ 109.329 Fire pumps.
The master or person in charge shall
insure that at least one of the fire
pumps required in § 108.415 is ready for
use on the fire main system at all
times.
§ 109.331 Firehoses and hydrants.
The master or person in charge shall
insure that—
(a) At least one length of firehose
with a combination nozzle is connected
to each fire hydrant required by this
subchapter, at all times, except that
during heavy weather a firehose in an
exposed location may be temporarily
removed from the fire hydrant and
stowed in an accessible, nearby location;
(b) A fire hose required by this subchapter is not used for any purpose
other than firefighting, fire drills, and
testing;
(c) Access to each fire hydrant is not
blocked;
(d) Each firehose, except a firehose
temporarily removed from an exposed
location, is stowed on a rack or reel required by this subchapter; and
(e) Each low velocity spray applicator for a fire hose nozzle is attached
to the nozzle or stowed next to the fire
hydrant to which the fire hose is attached.
§ 109.333 Fire main cutoff valves.
The master or person in charge shall
insure that each fire main cutoff valve
is open and sealed to prevent closing,
except that a cutoff valve may be
closed to protect the portion of the fire
main system on an exposed deck from
freezing.

wreier-aviles on DSK3TPTVN1PROD with CFR

§ 109.334 Working over water.
The master or person in charge shall
insure that each person working over
the water is wearing a life preserver or
a buoyant work vest.
§ 109.335 Stowage of work vests.
The master or person in charge shall
insure that no work vest is stowed
where life preservers are stowed.
§ 109.337 Fireman’s outfit.
The master or person in charge shall
insure that—

(a) At least 2 persons who are trained
in the use of the fireman’s outfit are on
board at all times; and
(b) Each fireman’s outfit and its
spare equipment is stowed in a separate and accessible location.
(c) A fireman’s outfit is not used for
any purpose other than fire fighting except as provided in § 108.703.
§ 109.339

Location of fire axes.

The master or person in charge shall
insure that the fire axes required in
§ 108.499 of this subchapter are located
in the enclosures for fire hoses marked
in accordance with § 108.633 of this subchapter, if the fire axes are not located
in plain view.
§ 109.347

Pilot boarding equipment.

(a) The master or person in charge
shall ensure that pilot boarding equipment is maintained as follows:
(1) The equipment must be kept clean
and in good working order.
(2) Each damaged step or spreader
step on a pilot ladder must be replaced
in kind with an approved replacement
step or spreader step, prior to further
use of the ladder. The replacement step
or spreader step must be secured by the
method used in the original construction of the ladder, and in accordance
with manufacturer instructions.
(b) The master or person in charge
shall ensure compliance with the following during pilot boarding operations:
(1) Only approved pilot boarding
equipment may be used.
(2) The pilot boarding equipment
must rest firmly against the hull of the
vessel and be clear of overboard discharges.
(3) Two man ropes, a safety line and
an approved lifebuoy with an approved
water light must be at the point of access and be immediately available for
use during boarding operations.
(4) Rigging of the equipment and embarkation/debarkation of a pilot must
be supervised in person by a deck officer.
(5) Both the equipment over the side
and the point of access must be adequately lit during night operations.
(6) If a pilot hoist is used, a pilot ladder must be kept on deck adjacent to

174

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00184

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

Coast Guard, DHS

§ 109.431

the hoist and available for immediate
use.
[CGD 79–032, 49 FR 25455, June 21, 1984]

Subpart D—Reports, Notifications,
and Records
REPORTS AND NOTIFICATIONS
§ 109.411 Notice and reporting of casualty.
The requirements for providing notice and reporting of marine casualties
are contained in Part 4 of this chapter.

wreier-aviles on DSK3TPTVN1PROD with CFR

[CGD 84–099, 52 FR 47536, Dec. 14, 1987]

§ 109.415 Retention of records after
casualty.
(a) The owner, agent, master, or person in charge of a unit for which a report of casualty is made under § 109.411
shall insure that all records maintained on the unit are retained on
board the unit for at least 3 months
after the report of casualty is made or
until advised by the Officer in Charge,
Marine Inspection, that records need
not be retained on board.
(b) The records which must be retained in accordance with paragraph
(a) of this section include:
(1) Rough and smooth deck log.
(2) Rough and smooth engine room
log.
(3) Tour reports.
(4) Bell books.
(5) Navigation charts in use at the
time of casualty.
(6) Navigation work books.
(7) Compass deviation cards.
(8) Gyrocompass records.
(9) Storage plans.
(10) Record of drafts.
(11) Notices to mariners.
(12) Radiograms sent and received.
(13) The radio log.
(14) Personnel list.
(15) Crane record book.
(c) The owner, agent, master, or person in charge shall, upon request, make
the records described in this section
available for examination by any Coast
Guard official authorized to investigate the casualty.
§ 109.419 Report of unsafe machinery.
If a boiler, unfired pressure vessel, or
other machinery on a unit is unsafe to

operate, the master or person in charge
shall report the existence of the unsafe
condition to the Officer in Charge, Marine Inspection.
§ 109.421 Report of repairs to boilers
and pressure vessels.
Before making repairs, except normal repairs and maintenance such as
replacement of valves or pressure seals,
to boilers or unfired pressure vessels in
accordance with § 50.05–10 of this chapter, the master or person in charge
shall report the nature of the repairs to
the Officer in Charge, Marine Inspection.
§ 109.425 Repairs and alterations: Fire
detecting and extinguishing equipment.
(a) Before making repairs or alterations, except for routine maintenance,
minor repairs, or emergency repairs or
alterations to fire detecting and extinguishing equipment, the master or person in charge must report the nature of
the repairs or alterations to the OCMI.
(b) When emergency repairs or alterations, other than minor emergency repairs, have been made to fire-detecting
or fire-extinguishing equipment, the
master or person in charge must report
the nature of the repairs or alterations
to the OCMI.
[CGD 84–069, 63 FR 52816, Oct. 1, 1998]

RECORDS
§ 109.431 Logbook.
(a) The master or person in charge of
a unit, that is required by 46 U.S.C.
11301 to have an official logbook, shall
maintain the logbook on Form CG–706.
When the voyage is completed, the
master or person in charge shall file
the logbook with the Officer in Charge,
Marine Inspection.
(b) The master or person in charge of
a unit that is not required by 46 U.S.C.
11301 to have an official logbook, shall
maintain, on board, an unofficial logbook for making the entries required
by this subpart. This logbook must be
retained on board until the unit’s next
reinspection or inspection for certification.
[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 95–028, 62 FR 51208, Sept. 30,
1997; USCG–1999–6216, 64 FR 53227, Oct. 1, 1999]

175

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00185

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

§ 109.433
§ 109.433

46 CFR Ch. I (10–1–11 Edition)
Logbook entries. 1

The master or person in charge shall
insure that the following applicable entries are made in the logbook required
by this subpart:
(a) The date of each test of the steering gear, whistle, general alarm, and
communications equipment and the
condition of the equipment.
(b) The time and date of each opening
and closing, while the unit is afloat, of
each required appliance for watertight
integrity not fitted with a remote operating control or alarm system and the
reasons for the action.
(c) The date of each test of emergency lighting and power systems and
the condition and performance of the
equipment.
(d) The logbook must include information on emergency training drills
required in § 109.213(h).
(e) Prior to getting underway, the
fore and aft drafts, the position of the
loadline marks in relation to the surface of the water, and the density of
the water in which the vessel is floating, if in fresh or brackish water.
(f) After loading and prior to getting
underway and at all other times necessary to assure the safety of the vessel, a statement verifying vessel compliance with applicable stability requirements as required by § 109.227.
(g) The date of each inspection of
each accommodation space.
(h) The date of each inspection required in § 109.573 if performed by the
master or person in charge.
[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 83–067, 49 FR 39162, Oct. 4,
1984; CGD 89–037, 57 FR 41824, Sept. 11, 1992;
CGD 84–069, 61 FR 25303, May 20, 1996]

§ 109.435 Record of fire fighting equipment inspection.

wreier-aviles on DSK3TPTVN1PROD with CFR

(a) The master or person in charge
shall ensure that a record of each test
and inspection required in § 109.223 is
maintained on board, until the unit is
reinspected or inspected for certification.
1 NOTE: 46 U.S.C. 11301 requires that certain
entries be made in an official logbook, in addition to the entries required by this section;
and 46 U.S.C. 11302 prescribes the manner of
making those entries.

(b) The record required in paragraph
(a) of this section must show—
(1) The date of each test and inspection;
(2) The number or other identification of each item of equipment tested
or inspected; and
(3) The name of the person, and the
company he represents if any, who conducts the test or inspection.
§ 109.437 Crane record book.
The master or person in charge shall
ensure that the following are maintained in a crane record book:
(a) Descriptive information which
will identify each crane including—
(1) The API name plate data required
by Section 11 of API Spec. 2C, Second
Edition, February 1972; and
(2) The rates load chart for each line
reeving and boom length which may be
utilized.
(b) Information required by Section 3
of the American Petroleum Institute
Recommended Practice for Operation and
Maintenance of Offshore Cranes, API RP
2D, First Edition (October 1972) with
supplement 1.
(c) Dates and results of frequent inspections and tests required in paragraph (b) of this section.
(d) Dates and results of periodic inspections and tests required in paragraph (b) of this section.
(e) Date and result of each rated load
test.
(f) Date and description of each replacement or renewal of wire rope,
hooks, and other load components.
(g) Date and description of each failure of the crane, or any component or
safety feature.
(h) Date and description of each repair to the crane structure, boom, or
equipment.
§ 109.439 Crane certificates.
The master or person in charge shall
insure that the following certificates
and records for each crane are maintained on the unit:
(a) Each certificate issued by a crane
certifying authority.
(b) Each record and original certificate, or certified copy of a certificate,
or manufacturers or testing laboratories, companies or organizations
for—

176

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00186

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

Coast Guard, DHS

§ 109.557

(1) Loose gear;
(2) Wire rope; and
(3) The annealing of wrought iron
gear.

Subpart E—Emergency Signals
§ 109.503 Emergency signals.
(a) Emergency stations signals are
established as follows:
(1) The signal to man emergency stations is a rapid succession of short
soundings of both the general alarm
bell and the whistle, if a whistle is installed, for a period of not less than 10
seconds.
(2) The signal to secure from emergency stations is the sounding of both
the general alarm bell and the whistle,
if a whistle is installed, three times.
(b) The abandon unit stations signals
are established as follows:
(1) The signal to man abandon unit
stations is a continuous sounding of
both the general alarm and the whistle,
if a whistle is installed.
(2) If whistle signals are used to direct the handling of lifeboats and
davit-launched liferafts, they must
be—
(i) One short blast to lower the lifeboats and davit-launched liferafts; and
(ii) Two short blasts to stop lowering
the lifeboats and davit-launched liferafts.
(3) The signal to secure from abandon
unit stations is the sounding of both
the general alarm bell and the whistle,
if a whistle is installed, three times.
[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 84–069, 61 FR 25303, May 20,
1996]

§ 109.527
tion.

Cranes:

Operator

§ 109.521 Cranes: General.
The master or person in charge shall
ensure that each crane is operated and
maintained in accordance with the API
Recommended Practice for Operation and
Maintenance of Offshore Cranes, API RP
2D, First Edition (Oct. 1972) with supplement 1.
§ 109.525 Cranes: Working loads.
The master or person in charge shall
ensure that tables indicating the maximum safe working loads for the var-

(a) The master or person in charge
shall designate, in writing, each crane
operator.
(b) The master or person in charge
shall ensure that only designated operators operate cranes.
(c) The master or person in charge
shall ensure that each designated operator is familiar with the provisions of
the API Recommended Practice for Operation and Maintenance of Offshore
Cranes, API RP 2D, First Edition (Oct.
1972) with supplement 1.

Subpart G—Miscellaneous
§ 109.555

Propulsion boilers.

The master or person in charge and
the engineer in charge shall ensure
that—
(a) Steam pressure does not exceed
that allowed by the certificate of inspection; and
(b) The safety valves, once set, are
not tampered with or made inoperative.
[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 95–028, 62 FR 51208, Sept. 30,
1997]

The master or person in charge shall
ensure that—
(a) Flammable and combustible liquids in bulk are not carried, except as
allowed by endorsement to the Certificate of Inspection;
(b) Portable tanks are handled and
stowed in accordance with subparts
98.30 and 98.33 of this chapter and the
provisions of 49 CFR parts 171 through
179 that apply to portable tanks; and
(c) Grades B and lower liquids are—
(1) Authorized, by the Commandant,
to be carried; and

177

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00187

designa-

§ 109.557 Flammable and combustible
liquids: Carriage.

Subpart F—Cranes

wreier-aviles on DSK3TPTVN1PROD with CFR

ious working angles of the boom, where
the boom is rated at varying capacities
depending on the radius, and the maximum and minimum radius at which
the boom may be safely used, are conspicuously posted near the controls and
are visible to the operator when working the crane.

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

§ 109.559

46 CFR Ch. I (10–1–11 Edition)

(2) Carried only in fixed independent
or integral tanks.
[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 84–043, 55 FR 37413, Sept. 11,
1990]

§ 109.559 Explosives and radioactive
materials.
Except as authorized by the master
or person in charge, no person may use
explosives or radioactive materials and
equipment on a unit.
§ 109.563 Posting of documents.
The master or person in charge shall
ensure that the following are posted
under glass in the pilot house or control center:
(a) General arrangement plans for
each deck showing—
(1) Each fire retardant bulkhead;
(2) Each fire detecting, manual
alarm, and fire extinguishing system;
(3) Each fire door;
(4) Each means of ingress to compartments; and
(5) Each ventilating system, including the location of each damper, fan,
and remote means of stopping the fans.
(6) For units constructed on or after
September 30, 1997, and for existing
units which have their plans redrawn,
the symbols used to identify the aforementioned details shall be in accordance with IMO Assembly resolution
A.654(16). The identical symbols can be
found in ASTM Adjunct F 1626 (incorporated by reference, see § 109.105).
(b) The stability letter issued by the
Coast Guard.
(c) Each SOLAS and Coast Guard certificate issued to the unit.

wreier-aviles on DSK3TPTVN1PROD with CFR

[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 95–028, 62 FR 51208, Sept. 30,
1997; USCG–2000–7790, 65 FR 58462, Sept. 29,
2000]

§ 109.564 Maneuvering characteristics.
(a) The master or person in charge of
each self-propelled unit of 1,600 gross
tons and over shall ensure that a maneuvering information fact sheet is
prominently displayed in the pilothouse.
(b) For surface type units, the maneuvering information in Subpart 97.19
of this chapter must be displayed.
(c) The maneuvering information requirements for column stabilized, self-

elevating, and other units of unusual
design will be specified on a case by
case basis.
§ 109.565 Charts and nautical publications.
The master or person in charge of a
self-propelled unit shall ensure that
the unit has the following adequate, up
to date, and appropriate items for the
intended voyage:
(a) Charts.
(b) Sailing directions.
(c) Coast pilots.
(d) Light lists.
(e) Notices to mariners.
(f) Tide Tables.
(g) Current Tables.
(h) All other nautical publications
necessary. 1
§ 109.573 Riveting, welding, and burning operations.
Except as allowed by this section—
(a) The master or person in charge
shall ensure that there is no riveting,
welding, or burning—
(1) In a fuel tank;
(2) On the boundary of a fuel tank;
(3) On pipelines, heating coils, pumps,
fittings, or other appurtenances connected to fuel tanks; or
(4) On the boundary of spaces adjacent to tanks carrying Grades A, B, or
C flammable liquids in bulk.
(b) The operations prohibited in paragraph (a) of this section may be allowed if—
(1) An inspection conducted in accordance with the ‘‘Standard for the
Control of Gas Hazards on Vessels to be
Repaired,’’ N.F.P.A. No. 306–1974, is
made—
(i) In ports or navigable waters of the
United States, its territories and possessions, by—
(A) A marine chemist certified by the
National Fire Protection Association;
or
(B) If a certified marine chemist is
not available, a person designated by
the Officer in Charge, Marine Inspection; or
(ii) In all other locations by—
(A) A marine chemist certified by the
National Fire Protection Association;
1 NOTE: For U.S. units in or on the navigable waters of the United States. See 33
CFR 164.33.

178

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00188

Fmt 8010

Sfmt 8010

Y:\SGML\223196.XXX

223196

Coast Guard, DHS

Pt. 109, App. A

(B) If a certified marine chemist is
not available, a person designated by
the Officer in Charge, Marine Inspection; or
(C) If the persons required in paragraphs (b)(1)(ii) (A) and (B) of this section are not available, the master or
person in charge; or a welding supervisor designated, in writing, by the
master or person in charge; and
(2) A certificate is issued by the person conducting the inspection stating—
(i) That he conducted the inspection
in accordance with the standard in
paragraph (b)(1) of this section;
(ii) The operations that may be conducted; and
(iii) A list of precautions to be followed during the operations;
(c) The master or person in charge
shall ensure that the precautions in
paragraph (b)(2)(iii) of this section are
followed.
§ 109.575 Accumulation of liquids on
helicopter decks.
The master or person in charge shall
ensure that no liquids are allowed to
accumulate on the helicopter decks.
§ 109.577 Helicopter fueling.
(a) The master or person in charge
shall designate persons to conduct helicopter fueling operations.
(b) Portable tanks are handled and
stowed in accordance with subparts
98.30 and 98.33 of this chapter and the
provisions of 49 CFR parts 171 through
179 that apply to portable tanks; and

wreier-aviles on DSK3TPTVN1PROD with CFR

[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 84–043, 55 FR 37413, Sept. 11,
1990]

§ 109.585 Use of auto pilot.
Except as provided in 33 CFR 164.15,
when the automatic pilot is used in
areas of high traffic density, conditions
of restricted visibility, and all other
hazardous navigational situations, the
master or person in charge shall ensure
that—
(a) It is possible to immediately establish manual control of the unit’s
steering;
(b) A competent person is ready at all
times to take over steering control;
and
(c) The changeover from automatic
to manual steering and vice versa is

made by, or under the supervision of,
the officer of the watch.
APPENDIX A TO PART 109—NAVIGATION
AND VESSEL INSPECTION CIRCULAR
NO. 4–78—INSPECTION AND CERTIFICATION OF EXISTING MOBILE OFFSHORE DRILLING UNITS
1. Purpose. To promulgate instructions for
the inspection and certification of existing
mobile offshore drilling units. This NVIC is
also being published as appendix A of 46 CFR
Subchapter IA.
2. Background. Mobile Offshore Drilling
Units are recognized internationally through
the Intergovernmental Maritime Consultative Organization as being a ‘‘special purpose ship’’ designed and operated to carry
out an industrial function at sea. Contemporary U.S. Vessel regulations in Title 46
CFR do not adequately cover the safety considerations which are unique to the hull and
structural designs, industrial equipment and
operating procedures incorporated in drilling
vessels. To provide appropriate and adequate
standards, the Coast Guard with the assistance of the National Offshore Operations Advisory Committee, and following the provisions of the Administrative Procedures Act,
developed Subchapter IA, Regulations for
Mobile Offshore Drilling Units, 46 CFR Parts
107–109 and amendments to 46 CFR Subchapters ‘‘F’’, Marine Engineering Regulations, and ‘‘J’’, Electrical Engineering Regulations. These regulations, published in FEDERAL REGISTER (43 FR 56788 December 4, 1978)
will apply to all units contracted for on or
after the effective date of the regulations.
3. Discussion. a. This NVIC elaborates the
‘‘grandfather provisions’’ of 46 CFR 107.211
and 107.215 in applying Subchapter IA to the
approximately 150 existing ocean-going U.S.
flag mobile offshore drilling units. ‘‘Existing’’ Mobile Offshore Drilling Units are those
vessels which have been contracted for before the effective date of the regulations including:
(1) Units in Service.
(2) Units under construction.
(3) Units contracted for which are to be
constructed and delivered prior to January 1,
1981.
b. Existing uncertificated mobile drilling
units of which there are approximately 92 of
the bottom bearing configuration, i.e., jackup and submersible types, have not previously been required to comply with vessel
inspection regulations. Some units have met
the load line requirements of Subchapter
‘‘E’’ for International Voyages. Many of the
older units are not classed by a classification
society. Bottom bearing units operating on
the Outer Continental Shelf of United States

179

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00189

Fmt 8010

Sfmt 8002

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

Pt. 109, App. A

46 CFR Ch. I (10–1–11 Edition)

have been required to meet the safety requirements of 33 CFR Subchapter ‘‘N’’ as artificial islands. On January 3, 1979, existing
bottom bearing units are subject to the
‘‘grandfather provisions’’ in § 107.211(c) of
Subchapter IA.
c. Existing certificated mobile offshore
drilling units, for the purposes of this NVIC,
are column-stabilized and ship-shape types
of which approximately 58 are currently certificated, or have made application for an
original Certificate of Inspection or intend
to make application for an original inspection for certification under 46 CFR Subchapter ‘‘I’’ on the basis of the unit being
contracted for prior to the effective date of
the new regulations. These units may continue to meet the structural, equipment, material and arrangement standards which
were applicable to the hull, engineering,
electrical and industrial systems when the
units were contracted for. In addition they
must meet the provisions of d.(1), d.(4)(d),
d.(7)(b), d.(8), d.(9), d.(10)(b), d.(11) and d.(12)
of paragraph 3 of this NVC in accordance
with § 107.215(c)(2) of Subchapter IA.
d.
Inspection
Provisions
for
Existing
Uncertificated Units. The intent of the
‘‘grandfather’’ provisions of this NVIC for existing uncertificated units is to ascertain
through inspection that the material condition of the unit and its equipment meet reasonable levels of safety. To this end, the following determinations will be made:
• The design, construction and arrangements of the hull, machinery electrical and
industrial systems do not reveal manifestly
unsafe aspects.
• There is no excessive deterioration of the
hull structure or equipment foundations.
• There are no intrinsic fire or explosion
hazards.
• There are no personnel hazards such as
unguarded moving machinery, potential
electrical shock conditions or lack of handrails.
• The unit is seaworthy and exhibits satisfactory stability.
(1) General. (a) Repairs and minor alterations to hull structure or equipment may be
made to the same standards as the original
installation. However, new installations or
major alterations which affect vessel or personnel safety shall meet the applicable
standards of Subchapter IA.
(b) Existing items of safety equipment not
meeting the applicable specifications or requirements set forth in Subchapter IA may
be continued in service as long as they are
maintained in good working order to the satisfaction of the OCMI. Such safety equipment and installations requiring extensive
repairs shall be replaced and shall meet the
applicable specifications and requirements of
Subchapter IA.
(c) The OCMI has discretion to accept alternatives or equivalents which meet the es-

tablished standards, and to give special consideration to departures from the regulations when it can be shown that special circumstances warrant such departures.
(2) Plan Submittal. (a) For units not classed
by the American Bureau of Shipping or other
recognized classification society, (see 46 CFR
108.109) the OCMI must have sufficient plans
and information submitted to him which will
describe such things as the unit’s size, construction, configuration, arrangement of
tanks, decks and spaces; and the machinery
and electrical installation. In addition, the
OCMI may require submittal of any additional data he considers necessary in order
to proceed with the original inspections.
(b) For units classed by the American Bureau of Shipping or other recognized classification society, the plans and information
described in Subchapter IA § 107.305 (a), (b),
(v), and (ii) and a general description of the
machinery and electrical installation shall
be submitted to the OCMI for information.
The OCMI may accept continued classification as proof of structural, mechanical, and
electrical sufficiency. However, the OCMI
may require additional plans and information if necessary.
(3) Hull Structure. (a) No structural changes
will be required unless manifestly unsafe
conditions exist.
(b) Existing uncertificated units must be
drydocked or have a special examination in
lieu of drydocking as required by 46 CFR,
107–261.
(c) Achievement of one compartment subdivision is not required where extensive
modification of the original design would be
necessary; however, watertight integrity of
the hull and structural boundaries must be
maintained. Bulkheads and decks designed
to be watertight must be maintained as such
where they are penetrated by pipes, electrical cable, reach rods, ventilation systems,
etc.
(4) Stability. (a) The stability of each existing unit will be reviewed by the Coast Guard.
The plans indicated in 46 CFR Subchapter IA
§ 107.305(q) through (u-l) must be submitted
to the cognizant OCMI or Merchant Marine
Technical Office.
(b) Lightship data from a Coast Guard witnessed and approved stability test is required
for each existing, uncertificated unit. Alternatively other evidence of lightship values
will be considered on a case by case basis.
(c) In general, compliance with the intact
stability standards of 46 CFR Subchapter IA,
§§ 108.303 through 108.309 is required. Where
existing units were designed to a lesser
standard of stability than that specified in
§§ 108.303 through 108.309, some relaxation
based on proven past performance may be
granted at the discretion of the OCMI and
limiting conditions, if any, set forth in the

180

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00190

Fmt 8010

Sfmt 8002

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

Coast Guard, DHS

Pt. 109, App. A

operating manual. In no case will the minimum wind speed for adequate stability be
reduced below 50 knots.
(d) An operating manual shall be prepared
for each unit. Each operating manual must
contain the information indicated in 46 CFR
Subchapter IA, § 109.121(d) and be submitted
to the cognizant OCMI or Merchant Marine
Technical Office for review.
(5) Load Line. (a) All units are required to
obtain and maintain a valid Load Line Certificate. The structure and stability of the
unit must be proven adequate for the voyages and areas of operation intended.
(b) The American Bureau of Shipping or
other recognized classification society will
issue Load Line Certificates and conduct initial and annual load line surveys. Coast
Guard and the American Bureau of Shipping
inspections may be conducted simultaneously, but it is the owner’s responsibility
to arrange coordinated inspection schedules.
(c) The structural review conducted by the
American Bureau of Shipping or other recognized classification society for load line assignment may be accepted by the Coast
Guard as proof of structural adequacy of the
hull.
(d) The stability review must be completed
prior to issuance of a Load Line Certificate.
The Coast Guard will inform the American
Bureau of Shipping or other recognized classification society of the results of the stability review, and will indicate any stability
limitations to be placed on the Load Line
Certificate.
(e) Freeboard calculations for self-elevating units with barge type hulls will be
made in accordance with 46 CFR, Part 42.
The bow height requirements of 46 CFR 42.20–
70 may be relaxed to approximately 33% of
the normal requirement for barge shapes
moving at speeds less than 6 knots. No relaxation of the addition to freeboard for deficiency in sheer is allowed. The freeboard for
units other than self-elevating units with
barge type hulls will be based upon compliance with the intact and damage stability
standards applicable at the time the unit
was contracted for.
(f) All units delivered after the date of this
NVIC regardless of contract date, must obtain a Load Line Certificate as soon as operationally feasible.
(6) Route and Operating Area Limitations. (a)
Units classed by the American Bureau of
Shipping or other recognized classification
society for ocean service generally will be
certificated by the Coast Guard for ocean
routes.
(b) Unclassed units which have proven
structural and stability adequacy by continued safe operation in a specific geographic
area, such as the Gulf of Mexico, will be limited by the Certificate of Inspection and
Load Line Certificate to that area. To qualify for an unlimited oceans route, such a

unit must be reviewed for adequacy of the
structure and stability by the Coast Guard
and meet the Load Line requirements of d.
(5) above.
(c) Any unit which intends to move or operate outside the geographical area indicated
on the Certificate of Inspection must receive
prior approval from the OCMI.
(7) Fire Protection. (a) Structural fire protection. All units must meet the provisions of
§ 108.123, Insulation of Combustible Materials
and § 108.127, Storage Lockers for Combustibles. All existing interior stairways which
are open at each end must be enclosed at one
level. On units where wood was utilized in
the construction of accommodation spaces,
each space must be equipped with a smoke or
heat detector either battery powered or operating on the AC power supply. All detectors
must have the Underwriters Laboratories,
Inc., label (UL) or the Factory Mutual Laboratories (FM) label.
(b) Fire Extinguishing Systems. Systems and
equipment must be provided which will meet
or be equivalent to the applicable specifications and provisions required by Subchapter
IA. Installed fire extinguishing systems,
which provide equivalent or greater protection than systems required by Subpart E,
Subchapter IA may be continued in use as
long as they are in good material condition
and will function as designed. Where practicable, existing washdown systems may be
utilized as the firemain. Where wood was utilized in the construction of accommodation
spaces, the applicable requirements of 46
CFR Subchapter IA, Table 108.495(a) should
be doubled.
(8) Lifesaving Equipment. (a) Each unit must
have lifesaving equipment (lifeboats and
davit launched liferafts) for 200 percent of
the total persons allowed on board. Except
for submersible type units, the installation
of lifeboats for 100 percent of the persons (on
board) is required in accordance with 46 CFR
108.503 of Subchapter IA. Consideration will
be given to those units where existing arrangement and structure do not provide sufficient room for installation of the lifeboats
or where the added weight of the lifeboats,
davits and winches will materially reduce
the variable load capacity of the unit. In
such cases, davit launched inflatable liferafts with a combined personnel capacity of
the required lifeboats, and a rescue boat approved by the OCMI may be acceptable
equivalents. Submersible type units may
substitute Coast Guard approved throw over
type inflatable liferafts and an approved rescue boat for the required lifeboats.
(b) For the second part of the total 200 percent primary lifesaving requirement, lifeboats installed in accordance with 33 CFR,
Subchapter ‘‘N’’ Part 144 or Coast Guard approved life floats may be retained as provided for in 3.d(1)(b) of this Circular. They
will be considered collectively with the

181

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00191

Fmt 8010

Sfmt 8002

Y:\SGML\223196.XXX

223196

wreier-aviles on DSK3TPTVN1PROD with CFR

Pt. 109, App. A

46 CFR Ch. I (10–1–11 Edition)

Coast Guard approved liferafts for calculating the amount of equipment to provide
for 100 percent of personnel on board.
(c) Adequate access to all lifesaving equipment must be provided.
(9) Cranes. (a) Plan approval will not normally be required of any crane which conforms to the specifications of the manufacturer as originally installed. A rated load
test as described in § 107.260 of Subchapter IA
will be required unless the crane has been
load tested while under certification by an
approved certifying authority as provided for
in 46 CFR 107.258. Prior to the rated load
test, the crane should be identified by manufacturer and model number to determine
that the correct load rating chart is being
used. The owner must submit to the OCMI
details and calculations of any alterations to
a crane which were accomplished without
manufacturer’s documentation in order to
verify the rated load of the crane.
(10) Electrical. (a) Multiple power sources do
not require an emergency generator; however, storage batteries or approved relaycontrolled battery operated lanterns are required to be installed for the emergency
lighting system and provide 12 hours of
lighting.
(b) Electrical equipment installed in Class
I, division 1 and 2 locations, as defined in
Subchapter IA, § 108.170 must be of a suitable
type and in good material condition.
(11) Unfired Pressure Vessels. (a) Unfired
pressure vessels built and stamped in accordance with Section VIII of the ASME Code
may be continued in service as long as they
remain in satisfactory condition. At the
original and subsequent inspections for certification, ASME Code pressure vessels must
be tested and examined in accordance with
the requirements in 46 CFR 61.10–5.
(b) Unfired pressure vessels which cannot
be identified as being constructed to any recognized standard may be continued in service provided that no obvious defects are
noted. These pressure vessels shall be
hydrostatically tested to one and one half
times the working pressure. For pressure
vessels
that
can
not
be
reasonably
hydrostatically tested, nondestructive testing may be used to verify the pressure vessels condition for continued serviceability.
These pressure vessels will then be stamped
with a Coast Guard identification number
and periodically tested and examined in accordance with the requirements in 46 CFR
61.10–5.
(12) Marine Sanitation Devices. (a) All units
must meet the provisions of 33 CFR Part 159,
Coast Guard Marine Sanitation Devices Regulations. The discharge requirements are
compatible with the OCS Orders of the U.S.
Geological Survey.
4. Action. a. The owner of each existing certificated unit must provide the cognizant
OCMI a proposed plan to accomplish the re-

quirements in paragraph 3. c. of this NVIC
within 60 days from the effective date of the
regulations. Most items should be approved
at the unit’s next inspection for certification; however, where major equipment installations are concerned, the owner may be
allowed up to two years to comply with the
requirements from the time the OCMI completes his assessment of the proposals.
b. Application for Original Inspection for Certification. Not later than sixty days from
January 3, 1979, application for original inspection for certification of all existing
uncertificated units, shall be submitted to the
appropriate OCMI. The plans or descriptive
data specified in paragraph 3.d(2) of this
NVIC along with a proposed plan to bring the
unit into compliance should, if possible, be
submitted with the application for inspection. If not feasible to assemble all required
information in this time frame, an estimated
date of submittal shall be indicated on the
application. Arrangements should be made
to commence the original inspection for certification with due consideration for the
unit’s operating situation.
c. To the extent possible the same inspection team will conduct the inspection of all
existing uncertificated units in a geographical area. It may be advantageous to
conduct the original inspection in conjunction with an impending special or periodic
survey, drydocking or availability period.
Units under construction will receive primary consideration by the OCMI for the allocation of time and personnel so that any
problems can be identified while the unit is
in the most advantageous situation to apply
corrections.
d. The variety of designs and arrangements
presented by existing uninspected MODU’s
makes it impractical to prescribe detailed
standards for all existing units. The procedures followed to implement this NVC must
provide the necessary flexibility. Items
which must be taken into consideration in
applying this NVIC are listed below. Categorizing units into groups to which the same
items apply will be of value during the inspection process. These items are:
• Type
• Builder
• Model
• Date build
• Classed by ABS or other classification
society
• Load Line assignment
• Operating
history
(including
geographical areas)
• Present location
e. Issuance of the Original Certificate of Inspection. The intent of the original inspection of existing uncertificated units is to identify and commence correction of any unsafe
conditions and/or equipment deficiencies and
to issue the unit an original Certificate of
Inspection. A reasonable period of time will

182

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00192

Fmt 8010

Sfmt 8002

Y:\SGML\223196.XXX

223196

Coast Guard, DHS

Pt. 109, App. A

wreier-aviles on DSK3TPTVN1PROD with CFR

be permitted to correct minor deficiencies.
Those items directly affecting personnel
safety and health will require immediate attention to correct the unsafe condition. Extensive deficiencies, such as those involving
structural aspects or equipment may require
up to two years to remedy. Additional times
may be allowed if repair facilities are not
available to coastal areas adjacent to the
unit’s area of operation. Where manifestly
unsafe conditions are found, the OCMI may

require that the unit discontinue operations
until such conditions are corrected. If the
owner or operator feels aggrieved by the decision of the OCMI, the appeals procedures of
46 CFR 2.01–70 are applicable.
f. Questions concerning this NVIC should
be referred to the Commandant (CG–543).
[CGD 73–251, 43 FR 56828, Dec. 4, 1978, as
amended by CGD 96–041, 61 FR 50730, Sept. 27,
1996; USCG–2009–0702, 74 FR 49233, Sept. 25,
2009]

183

VerDate Mar<15>2010

08:26 Nov 18, 2011

Jkt 223196

PO 00000

Frm 00193

Fmt 8010

Sfmt 8002

Y:\SGML\223196.XXX

223196


File Typeapplication/pdf
File Modified2014-08-14
File Created2014-08-14

© 2024 OMB.report | Privacy Policy